ASTM C450-2002 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping and Vessel Lagging《公称尺寸的管件、容器隔热层用绝热配件覆盖物生产的标准实施规范》.pdf
《ASTM C450-2002 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping and Vessel Lagging《公称尺寸的管件、容器隔热层用绝热配件覆盖物生产的标准实施规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C450-2002 Standard Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping and Vessel Lagging《公称尺寸的管件、容器隔热层用绝热配件覆盖物生产的标准实施规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 450 02Standard Practice forFabrication of Thermal Insulating Fitting Covers for NPSPiping, and Vessel Lagging1This standard is issued under the fixed designation C 450; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides tables of dimensions of pre-formed insulation that may be used in fabricating cov
3、ers foruse on valves, ells, tees, flanges, and vessels in the pressurerange from 150 to 1500 psi (1 to 10 MPa). These tables, whichare part of this standard, are published separately as the ASTMRecommended Dimensional Standards for Fabrication of Ther-mal Insulation Fitting Covers for NPS Piping, an
4、d VesselLagging. The tables provide dimensions for use in formingpipe fitting covers for NPS pipe operating at high temperatureand low temperature. The tables also include dimensions foruse in forming thermal insulation into curved segments, andlagging, for application on vessels. This practice does
5、 not applyto reflective-type insulation.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory
6、limitations prior to use.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information purposes only.2. Referenced Documents2.1 ASTM Standards:C 585 Practice for Inner and Outer Diameters of RigidThermal Insulation for Nomina
7、l Sizes of Pipe and Tubing(NPS System)22.2 ASTM Adjuncts:ADJC0450 Recommended Dimensional Standards for Fab-rication of Thermal Insulating Fitting Covers for NPSPiping and Vessel Lagging33. Significance and Use3.1 This system of dimensions provides a guide for formingthermal insulation in advance of
8、 field application. Formingmay be done by cutting, grinding, milling, or molding, depend-ing upon the method most suitable for the thermal insulationbeing fabricated. It is equally applicable for all temperatureranges.4. Apparatus4.1 Thermal insulation can be formed into shapes by nu-merous methods.
9、 In general, insulations may be cut by circularor band saws, shaped by grinders or millers, or molded. Eachmethod has certain advantages and disadvantages, dependingupon the material to be formed, number of cuts required,material waste permissible, and quantity of fittings beingproduced. Adhesives a
10、nd fabrication cements can be appliedfrom dip pots, rollers, doctor blades, brush, or trowel, depend-ing upon the materials being used. For these reasons, althoughstandardized equipment may be devised for certain formingfunctions, no completely standardized equipment recommen-dation can be suggested
11、.5. Basis of Design5.1 All dimensions presented are based on the use of pipeinsulation manufactured to Practice C 585 and to the BasicDimensional Standards for Pipe Insulation as given in Tables 1and Tables 2 of the ASTM Recommended Dimensional Stan-dards for Prefabrication and Field Fabrication of
12、ThermalInsulation Fitting Covers for NPS Piping, and Vessel Lagging.35.2 The tables provide dimensions for insulation fittingcovers for installation on nominal pipe size (NPS) pipeoperating at high and low temperatures.5.3 Dimensions presented for cutting beveled blocks frompreformed thermal insulat
13、ion (lags) are based on blocks 6 in.(152 mm) wide by the thickness required.5.4 Dimensions given for flanged pairs, flanged fittings, andflanged valves do not allow for flange bolt removal. When boltremoval is required, the covering length over the flange shallbe increased as specified by the purcha
14、ser.6. Fabrication6.1 The main body of the insulation fitting may be cut fromstandard pipe size pipe covering of the proper size and samethickness tolerance as the pipe insulation.6.2 Where two insulations of different temperature ratings1This practice is under the jurisdiction of ASTM Committee C16
15、 on ThermalInsulation and is the direct responsibility of Subcommittee C16.20 on HomogeneousInorganic Thermal Insulations.Current edition approved July 10, 2002. Published November 2002. Originallypublished as C 450 60 T. Last previous edition C 450 99e1.2Annual Book of ASTM Standards, Vol 04.06.3Av
16、ailable at a nominal cost from ASTM Headquarters. Order Adjunct:ADJC0450.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.are required, each should be placed in its proper location in thefitting in double layer construction.6.3 Where
17、only one insulation is required, and it can beobtained in sufficient thickness, multiple layers as indicated arenot essential.6.4 Flat block, cut to proper curvature, may be used in placeof preformed pipe insulation. The user should be informedwhen supplying a fabricated product instead of a molded
18、orpreformed pipe insulation, there may result differences inthermal or mechanical performance characteristics of the endproduct.6.5 Any method of forming may be used if the resultingfitting conforms to inside and outside dimensions listed.6.6 Where the body of the flange cover extends overadjacent p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC4502002STANDARDPRACTICEFORFABRICATIONOFTHERMALINSULATINGFITTINGCOVERSFORNPSPIPINGANDVESSELLAGGING

链接地址:http://www.mydoc123.com/p-466603.html