ASTM C652-2011 Standard Specification for Hollow Brick (Hollow Masonry Units Made From Clay or Shale)《空心砖(粘土或页岩制空心砌块)的标准规格》.pdf
《ASTM C652-2011 Standard Specification for Hollow Brick (Hollow Masonry Units Made From Clay or Shale)《空心砖(粘土或页岩制空心砌块)的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C652-2011 Standard Specification for Hollow Brick (Hollow Masonry Units Made From Clay or Shale)《空心砖(粘土或页岩制空心砌块)的标准规格》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C652 11Standard Specification forHollow Brick (Hollow Masonry Units Made From Clay orShale)1This standard is issued under the fixed designation C652; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specification covers hollow building br
3、ick andhollow facing brick made from clay, shale, fire clay, ormixtures thereof, and fired to incipient fusion. Four types ofhollow brick in each of two grades and two classes are covered.In this specification, the term hollow brick shall be understoodto mean hollow clay masonry units whose net cros
4、s-sectionalarea (solid area) in any plane parallel to the surface, containingthe cores, cells, or deep frogs, is less than 75 % of its grosscross-sectional area measured in the same plane (see 3.3). Thisspecification does not cover brick intended for use as pavingbrick (see Specification C902).1.2 T
5、he property requirements of this sspecification apply atthe time of purchase. The use of results from testing of brickextracted from masonry structures for determining confor-mance or nonconformance to the property requirements (Sec-tion 5) of this standard is beyond the scope of this specification.
6、1.3 Brick covered by this specification are manufacturedfrom clay, shale, or similar naturally occurring substances andsubjected to a heat treatment at elevated temperatures (firing).The heat treatment shall develop sufficient fired bond betweenthe particulate constituents to provide the strength an
7、d dura-bility requirements of this specification. (See “firing” and“firing bond” in Terminology C1232.)1.4 Hollow brick differ from unglazed structural clay tile(Specifications C34 and C212) and solid brick (SpecificationsC62 and C216). Hollow brick require greater shell and webthicknesses and highe
8、r minimum compressive strength thanstructural clay tile, but permit greater void area and lesserdistance from exposed edge to core hole than solid brick.Therefore, environmental and structural performance may bedifferent in elements constructed of hollow brick from thoseconstructed of structural cla
9、y tile or solid brick.1.5 The text of this specification references notes andfootnotes which provide explanatory material. These notes andfootnotes (excluding those in tables and figures) shall not beconsidered as requirements of the specification.1.6 The values stated in inch-pound units are to be
10、regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.2. Referenced Documents2.1 ASTM Standards:2C34 Specification for Structural Clay Load-Bearing WallTileC62 Specification for Building Bric
11、k (Solid Masonry UnitsMade From Clay or Shale)C67 Test Methods for Sampling and Testing Brick andStructural Clay TileC212 Specification for Structural Clay Facing TileC216 Specification for Facing Brick (Solid Masonry UnitsMade from Clay or Shale)C902 Specification for Pedestrian and Light Traffic P
12、avingBrickC1232 Terminology of MasonryE835/E835M Guide for Modular Coordination of Clay andConcrete Masonry Units33. Classification3.1 GradesTwo grades of hollow brick are covered:3.1.1 Grade SWHollow brick intended for use where ahigh and uniform degree of resistance to frost action anddisintegrati
13、on by weathering is desired and the exposure issuch that the hollow brick may be frozen when permeated withwater.3.1.2 Grade MWHollow brick intended for use where amoderate and somewhat nonuniform degree of resistance tofrost action is permissible or where they are unlikely to bepermeated with water
14、 when exposed to temperatures belowfreezing.1This specification is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.02 on Brick and Structural Clay Tile.Current edition approved Aug. 15, 2011. Published August 2011. Origina
15、llyapproved in 1970. Last previous edition approved in 2010 as C652 10. DOI:10.1520/C0652-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document
16、Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United
17、 States.3.2 TypesFour types of hollow brick are covered:3.2.1 Type HBSHollow brick for general use in masonry.3.2.2 Type HBXHollow brick for general use in masonrywhere a higher degree of precision and lower permissiblevariation in size than permitted for Type HBS is required.3.2.3 Type HBAHollow br
18、ick for general use in masonryselected to produce characteristic architectural effects resultingfrom nonuniformity in size and texture of the individual units.3.2.4 Type HBBHollow brick for general use in masonrywhere a particular color, texture, finish, uniformity, or limits oncracks, warpage, or o
19、ther imperfections detracting from theappearance are not a consideration.3.2.5 When the type is not specified, the requirements forType HBS shall govern.3.3 ClassTwo classes of hollow brick are covered:3.3.1 Class H40VHollow brick intended for use wherevoid areas or spaces greater than 25 %, but not
20、 greater than40 %, of the gross cross-sectional area of the unit measured inany plane parallel to the surface containing the cores, cells, ordeep frogs are desired. The void spaces, the web thicknesses,and the shell thicknesses shall comply with the requirements ofSection 9 on Coring and Frogging.3.
21、3.2 Class H60VHollow brick intended for use wherelarger void areas are desired. The sum of these void areas shallbe greater than 40 %, but not greater than 60 %, of the grosscross-sectional area of the unit measured in any plane parallelto the surface containing the cores, cells or deep frogs. Thevo
22、id spaces, the web thicknesses, and the shell thicknessesshall comply with the requirements of Section 9 on HollowSpaces and to the minimum requirements contained in Table 1(see Fig. 1).3.3.3 When the class is not specified, the requirements ofclass H40V shall govern.4. Materials and Manufacture4.1
23、The body of all hollow brick shall be of clay, shale, fireclay, or mixtures of these materials, with or without admix-tures, burned to meet the requirements of this specification.Any coloring or other materials added to the clay shall besuitable ceramic materials and shall be well distributedthrough
24、out the body.4.2 Colors and textures produced by application of inor-ganic coatings to the faces of the brick shall be permitted withthe consent of the purchaser, provided that evidence is fur-nished of the durability of the coatings. Brick that are coloredby flashing or textured by sanding, where t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6522011STANDARDSPECIFICATIONFORHOLLOWBRICKHOLLOWMASONRYUNITSMADEFROMCLAYORSHALE 空心砖 粘土 页岩 空心 砌块

链接地址:http://www.mydoc123.com/p-507892.html