ASTM C430-2017 Standard Test Method for Fineness of Hydraulic Cement by the 45-&x3bc m (No 325) Sieve《用45-&x3bc m (第325号) 筛测定水硬性水泥细度的标准试验方法》.pdf
《ASTM C430-2017 Standard Test Method for Fineness of Hydraulic Cement by the 45-&x3bc m (No 325) Sieve《用45-&x3bc m (第325号) 筛测定水硬性水泥细度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C430-2017 Standard Test Method for Fineness of Hydraulic Cement by the 45-&x3bc m (No 325) Sieve《用45-&x3bc m (第325号) 筛测定水硬性水泥细度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C430 08 (Reapproved 2015)C430 17Standard Test Method forFineness of Hydraulic Cement by the 45-m (No. 325) Sieve1This standard is issued under the fixed designation C430; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the fineness of hydraulic cement by means of the 45-m (No.
3、325) sieve.1.2 The values stated in SI units are to be regarded as the standard. The inch-pound equivalents of SI units may be approximate.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard t
4、o establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision
5、on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C125 Terminology Relating to Concrete and Concrete AggregatesC219 Terminology Relating
6、 to Hydraulic CementE11 Specification for Woven Wire Test Sieve Cloth and Test SievesE161 Specification for Precision Electroformed SievesE177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods3. Terminology3.1 Definitions:3.2 For definitions of terms used in this test method, ref
7、er to Terminology C125 and C219.4. Apparatus4.1 Sieve:4.1.1 Sieve FrameThe sieve frame shall be of metal not subject to corrosion by water and shall be circular, either 51 6 6 mm(2.0 6 0.25 in.) 0.25 in.) when woven-wire cloth is mounted in the frame or 76 6 6 mm (3.0 6 0.25 in.) in diameter when an
8、electroformed sheet is mounted in the frame. The depth of the sieve from the top of the frame to the cloth or sheet shall be 76 66 mm (3.0 6 0.25 in.). The frame shall have either side walls of 89 6 6 mm (3.5 6 0.25 in.) in total height, or legs at least 12mm (0.5 in.) in length, sufficient to allow
9、 air circulation beneath the sieve cloth or electroformed sheet.4.1.2 Sieve Cloth or Electroformed SheetThe sieve frame shall be fitted with either a 45-m (No. 325) stainless steel AISIType 304 woven-wire sieve cloth, conforming to the requirements of Specification E11 or a 45-m electroformed reinfo
10、rced nickelsieve sheet conforming to the requirements of Specification E161 with the exception that the number of openings shall be 71 62 per linear centimetre (180 6 5 per linear inch).4.1.3 Cloth or Sheet Mounting:4.1.3.1 Woven-Wire Cloth MountingType 304 stainless steel woven-type cloth shall be
11、mounted in the frame withoutdistortion, looseness, or wrinkling. For a sieve fabricated by soldering the cloth to the frame, the joint shall be made smooth toprevent the cement from catching in the joints between the sieve cloth and the frame. Two-piece sieves shall clamp tightly on thecloth to prev
12、ent the cement from catching in the joints between the sieve cloth and the frame.1 This test method is under the jurisdiction of ASTM Committee C01 on Cement and is the direct responsibility of Subcommittee C01.25 on Fineness.Current edition approved Oct. 1, 2015Dec. 1, 2017. Published October 2015D
13、ecember 2017. Originally approved in 1959. Last previous edition approved in 20082015as C430 08.C430 08 (2015). DOI: 10.1520/C0430-08R15.10.1520/C0430-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM S
14、tandardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possi
15、ble to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopy
16、right ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.1.3.2 Electroformed Sieve Sheet MountingElectroformed reinforced nickel sieve sheet shall be mounted in the framewithout distortion, looseness, or wrinkling. The joint between the sieve cl
17、oth and the frame shall be made smooth with a materialimpervious to water.4.2 Spray NozzleThe spray nozzle (Fig. 1) shall be constructed of metal not subject to corrosion by water and shall be 17.5mm (0.69 in.) in inside diameter with a central hole drilled in line with the longitudinal axis, an int
18、ermediate row of eight holesdrilled 6 mm (0.23 in.) center-to-center at an angle of 5 from the longitudinal axis, and an outer row of eight holes drilled 11 mm(0.44 in.) center-to-center at an angle of 10 from the longitudinal axis.All holes shall be 0.5 mm (0.02 in.) in diameter. The spraynozzle sh
19、all have been checked within six months prior to testing a cement sample to ensure that the flow rate is between 1500and 3000 g/min at 69 6 3 kPa (10 6 0.4 psi).0.4 psi).4.3 Pressure GageThe pressure gage shall be 76 mm (3.0 in.) (3.0 in.) minimum diameter, and shall be graduated in 7-kPa(1-psi) inc
20、rements, and shall have a maximum capacity of 207 kPa (30 psi). The accuracy at 69 kPa (10 psi) shall be 62 kPa(60.25 psi).(60.25 psi).5. Calibration of 45-m (No. 325) Sieve5.1 Place 1.000 g of the current lot of National Institute of Standards and Technology standard sample No. 114 or No. 46h onthe
21、 clean, dry, 45-m (No. 325) sieve and proceed as in Section 56. The sieve correction factor is the difference between the testresidue obtained and the assigned residue value indicated by the electroformed sheet sieve fineness specified for the standardsample, expressed as a percentage of the test re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC4302017STANDARDTESTMETHODFORFINENESSOFHYDRAULICCEMENTBYTHE45X3BCMNO325SIEVE 45 X3BCM 325 测定 硬性 水泥

链接地址:http://www.mydoc123.com/p-466574.html