《ASTM C511-2013 Standard Specification for Mixing Rooms Moist Cabinets Moist Rooms and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes《水硬水泥和混凝土试验用搅拌室、湿气箱、.pdf》由会员分享,可在线阅读,更多相关《ASTM C511-2013 Standard Specification for Mixing Rooms Moist Cabinets Moist Rooms and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes《水硬水泥和混凝土试验用搅拌室、湿气箱、.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C511 09C511 13Standard Specification forMixing Rooms, Moist Cabinets, Moist Rooms, and WaterStorage Tanks Used in the Testing of Hydraulic Cementsand Concretes1This standard is issued under the fixed designation C511; the number immediately following the designation indicates the year o
2、foriginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification includes requirements for mixing rooms
3、 where paste and mortar specimens are prepared; and for moistcabinets, moist rooms, and water storage tanks where paste, mortar, and concrete specimens are stored.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.Values in S
4、I units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion androunding given in Standard IEEE/ASTM SI 10, of measurements made in other units.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its u
5、se. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C51 Terminology Relating to Lime and Limestone (as used by the Industry)E77 T
6、est Method for Inspection and Verification of ThermometersIEEE/ASTM SI 10 Standard for Use of the International System of Units (SI): The Modern Metric System3. Terminology3.1 Definitions:3.1.1 mixing room, na room with controlled temperature and relative humidity where cement paste and mortar speci
7、mens areprepared.3.1.2 moist cabinet, na compartmented storage facility of moderate dimensions with controlled temperature and relativehumidity.3.1.3 moist room, na “walk-in” storage facility with controlled temperature and relative humidity, commonly called a fogroom when the prescribed relative hu
8、midity is achieved by the atomization of water.4. Requirements for Cement Mixing Rooms4.1 The temperature of the air in the vicinity of the mixing slab, molds, and base plates shall be maintained at 23.0 6 4.0 Cand at a relative humidity of not less than 50 %.4.2 The temperature of the mixing water
9、used to prepare cement paste and mortar specimens shall be 23.0 6 2.0 C.5. Temperature Measuring Devices5.1 Reference Temperature Measuring Deviceused to verify the temperature recorder, must be accurate and readable to 0.5C. A copy of the certificate or report which verifies the accuracy shall be a
10、vailable in the laboratory.1 This specification is under the jurisdiction of ASTM Committee C01 on Cement and is the direct responsibility of Subcommittee C01.95 on Coordination of Standards.Current edition approved June 1, 2009Dec. 1, 2013. Published July 2009January 2014. Originally approved in 19
11、68. Last previous edition approved in 20062009 asC51106.09. DOI: 10.1520/C0511-09.10.1520/C0511-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Docu
12、ment Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM r
13、ecommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box
14、 C700, West Conshohocken, PA 19428-2959. United States1NOTE 1The ice-point method described in Test Method E77 may be used to ensure that no damage to the reference thermometer has occurred duringshipping.5.2 Temperature Recordershall record temperatures every 15 min or less and shall be accurate an
15、d readable to 1 C. The datafrom the recorder shall be evaluated at a minimum of once each week. A record of this evaluation documenting the date checked,a confirmation that the data is within the required temperature range, and the name of the individual performing this evaluationshall be maintained
16、 in the laboratory. (Note 2)NOTE 2This requirement may be satisfied by an initialed and dated temperature recorder chart. Brief changes in the temperature due to door openingsshould be ignored.5.2.1 The temperature recorder shall be verified at least every six months or whenever there is a question
17、of accuracy.5.2.1.1 For moist cabinets and rooms, position the reference temperature measuring device in a readable position in air as nearas practical to the temperature recorder probe. Keep the door closed for at least 5 min prior to taking readings. Record thetemperature readings of both the temp
18、erature recorder and the reference temperature measuring device. When taking thesereadings, the reference temperature measuring device shall remain in the moist cabinet or room and read immediately upon openingthe door.5.2.1.2 For water storage tanks, position the reference temperature measuring dev
19、ice in a readable position in water as near aspractical to the temperature recorder probe. Without removing the reference temperature measuring device from the water, recordthe temperature readings of both the temperature recorder and the reference temperature measuring device after the temperatures
20、have stabilized.5.2.1.3 Verify the accuracy of the temperature recorder by comparing the reading of the temperature recorder with that of thereference temperature measuring device during the normal operation of the moist cabinet, moist room or water storage tanks. Ifthe difference between the temper
21、ature readings is greater than 1 C, the temperature recorder shall be adjusted to within 0.5 Cof the reference temperature measuring device.6. Requirements for Moist Cabinets and Moist Rooms6.1 GeneralExcept during those times when specimens are being placed into or removed from storage, maintain th
22、eatmosphere in a moist cabinet or moist room at a temperature of 23.0 6 2.0 C and a relative humidity of not less than 95 %.Maintain atmospheric conditions within a moist cabinet or moist room such that test specimens in storage are saturated withmoisture to the degree needed to ensure that the expo
23、sed surfaces of all specimens in storage both look moist and feel moist (SeeNote 5). Equip all moist cabinets and moist rooms with a temperature recorder. The use of humidity recording devices is optional.Keep shelves on which fresh specimens are placed level.6.1.1 The air temperature inside the moi
24、st cabinet or moist room shall be controlled with provisions made for heating or cooling,or both, as may be necessary. This shall be accomplished in one of two ways:6.1.1.1 Thermostatically control the air temperature within the moist cabinet or moist room when surrounding space is notconditioned. I
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC5112013STANDARDSPECIFICATIONFORMIXINGROOMSMOISTCABINETSMOISTROOMSANDWATERSTORAGETANKSUSEDINTHETESTINGOFHYDRAULICCEMENTSANDCONCRETES

链接地址:http://www.mydoc123.com/p-466899.html