ASTM C596-2009e1 Standard Test Method for Drying Shrinkage of Mortar Containing Hydraulic Cement《含水硬性水泥的灰浆干燥收缩用标准试验方法》.pdf
《ASTM C596-2009e1 Standard Test Method for Drying Shrinkage of Mortar Containing Hydraulic Cement《含水硬性水泥的灰浆干燥收缩用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C596-2009e1 Standard Test Method for Drying Shrinkage of Mortar Containing Hydraulic Cement《含水硬性水泥的灰浆干燥收缩用标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C596 091Standard Test Method forDrying Shrinkage of Mortar Containing Hydraulic Cement1This standard is issued under the fixed designation C596; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTECorrected research report footnote in Section 4 editorially in June 2015.1. Scope*1.1 This test method determines the change in length ond
3、rying of mortar bars containing hydraulic cement and gradedstandard sand.1.2 The values stated in SI units are to be regarded asstandard. When combined standards are referenced, the selec-tion of measurement system is at the users discretion subjectto the requirements of the referenced standard.1.3
4、This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. WarningFreshhydrau
5、lic cementitious mixtures are caustic and may causechemical burns to skin and tissue upon prolonged exposure).22. Referenced Documents2.1 ASTM Standards:3C157/C157M Test Method for Length Change of HardenedHydraulic-Cement Mortar and ConcreteC219 Terminology Relating to Hydraulic CementC305 Practice
6、 for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC490/C490M Practice for Use of Apparatus for the Deter-mination of Length Change of Hardened Cement Paste,Mortar, and ConcreteC511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Us
7、ed in theTesting of Hydraulic Cements and ConcretesC778 Specification for SandC1005 Specification for Reference Masses and Devices forDetermining Mass and Volume for Use in the PhysicalTesting of Hydraulic CementsC1437 Test Method for Flow of Hydraulic Cement MortarE177 Practice for Use of the Terms
8、 Precision and Bias inASTM Test Methods3. Terminology3.1 The term “drying shrinkage” is defined as the decreasein length of the test specimen, where the decrease is caused byany factor other than externally applied forces under statedconditions of temperature, relative humidity and evaporationrate i
9、n the environment; the term includes the net effect of avariety of phenomena tending to bring about both increases anddecreases in length during the period in which the testspecimens under consideration are stored in the environmentand in which a number of processes, including hydration of thecement
10、, are taking place at a variety of rates.3.2 Other terms used in this test method are defined inTerminology C219.4. Significance and Use4.1 This test method establishes a selected set of conditionsof temperature, relative humidity and rate of evaporation of theenvironment to which a mortar specimen
11、of stated compositionshall be subjected for a specified period of time during whichits change in length is determined and designated “dryingshrinkage”.4.2 The drying shrinkage of mortar as determined by thistest method has a linear relation to the drying shrinkage ofconcrete made with the same cemen
12、t and exposed to the same1This test method is under the jurisdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.31 on Volume Change.Current edition approved Dec. 1, 2009. Published January 2010. Originallyapproved in 1967. Last previous edition approved in 20
13、07 as C596 07. DOI:10.1520/C0596-091.2Section on Safety, Manual of Cement Testing, Annual Book of Standards,Vol04.01.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to
14、 the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1drying conditions.4Hence this test method may be used whenit is d
15、esired to develop data on the effect of a hydraulic cementon the drying shrinkage of concrete made with that cement.5. Apparatus5.1 Weighing Devices and WeightsWeighing devices andweights used in determining the mass of materials for mortarmixtures shall conform to the requirements of SpecificationC
16、1005.5.2 Glass GraduatesGlass graduates of suitable capacitiesshall conform to the requirements of Specification C1005.5.3 MoldsMolds shall conform to the requirements ofPractice C490/C490M for mortars.5.4 TrowelThe trowel shall have a straight-edged steelblade 100 to 150 mm in length.5.5 TamperThe
17、tamper shall conform to the requirementsof Test Method C157/C157M.5.6 Demolding ApparatusThe demolding apparatus shallconform to the requirements of Test Method C157/C157M.5.7 Length ComparatorThe length comparator shall con-form to the requirements of Practice C490/C490M.6. Temperature and Humidity
18、6.1 LaboratoryThe temperature of the laboratory, drymaterials, and mixing water, and the relative humidity of theair in the laboratory shall conform to the requirements ofSpecification C511.6.2 Moist Storage FacilityThe temperature and humidityof the air in the moist storage facility shall conform t
19、o therequirements of Specification C511.6.3 Drying Room and ControlsThe drying room andcontrols shall conform to the requirements of Test MethodC157/C157M.7. Graded Standard Sand7.1 The graded standard sand shall conform to SpecificationC778.8. Number of Test Specimens8.1 Make at least four test spe
20、cimens (Note 1).NOTE 1Although the number of test specimens may consist of fourspecimens from a single batch of mortar, it is preferable that twelvespecimens be made with four specimens being made from each of threebatches, with each batch being made on a different day.9. Preparation of Molds9.1 Pre
21、pare the specimen molds as required by PracticeC490/C490M.10. Preparation of Test Specimens10.1 Mortar ProportionsAbatch of mortar shall consist of750 g of cement, 1500 g of graded standard sand, and anamount of mixing water sufficient to produce a flow of 110 65 %. The flow shall be determined in c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC5962009E1STANDARDTESTMETHODFORDRYINGSHRINKAGEOFMORTARCONTAININGHYDRAULICCEMENT 含水 硬性 水泥 灰浆 干燥 收缩

链接地址:http://www.mydoc123.com/p-507720.html