1、Designation: C560 88 (Reapproved 2010)1An American National StandardStandard Test Methods forChemical Analysis of Graphite1This standard is issued under the fixed designation C560; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUpdated 57.1 editorially in May 2010.1. Scope1.1 These test methods cover the chemical analysis ofgraphite.1.2 The
3、analytical procedures appear in the following order:SectionsSilicon by the Molybdenum Blue (Colorimetric) Test Method 8 to 14Ironbytheo-Phenanthroline (Colorimetric) Test Method 15 to 21Calcium by the Permanganate (Colorimetric) Test Method 22 to 28Aluminum by the 2-Quinizarin Sulfonic Acid Test Met
4、hod 29 to 35Titanium by the Peroxide (Colorimetric) Test Method 36 to 43Vanadium by the 3,38-Dimethylnaphthidine (Colorimetric) TestMethod 44 to 51Boron by the Curcumin-Oxalic Acid (Colorimetric) Test Method 52 to 591.3 The preferred concentration of sought element in thefinal solution, the limits o
5、f sensitivity, and the precision of theresults are given in Table 1.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
6、 is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See 56.1 forspecific caution statement.2. Referenced Documents2.1 ASTM Standards:2C561 Test Method for Ash in a Graphite S
7、ampleD1193 Specification for Reagent WaterE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with Specifications3. Significance and Use3.1 These test methods provide a practical way to measurethe concentration of certain trace elements in graphite. Manyend uses of graphit
8、e require that it be free of elements whichmay be incompatible with certain nuclear applications. Otherelemental contamination can affect the rate of oxidative deg-radation.3.2 These test methods allow measurement of trace amountsof contaminants with a minimal amount of costly equipment.The colorime
9、tric procedures used are accessible to mostlaboratories.4. Reagents4.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemica
10、l Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.1These test methods are under the jurisdiction of ASTM Committee D02 onPetr
11、oleum Products and Lubricants and are the direct responsibility of Subcommit-tee D02.F0 on Petroleum Products and LubricantsCurrent edition approved May 1, 2010. Published May 2010. Originallyapproved in 1965. Last previous edition approved in 2005 as C560 88 (2005)e1.DOI: 10.1520/C0560-88R10E01.2Fo
12、r referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications, Am
13、ericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc. (
14、USPC), Rockville,MD.TABLE 1 Concentration of Elements, Limits of Sensitivity, andReproducibilityElementConcentrationRange, g/mLSolutionSensitivity Limit,g/mL SolutionReproducibility,Relative, %(s/x 3 100)Silicon 10 to 100 g/100 mL 1 g/100 mL 64Iron 100 to 600 g/100 mL 40 g/100 mL 65Calcium 600 to 30
15、00 g/100 mL 50 g/100 mL 65Aluminum 10 to 100 g/100 mL 2 g/100 mL 60.1Titanium 600 to 3000 g/100 mL 200 g/100 mL 62Vanadium 10 to 130 g/50 mL 5 g/50 mL 65Boron 0.5 to 1.4 g/50 mL 0.1 g/50 mL 6201Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United
16、 States.4.2 When available, National Institute of Standards andTechnology (NIST) certified reagents should be used as stan-dards in preparing calibration curves.4.3 Unless otherwise indicated, references to water shall beunderstood to mean reagent water conforming to SpecificationD1193.4.4 National
17、Institute of Standards and Technology certifiedreagents specified in certain steps of this procedure may nolonger be available. If NIST reagents are not available, then thehighest purity reagent grade shall be substituted.5. Sampling5.1 The entire sample of graphite should be crushed andground to pa
18、ss a No. 60 (250-m) sieve in a roll crusher. Thesample may have been reduced in size initially by drilling thetest bar with silicon carbide-tipped drills.6. Rounding Calculated Values6.1 Calculated values shall be rounded to the desired num-ber of places in accordance with Practice E29.7. Precision
19、and Bias7.1 No statement is being made about either the precision orbias of these test methods. At this time Committee C05 isinvestigating new standard methods of chemical analysis ofgraphite that will eventually replace these test methods. Forthis reason, no statistical study of these test methods
20、has beenplanned.7.2 The relative reproducibility data in Table 1 has nosupportive research report on file and does not conform toASTM precision and bias standards.SILICON BY THE MOLYBDENUM BLUE TESTMETHOD8. Summary of Test Method8.1 Silicomolybdic acid is formed by adding ammoniummolybdate to solubl
21、e silicates in acid solution. The heteropolyacid is reduced with stannous chloride to form a deep bluecolloidal solution. Photometric measurement is made at 765nm. Regular classical gravimetric methods for silica usingsodium carbonate fusion followed by hydrofluoric acid vola-tilization may be suita
22、ble for use.9. Stability of Color9.1 The blue colored solution should be disposed of and thedetermination repeated if a period of 12 h has elapsed betweencolor development and measurements.10. Interferences10.1 There is no interference from the ions usually presentin graphite.11. Reagents11.1 Ammoni
23、um Molybdate (50 g/L)Dissolve 50 g ofammonium molybdate (NH4)6-Mo7O244H2O) in water anddilute to 1 L.11.2 Hydrochloric Acid (HCl) (1+1)Mix equal volumesof concentrated HCl, sp gr 1.19 and water.11.3 Silicon, Standard Solution (1 mL = 1 mg Si)Dissolve10.1 g of sodium silicate (Na2SiO39H2O) in water a
24、nd diluteto 1 L in a volumetric flask. Store in a polyethylene bottle.Determine exact concentration by the standard gravimetricprocedure.11.4 Silicon, Working Solution (1 mL = 0.01 mg Si)Dilute10 mL of standard silicon solution (1 mL = mg Si) to 1 L in avolumetric flask. Transfer to a polyethylene b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC56019882010E1STANDARDTESTMETHODSFORCHEMICALANALYSISOFGRAPHITE 石墨 化学分析 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-467029.html