《ASTM C490-2007 Standard Practice for Use of Apparatus for the Determination of Length Change of Hardened Cement Paste Mortar and Concrete《硬化水泥浆、灰浆和混凝土长度变化测定用仪器使用的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C490-2007 Standard Practice for Use of Apparatus for the Determination of Length Change of Hardened Cement Paste Mortar and Concrete《硬化水泥浆、灰浆和混凝土长度变化测定用仪器使用的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 490 07Standard Practice forUse of Apparatus for the Determination of Length Change ofHardened Cement Paste, Mortar, and Concrete1This standard is issued under the fixed designation C 490; the number immediately following the designation indicates the year oforiginal adoption or, in th
2、e case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers the requirements for the apparatusand equipment used to prepare
3、 specimens for the determinationof length change in hardened cement paste, mortar, andconcrete, the apparatus and equipment used for the determina-tion of these length changes, and the procedures for its use.1.2 Methods for the preparation and curing of test speci-mens, conditions of testing and cur
4、ing, and detailed proceduresfor calculating and reporting test results are contained inapplicable test methods.1.3 The values stated in SI units or inch-pound units are tobe regarded as standard. The values in each system may not beexact equivalents; therefore, each system shall be used inde-pendent
5、ly of the other. Combining values from the two systemsmay result in nonconformance with the standard.2. Referenced Documents2.1 ASTM Standards:2C511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and ConcretesC 1005 Specifi
6、cation for Reference Masses and Devices forDetermining Mass and Volume for Use in the PhysicalTesting of Hydraulic Cements3. Terminology3.1 length changean increase or decrease in the lineardimension of a test specimen, measured along the longitudinalaxis, due to causes other than applied load.4. Si
7、gnificance and Use4.1 This practice is intended to provide standard require-ments for apparatus common to many test methods used inconnection with cement and concrete and standardized proce-dures for its use. The detailed requirements as to materials,mixtures, specimens, conditioning of specimens, n
8、umber ofspecimens, ages at which measurements are to be made,interpretation of results, and precision and bias are left to bedealt with in specific test methods.5. Apparatus5.1 Reference Masses and Devices for Determining Massand Volume, shall conform to the requirements of SpecificationC 1005.5.2 M
9、olds, shall have either one or two compartments andshall be constructed as shown in Fig. 1 or Fig. 2. Molds for testspecimens used in determining the length change of cementpastes and mortars shall provide for 25 by 25 by 285-mmprisms having a 250-mm gauge length, or for 1 by 1 by 1114in. prisms hav
10、ing a 10in. gauge length. Molds for testspecimens used in the length change of concretes shall providefor prisms of the desired cross section having a 10-in. or250-mm gauge length. In some routine tests, 25 by 25 by160-mm specimens with a gauge length of 125 mm, or 1 by 1by 614 in. specimens with a
11、gauge length of 5-in. arepermitted, but in case of dispute, results obtained with speci-mens of 250-mm 10-in. gauge length shall govern.5.2.1 The gauge length shall be considered as the nominallength between the innermost ends of the gauge studs. Theparts of the molds shall be tight fitting and firm
12、ly held togetherwhen assembled, and their surfaces shall be smooth and free ofpits. The molds shall be made of steel or other hard metal notreadily attacked by the cement paste, mortar, or concrete. Thesides of the molds shall be sufficiently rigid to preventspreading or warping. For the molds shown
13、 in Fig. 1, thetolerance on dimension A is 60.7 mm. For the molds shown inFig. 2, the tolerance on dimension A is 60.03 in.5.2.2 Each end plate of the mold shall be equipped to holdproperly in place, during the setting period, one of the gaugestuds shown in Fig. 1 or Fig. 2. The gauge studs shall be
14、 ofAmerican Iron and Steel Institute (AISI)3Type 316 stainlesssteel or other corrosion-resistant metal of similar hardness.Gauge studs of Invar or similar metal shall be used whenspecimens are tested at widely different temperatures. To1This practice is under the jurisdiction ofASTM Committee C01 on
15、 Cement andis the direct responsibility of Subcommittee C01.95 on Coordination of Standards.Current edition approved June 1, 2007. Published July 2007. Originally approvedin 1962. Last previous edition approved in 2004 as C 490 04.2For referenced ASTM standards, visit the ASTM website, www.astm.org,
16、 orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Details on this material are available from American Iron and Steel Institute(AISI), 1140 Connecticut Ave., NW, Suite 705, Washin
17、gton, DC 20036, http:/www.steel.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.prevent restraint of the gauge studs before demolding of thespecimen, the device fo
18、r holding the gauge studs in positionshall be so arranged that, if necessary, it can be partially orcompletely released after the compaction of the paste or mortarinto place in the mold. The gauge studs shall be set so that theirprincipal axes coincide with the principal axis of the testspecimen. Fo
19、r the molds shown in Fig. 1, gauge studs shallextend into the specimen 17.5 6 0.5 mm and the distancebetween the inner ends of the gauge studs shall be 250.0 6 2.5mm and 250 mm shall be considered the gauge length forcalculating length change. For the molds shown in Fig. 2,gauge studs shall extend i
20、nto the specimen 0.625 6 0.025 in.and the distance between the inner ends of the gauge studs shallbe 10.00 6 0.10 in. and 10 in. shall be considered the gaugelength for calculating length change.5.3 Length Comparator, for determining length change ofspecimens, shall be designed to accommodate the si
21、ze ofspecimen employed and to provide or permit a positive meansof contact with the gauge studs and the convenient and rapidobtaining of comparator readings (Note 1).5.3.1 The comparator for determining length changes ofspecimens produced in the molds shown in Fig. 1 shall providea dial micrometer o
22、r other measuring device graduated to readin 0.002-mm units or less, accurate within 0.002 mm in any0.020-mm range, and within 0.004 mm in any 0.200-mmrange, and sufficient range (at least 8.0 mm) in the measuringdevice to allow for small variations in the actual length ofvarious specimens. The term
23、inals of the comparator shall beplane, polished and heat-treated. They shall be fitted withcollars held in place with set screws. The collars shall extend1.5 6 0.1 mm beyond the plane face of the terminal and havean inside diameter 0.5 mm greater than the average diameter ofthe gauge studs that must
24、 fit into the collars.NOTE 1One type of instrument that has been found satisfactory foruse with small prisms is shown in Fig. 3. A horizontal comparator shouldbe used with prisms with a cross section greater than 9 in.2or 58 cm2.5.3.2 The comparator for determining length changes ofspecimens produce
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC4902007STANDARDPRACTICEFORUSEOFAPPARATUSFORTHEDETERMINATIONOFLENGTHCHANGEOFHARDENEDCEMENTPASTEMORTARANDCONCRETE

链接地址:http://www.mydoc123.com/p-466749.html