1、Designation: C 494/C 494M 08Standard Specification forChemical Admixtures for Concrete1This standard is issued under the fixed designation C 494/C 494M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specification covers materials for use as chemic
3、aladmixtures to be added to hydraulic-cement concrete mixturesin the field for the purpose or purposes indicated for the seventypes as follows:1.1.1 Type AWater-reducing admixtures,1.1.2 Type BRetarding admixtures,1.1.3 Type CAccelerating admixtures,1.1.4 Type DWater-reducing and retarding admixture
4、s,1.1.5 Type EWater-reducing and accelerating admixtures,1.1.6 Type FWater-reducing, high range admixtures, and1.1.7 Type GWater-reducing, high range, and retardingadmixtures.1.2 This specification stipulates tests of an admixture withsuitable concreting materials as described in 11.1-11.3 or withce
5、ment, pozzolan, aggregates, and an air-entraining admixtureproposed for specific work (11.4). Unless specified otherwiseby the purchaser, the tests shall be made using concretingmaterials as described in 11.1-11.3.NOTE 1It is recommended that, whenever practicable, tests be madeusing the cement, poz
6、zolan, aggregates, air-entraining admixture, and themixture proportions, batching sequence, and other physical conditionsproposed for the specific work (11.4) because the specific effects producedby chemical admixtures may vary with the properties and proportions ofthe other ingredients of the concr
7、ete. For instance, Types F and Gadmixtures may exhibit much higher water reduction in concrete mixtureshaving higher cement factors than that listed in 12.1.1.Mixtures having a high range water reduction generally display a higherrate of slump loss. When high-range admixtures are used to impartincre
8、ased workability (6 to 8-in. slump 150 to 200mm), the effect maybe of limited duration, reverting to the original slump in 30 to 60 mindepending on factors normally affecting rate of slump loss. The use ofchemical admixtures to produce high-slump (flowing) concrete is coveredby Specification C 1017.
9、NOTE 2The purchaser should ensure that the admixture supplied foruse in the work is equivalent in composition to the admixture subjected totest under this specification (see Section 6, Uniformity and Equivalence).NOTE 3Admixtures that contain relatively large amounts of chloridemay accelerate corros
10、ion of prestressing steel. Compliance with therequirements of this specification does not constitute assurance of accept-ability of the admixture for use in prestressed concrete.1.3 This specification provides for three levels of testing.1.3.1 Level 1During the initial approval stage, proof ofcompli
11、ance with the performance requirements defined inTable 1 demonstrates that the admixture meets the require-ments of this specification.Admixtures (except for Types B, C,and E) shall qualify for provisional compliance when thephysical requirements and any of the alternative compressivestrength requir
12、ements in Table 1 are met. If subsequent testresults at 6 months or one year fail to meet the standardrequirement of 100 % of reference strength, the compliance ofthe admixture to this standard is withdrawn and all users of theadmixture shall be notified immediately. Uniformity andequivalence tests
13、of Section 6 shall be carried out to provideresults against which later comparisons can be made (See Note4).NOTE 4Allowing for provisional compliance while retaining longerterm compressive strength requirements promotes more rapid qualificationof new materials, but also provides assurance that new a
14、dmixturetechnologies will not exhibit unexpected longer term performance. Thealternative compressive strength requirements in Table 1 are based onstatistical analysis of 103 Specification C 494/C 494M evaluation tests.The alternative requirements correspond to a 99 % probability of passingsubsequent
15、 test age requirements.21.3.2 Level 2Limited retesting is described in 5.2, 5.2.1and 5.2.2. Proof of compliance with the requirements of Table1 demonstrates continued conformity of the admixture with therequirements of the specification.1.3.3 Level 3For acceptance of a lot or for measuringuniformity
16、 within or between lots, when specified by thepurchaser, the uniformity and equivalence tests of Section 6shall be used.1.4 The values stated in either inch-pound or SI units shallbe regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system
17、must be used independently of the other, without combiningvalues in any way.1.5 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes1This specification is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates
18、and is the direct responsibility of SubcommitteeC09.23 on Chemical Admixtures.Current edition approved Jan. 1, 2008. Published January 2008. Originallyapproved in 1962. Last previous edition approved in 2005 as C 494/C 494M 05a.2Supporting data have been filed at ASTM International Headquarters and
19、maybe obtained by requesting Research Report RR: C09-1030.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Copyright by ASTM Intl (all rights reserved); Fri Aug 15 03:5
20、5:59 EDT 2008Downloaded/printed byGuo Dehua (CNIS) pursuant to License Agreement. No further reproductions authorized.(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.6 The following precautionary caveat pertains only to thetest method sections, Sectio
21、ns 11-18 of this Specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions pri
22、or to use.2. Referenced Documents2.1 ASTM Standards:3C33 Specification for Concrete AggregatesC 39/C 39M Test Method for Compressive Strength of Cy-lindrical Concrete SpecimensC78 Test Method for Flexural Strength of Concrete (UsingSimple Beam with Third-Point Loading)C 136 Test Method for Sieve Ana
23、lysis of Fine and CoarseAggregatesC 138/C 138M Test Method for Density (Unit Weight),Yield, and Air Content (Gravimetric) of ConcreteC 143/C 143M Test Method for Slump of Hydraulic-Cement ConcreteC 150 Specification for Portland CementC 157/C 157M Test Method for Length Change of Hard-ened Hydraulic
24、-Cement Mortar and ConcreteC 183 Practice for Sampling and the Amount of Testing ofHydraulic CementC 192/C 192M Practice for Making and Curing ConcreteTest Specimens in the LaboratoryC 231 Test Method for Air Content of Freshly MixedConcrete by the Pressure MethodC 260 Specification forAir-Entrainin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC494C494M2008STANDARDSPECIFICATIONFORCHEMICALADMIXTURESFORCONCRETEPDF

链接地址:http://www.mydoc123.com/p-466756.html