ASTM C507M-2010b Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe (Metric)《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格(公制)》.pdf
《ASTM C507M-2010b Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe (Metric)《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格(公制)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C507M-2010b Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe (Metric)《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格(公制)》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C507M 10bStandard Specification forReinforced Concrete Elliptical Culvert, Storm Drain, andSewer Pipe (Metric)1This standard is issued under the fixed designation C507M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers
3、 reinforced elliptically shapedconcrete pipe to be used for the conveyance of sewage,industrial wastes, storm water, and for the construction ofculverts.1.2 Pipe designed for placement with the major axis hori-zontal shall be designated as “Horizontal Elliptical Pipe.” Pipedesigned for placement wit
4、h the major axis vertical shall bedesignated as “Vertical Elliptical Pipe.”1.3 This specification is the SI companion to SpecificationC507.NOTE 1This specification is a manufacturing and purchase specifica-tion only, and does not include requirements for bedding, backfill, or therelationship between
5、 field load condition and the strength classification ofpipe. However, experience has shown that the successful performance ofthis product depends upon the proper selection of the class of pipe, typeof bedding and backfill, and care that the installation conforms toconstruction specifications. The o
6、wner of the reinforced concrete pipespecified herein is cautioned that he must correlate the field requirementswith the class of pipe specified and provide inspection at the constructionsite.2. Referenced Documents2.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelA82/A82M Specifi
7、cation for Steel Wire, Plain, for ConcreteReinforcementA185/A185M Specification for Steel Welded Wire Rein-forcement, Plain, for ConcreteA496/A496M Specification for Steel Wire, Deformed, forConcrete ReinforcementA497/A497M Specification for Steel Welded Wire Rein-forcement, Deformed, for ConcreteA6
8、15/A615M Specification for Deformed and PlainCarbon-Steel Bars for Concrete ReinforcementA706/A706M Specification for Low-Alloy Steel Deformedand Plain Bars for Concrete ReinforcementC33 Specification for Concrete AggregatesC150 Specification for Portland CementC260 Specification for Air-Entraining
9、Admixtures for Con-creteC309 Specification for Liquid Membrane-Forming Com-pounds for Curing ConcreteC494/C494M Specification for Chemical Admixtures forConcreteC497M Test Methods for Concrete Pipe, Manhole Sections,or Tile MetricC595 Specification for Blended Hydraulic CementsC618 Specification for
10、 Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC822 Terminology Relating to Concrete Pipe and RelatedProductsC989 Specification for Slag Cement for Use in Concreteand MortarsC1017/C1017M Specification for Chemical Admixtures forUse in Producing Flowing ConcreteC1116 Specificati
11、on for Fiber-Reinforced Concrete andShotcrete3. Terminology3.1 DefinitionsFor definitions of terms relating to con-crete pipe, see Terminology C822.4. Classification4.1 Pipe manufactured according to this specification shallbe of five classes each for horizontal elliptical and verticalelliptical pip
12、e with identification as follows:Horizontal Elliptical Pipe Vertical Elliptical PipeClass HE-A Class VE-IIClass HE-I Class VE-IIIClass HE-II Class VE-IVClass HE-III Class VE-VClass HE-IV Class VE-VI1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct
13、responsibility of Subcommittee C13.02 onReinforced Sewer and Culvert Pipe.Current edition approved Oct. 1, 2010. Published October 2010. Originallyapproved in 1980. Last previous edition approved in 2010 as C507M 10A1. DOI:10.1520/C0507M-10B.2For referenced ASTM standards, visit the ASTM website, ww
14、w.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2
15、The strength requirements for horizontal elliptical pipeare prescribed in Table 1 and for vertical elliptical pipe areprescribed in Table 2.5. Basis of Acceptance5.1 Unless otherwise designated by the owner at the time of,or before, placing an order, there are two separate andalternative bases of ac
16、ceptance. Independent of the method ofacceptance, the pipe shall be designed to meet both the 0.01-in.crack and ultimate strength requirements specified in Table 1.5.1.1 Acceptance on Basis of Plant Load-Bearing Tests,Material Tests, and Inspection of Manufactured Pipe for VisualDefects and Imperfec
17、tionsAcceptability of the pipe in alldiameters and classes produced in accordance with 7.1 or 7.2shall be determined by the results of the three-edge-bearingtests as defined in 11.3.1; by such material tests as are requiredin 6.2, 6.3, 6.5 and 6.6; by an absorption test of the concretefrom the wall
18、of the pipe as required in 11.9; and by visualinspection of the finished pipe to determine its conformancewith the accepted design prescribed and its freedom fromdefects.5.1.2 Acceptance on the Basis of Material Test and Inspec-tion of Manufactured Pipe for Defects and ImperfectionsAcceptability of
19、the pipe in all diameters and classes producedin accordance with 7.1 or 7.2 shall be determined by the resultsof such material tests as are required in 6.2, 6.3, 6.5 and 6.6;bycrushing tests on concrete cores or cured concrete cylinders; byan absorption test of the concrete from the wall of the pipe
20、 foreach mix design that is used on an order; and by inspection ofthe finished pipe, including amount and placement of rein-forcement, to determine its conformance with the accepteddesign and its freedom from defects.5.1.3 When agreed upon by the owner and the manufacturer,any portion or any combina
21、tion of the tests itemized in 5.1.1 or5.1.2 may form the basis of acceptance.TABLE 1 Design Requirements for Horizontal Elliptical (HE) PipeANOTE 1The test load in kilonewtons per linear metre equals D-load 3 inside span in millimetres.NOTE 2Single cage reinforcement, providing tension steel at the
22、top, bottom, and springline, shall be permitted instead of double cage reinforcement.The area of such reinforcement shall be 112 % of the tabulated inner cage area.NOTE 3An inner and outer cage plus quadrant mats shall be permitted instead of double cage reinforcement. The area of such reinforcement
23、 shallbe in accordance with Fig. 1.NOTE 4An inner and outer cage plus a middle cage shall be permitted instead of double cage reinforcement. The area of such reinforcement shallbe in accordance with Fig. 2.Designated Di-ameter, Equiva-lent RoundSize, mmDesignatedRise, mm 3Span, mmMinimumWallThick-ne
24、ss,mmReinforcement, cm2/linear mClassHE-AClassHE-IClassHE-IIClassHE-IIIClassHE-IVD-Loads0.3=30Ult = 450.3=40Ult = 600.3=50Ult = 750.3=65Ult = 1000.3 = 100Ult = 150InCageOutCageInCageOutCageInCageOutCageInCageOutCageInCageOutCage450 365 3 575 69 1.7 . . . 2.3 . . . 3.0 . . . 4.0 . . . 5.7 . . .600 49
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC507M2010BSTANDARDSPECIFICATIONFORREINFORCEDCONCRETEELLIPTICALCULVERTSTORMDRAINANDSEWERPIPEMETRIC

链接地址:http://www.mydoc123.com/p-466875.html