ASTM C550-2003(2009) Standard Test Method for Measuring Trueness and Squareness of Rigid Block and Board Thermal Insulation.pdf
《ASTM C550-2003(2009) Standard Test Method for Measuring Trueness and Squareness of Rigid Block and Board Thermal Insulation.pdf》由会员分享,可在线阅读,更多相关《ASTM C550-2003(2009) Standard Test Method for Measuring Trueness and Squareness of Rigid Block and Board Thermal Insulation.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C550 03 (Reapproved 2009)Standard Test Method forMeasuring Trueness and Squareness of Rigid Block andBoard Thermal Insulation1This standard is issued under the fixed designation C550; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test m
3、ethod covers locations for measuring thetrueness and squareness of rigid block/board thermal insula-tion. This test method does not purport to address the variabil-ity in board thickness. Thickness is addressed in other ASTMstandards.1.2 The values stated in inch-pound units are to be regardedas sta
4、ndard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this s
5、tandard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC390 Practice for Sampling and Acceptance of ThermalInsulation Lots3. Termin
6、ology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology C168.3.2 Definitions of Terms Specific to This Standard:3.2.1 squarenessthe lack of deviation from a right angle.3.2.2 truenessthe lack of deviation from straightness orflatness.4. Significance and Use4.1 Insu
7、lating blocks or boards that are not true or squaremay not fit properly. Extra labor may be required to obtainproper fit and may affect the product performance as well as theappearance of the finished installation.4.2 This test method provides terminology and describeslocations for obtaining consist
8、ent measurements of truenessand squareness of blocks and boards.5. Apparatus5.1 Straightedge, minimum length equal to the maximumdimension of the block or board with a maximum out oftrueness of 6 0.003 in./ft (60.25 mm/m).5.2 Rigid Ruler, graduated to 0.03 in. (1.0 mm) or finer.5.3 Square, shall hav
9、e sides at least as long as the longestside of the block. If the longest side of the block is greater than20 in. (500 mm), then the length of the square must be at least20 in. (500 mm). The maximum deviation from 90 shall be nomore than 63 min (60.9 mrad).5.4 Flat Surface, large enough to accommodat
10、e the block orboard in its full length and width dimensions, with a truenessof 60.008 in./ft (60.65 mm/m).5.5 Feeler Gage Set, from 0.001 to 0.020 in. (0.03 to 0.50mm).5.6 Tape Measure, steel, long enough to measure the longestside of the block, graduated in 0.031 in. (1 mm) intervals.6. Test Specim
11、ens6.1 The test specimens shall be of commercial size.6.2 The number of test specimens shall be defined by theappropriate product specification.6.3 When the appropriate product specification does notcover sampling, samples shall be selected in accordance withPractice C390 inspection requirements.1Th
12、is test method is under the jurisdiction ofASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.32 on MechanicalProperties.Current edition approved Nov. 1, 2009. Published March 2010. Originallyapproved in 1964. Last previous edition approved in 2003 asC550 03
13、. DOI:10.1520/C0550-03R09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100
14、Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Procedure7.1 Edge Trueness in the x/y Direction:7.1.1 With the straightedge next to the block/board on theflat surface, concave deviation from true shall be determined atthe point of maximum deviation (see Fig. 1 A an
15、d B).7.1.2 For convex deviation from true, the deviation shall bemeasured by equalizing the distance between the straightedgeand the block/board at both corners of the block/board (see Fig.1 A and B).7.1.3 Deviation from true shall be determined to the nearest0.03 in. (1.0 mm).7.2 Edge Trueness in t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC55020032009STANDARDTESTMETHODFORMEASURINGTRUENESSANDSQUARENESSOFRIGIDBLOCKANDBOARDTHERMALINSULATIONPDF

链接地址:http://www.mydoc123.com/p-466989.html