ASTM C62-2008 Standard Specification for Building Brick (Solid Masonry Units Made From Clay or Shale).pdf
《ASTM C62-2008 Standard Specification for Building Brick (Solid Masonry Units Made From Clay or Shale).pdf》由会员分享,可在线阅读,更多相关《ASTM C62-2008 Standard Specification for Building Brick (Solid Masonry Units Made From Clay or Shale).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 62 08Standard Specification forBuilding Brick (Solid Masonry Units Made From Clay orShale)1This standard is issued under the fixed designation C 62; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specification covers brick intended fo
3、r both struc-tural and nonstructural masonry where external appearance isnot a requirement. The brick are prismatic units available in avariety of sizes, shapes, textures, and colors. The specificationdoes not cover brick intended for use as facing units or wheresurface appearance is a requirement,
4、(see Specification C 216).This specification does not cover brick intended for use aspaving brick (see Specification C 902).1.2 The property requirements of this standard apply at thetime of purchase. The use of results from testing of brickextracted from masonry structures for determining conform-a
5、nce or nonconformance to the property requirements (Section3) of this standard is beyond the scope of this standard.1.3 Brick are manufactured from clay, shale, or similarnaturally occurring earthy substances and subjected to a heattreatment at elevated temperatures (firing). The heat treatmentmust
6、develop sufficient fired bond between the particulateconstituents to provide the strength and durability requirementsof this specification. (See firing, fired bond, and incipientfusion in Terminology C43.)1.4 Brick are shaped during manufacture by molding, press-ing, or extrusion, and the shaping me
7、thod is a way to describethe brick (see Terminology C43).1.5 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.6 The values stated in in
8、ch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.2. Referenced Documents2.1 ASTM Standards:2C43 Terminology of Structural Clay ProductsC67 Test Methods for Sampl
9、ing and Testing Brick andStructural Clay TileC 216 Specification for Facing Brick (Solid Masonry UnitsMade from Clay or Shale)C 902 Specification for Pedestrian and Light Traffic PavingBrickE 835/E 835M Guide for Modular Coordination of Clayand Concrete Masonry Units3. Grades3.1 Grades classify bric
10、k according to their resistance todamage by freezing when wet, as defined in Note 1. Threegrades are covered and the grade requirements are shown inTable 1.3.1.1 Grade SW (Severe Weathering)Brick intended foruse where high and uniform resistance to damage caused bycyclic freezing is desired and wher
11、e the brick may be frozenwhen saturated with water.3.1.2 Grade MW (Moderate Weathering)Brick intendedfor use where moderate resistance to cyclic freezing damage ispermissible or where the brick may be damp but not saturatedwith water when freezing occurs.3.1.3 Grade NW (Negligible Weathering)Brick w
12、ith littleresistance to cyclic freezing damage but which are acceptablefor applications protected from water absorption and freezing.NOTE 1The word “saturated,” with respect to this standard, refers tothe condition of a brick that has absorbed water to an amount equal to thatresulting from submersio
13、n in room temperature water for 24 h.1This specification is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.02 on Brick and Structural Clay Tile.Current edition approved Nov. 1, 2008. Published November 2008. Originallyapp
14、roved in 1927. Last previous edition approved in 2005 as C 62 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM webs
15、ite.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Physical Properties4.1 AppearanceIf brick are required to have a particularcolor, texture, finish, uniformity, o
16、r limits on cracks, warpageor other imperfections detracting from the appearance they arepurchased under Specification C 216.4.2 DurabilityWhen Grade is not specified, the require-ments for Grade SW shall govern.4.2.1 Physical Property RequirementsThe brick shallconform to the physical requirements
17、for the Grade specified asprescribed in Table 1. For the compressive strength require-ments in Table 1, test the unit with the compressive forceperpendicular to the bed surface of the unit, with the unit in thestretcher position.4.2.2 Absorption AlternateThe saturation coefficient re-quirement does
18、not apply, provided the 24-h cold waterabsorption of each unit of a random sample of five brick doesnot exceed 8.0 %.4.2.3 Freezing and Thawing AlternativeThe requirementsfor 5 h boiling water absorption and saturation coefficient donot apply, provided a sample of five brick, meeting the strengthreq
19、uirements of Table 1, passes the freezing and thawing test asdescribed in the Rating Section of the Freezing and Thawingtest procedures of Test Methods C67.4.2.3.1 Grade SW: Breakage and Weight LossRequirementNo individual unit separates or disintegratesresulting in a weight loss greater than 0.5 %
20、of its original dryweight.NOTE 2The 50 cycle freezing and thawing test is used as analternative only when the brick do not conform to either Table 1requirements for maximum water absorption and saturation coefficient, orto the requirements of the Absorption Alternate in 4.2.2.4.2.3.2 Grade SW: Crack
21、ing RequirementNo individualunit develops a crack that exceeds, in length, the units leastdimension.4.2.4 Low Weathering Index AlternativeIf the brick areintended for use exposed to weather where the weatheringindex is less than 50 (see Fig. 1), and unless otherwisespecified, the requirements given
22、in Table 1 for 5 h boilingwater absorption and for saturation coefficient shall not applybut the minimum average compressive strength requirement of2500 psi (17.2 MPa) shall apply.TABLE 1 Physical RequirementsDesignationMinimum Compressive Strengthgross area, psi (MPa)Maximum Water Absorptionby 5-h
23、Boiling, %Maximum SaturationCoefficientAAverage of5 BrickIndividualAverage of5 BrickIndividualAverage of5 BrickIndividualGrade SW 3000 (20.7) 2500 (17.2) 17.0 20.0 0.78 0.80Grade MW 2500 (17.2) 2200 (15.2) 22.0 25.0 0.88 0.90Grade NW 1500 (10.3) 1250 (8.6) no limit no limit no limit no limitAThe sat
24、uration coefficient is the ratio of absorption by 24-h submersion in cold water to that after 5-h submersion in boiling water.FIG. 1 Weathering Indices in the United StatesC62082NOTE 3Weathering Index: The effect of weathering on brick is relatedto the weathering index, which for any locality is the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC622008STANDARDSPECIFICATIONFORBUILDINGBRICKSOLIDMASONRYUNITSMADEFROMCLAYORSHALEPDF

链接地址:http://www.mydoc123.com/p-507800.html