ASTM C508 C508M-2000(2015) Standard Specification for Asbestos-Cement Underdrain Pipe《石棉水泥地下排水管的标准规格》.pdf
《ASTM C508 C508M-2000(2015) Standard Specification for Asbestos-Cement Underdrain Pipe《石棉水泥地下排水管的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C508 C508M-2000(2015) Standard Specification for Asbestos-Cement Underdrain Pipe《石棉水泥地下排水管的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C508/C508M 00 (Reapproved 2015) American Association StateHighway and Transportation Officials StandardAASHTO No.: M189-81IStandard Specification forAsbestos-Cement Underdrain Pipe1This standard is issued under the fixed designation C508/C508M; the number immediately following the desig
2、nation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers asbes
3、tos-cement perforatedand plain pipe intended for use in the conveyance of drainagewater for the subsurface drainage of highways, airports, farms,foundations, and other similar drainage work.1.2 The text of this standard references notes and footnoteswhich provide explanatory material. These notes an
4、d footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall b
5、e used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-pri
6、ate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C150/C150M Specification for Portland CementC458/C458M Test Method for Organic Fiber Content ofAsbestos-Cement ProductsC500/C500M Test Methods for Asbest
7、os-Cement PipeC595/C595M Specification for Blended Hydraulic CementsC608 Standard Method of Test for Brittle Ring TensileStrength of Chemically Setting Silicate and SilicaChemical-Resistant Mortars (Withdrawn 1983)3C618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in Co
8、ncreteD2946 Terminology for Asbestos and AsbestosCementProducts2.2 Federal Standard:No. 123 Marking for Shipment Civil Agencies42.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage42.4 Other Standards:Uniform Freight Classification Rules5National Motor Freight Classification Rules63. T
9、erminology3.1 Definitions:3.1.1 coupling, ncomponent made from a larger diameterpipe of the same type or class, or of Type II and a higher class,or produced otherwise to yield at least equal performance, forjoining asbestos-cement pipe that when properly installed,forms a silt-tight joint, allows al
10、ignment corrections and slightchanges in direction, and provides an assembled joint equiva-lent in serviceability and strength to the pipe sections.3.1.2 loteach 400 m 1300 ft of pipe or less of a giventype and size manufactured on each machine during a 24-hperiod.3.2 Additional terminology is given
11、 in Terminology D2946.4. Sizes and Types4.1 Asbestos-cement underdrain pipe furnished under thisspecification shall be known as “asbestos-cement underdrainpipe.” It shall be furnished in nominal inside diameters of 10,15, 20, 25, and 30 cm 4, 6, 8, 10, and 12 in. The types of pipe1This specification
12、 is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Products and is the direct responsibility of C17.03 onAsbestos - Cement Sheet Products and Accessories.Current edition approved July 1, 2015. Published July 2015. Originally approvedin 1963. Last previous edition approved in
13、2009 as C508 00(2009)1. DOI:10.1520/C0508_C0508M-00R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The l
14、ast approved version of this historical standard is referenced onwww.astm.org.4Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.5Available from the Uniform Classification Commission, Room 1106, 222 S.Riverside Plaza, Ch
15、icago, IL 60606.6Available from National Motor Freight Inc., 1616 P. St., N.W., Washington, DC20036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1shall be known as Type I and Type II corresponding to thechemical requirements given i
16、n Section 9.NOTE 1To assist the purchaser in choosing the type of pipe mostsuitable for his use, guidelines for the definition of aggressiveness of waterand of soil environments for selection of the proper type of asbestos-cement pipe are covered in the appropriate sections of Test MethodsC500/C500M
17、.5. Materials and Manufacture5.1 Asbestos-cement underdrain pipe shall be composed ofan intimate mixture of portland cement or portland blast-furnace slag cement described in Specification C150/C150M orportland blast-furnace slag or pozzolan cements described inSpecification C595/C595M and asbestos
18、fiber with or withoutfine silica or additives containing such silica meeting Specifi-cation C608 that is capable of reacting completely to yieldcalcium silicate reaction products upon autoclaving; and as-bestos fiber. The mixture shall not contain more than 0.2 % ofnondeleterious organic matter as d
19、etermined by Test MethodC458/C458M. The material shall be of laminar construction,formed under pressure to a homogeneous structure, and curedto meet the physical and chemical requirements of this speci-fication.6. Crushing Strength6.1 Crushing tests shall be conducted before shipment. Pipeof 30 cm 1
20、 ft lengths cut from unmachined portions of thepipe shall have the minimum crushing strength prescribed inTable 1 when tested in accordance with the Procedure sectionof Test Methods C500/C500M, except that when the perforatedunderdrain pipe is tested, the sample shall contain four circum-ferential r
21、ows of holes with the first row 4 cm 1.5 in. from theend. The specimen shall be tested with the line of symmetry ofthe rows facing downward, with the rows of holes being in thelower two quadrants.6.2 In case a specimen fails to meet the crushing testrequirement, refer to 13.3.7. Couplings7.1 Each st
22、andard, short, or random length of pipe shall beprovided with a coupling for the purpose of maintainingalignment and to ensure close joints.8. Fittings8.1 Asbestos-cement underdrain pipe fittings shall be suit-able in size, type, crushing strength, and design for the pipewith which they will be furn
23、ished.9. Chemical Requirements9.1 When tested in accordance with the Procedure section ofTest Methods C500/C500M, the amount of uncombined cal-cium hydroxide shall not exceed 1.0 % for Type II pipe.NOTE 2There are no chemical requirements for Type I Pipe.9.2 If the uncombined calcium hydroxide excee
24、ds 1 %, referto 13.4.10. Sizes and Dimensions10.1 The nominal standard length for asbestos-cement un-derdrain pipe shall be either 3 or 4 m 10 or 13 ft.Amaximumof 15 % of the total footage of any one size and type for anyorder may be furnished, at the manufacturers option, in pipelengths shorter tha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC508C508M20002015STANDARDSPECIFICATIONFORASBESTOSCEMENTUNDERDRAINPIPE 石棉 水泥 地下 排水管 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-466887.html