1、Designation: C426 151C426 16Standard Test Method forLinear Drying Shrinkage of Concrete Masonry Units1This standard is issued under the fixed designation C426; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1 NOTEEditorially corrected 3.2.1 in February 2016.1. S
3、cope*1.1 This test method covers a routine standardized procedure for determining the linear drying shrinkage of concrete masonryunits or related concrete units under specified accelerated drying conditions.1.2 The text of this test method references notes and footnotes that provide explanatory mate
4、rial. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of the standard.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for infor
5、mation only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulato
6、rylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C490 Practice for Use of Apparatus for the Determination of Length Change of Hardened Cement Paste, Mortar, and ConcreteC1093 Practice for Accreditation of Testing Agencies for MasonryC1232 Terminology of Masonry2.2 ANSI Standard:
7、B94.11M1993 Twist Drills33. Terminology3.1 Terminology defined in Terminology C1232 shall apply for this test method.3.2 Definitions of Terms Specific to This Standard:3.2.1 linear drying shrinkage, nin this test method, the change in linear dimension of the test specimen due to drying froma saturat
8、ed condition to an equilibrium weight and length under specified accelerated drying conditions.4. Significance and Use4.1 This test method is intended to evaluate the drying shrinkage characteristics of a given unit. The results of this laboratorymethod are considered in determining concrete masonry
9、 crack control provisions.NOTE 1The testing laboratory performing this test method should be evaluated in accordance with Practice C1093.5. Apparatus5.1 Strain GaugeThe instruments for measuring linear drying shrinkage shall be so designed as to permit or provide theconditions described in 5.1.1 thr
10、ough 5.1.5.1 This test method is under the jurisdiction ofASTM Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommittee C15.03 on ConcreteMasonry Units and Related Units.Current edition approved Dec. 1, 2015June 1, 2016. Published January 2016July 2016. Originally
11、 approved in 1958. Last previous edition approved in 20102015 asC426 10.C426 151. DOI: 10.1520/C0426-15E01.10.1520/C0426-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, re
12、fer to the standards Document Summary page on the ASTM website.3 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indica
13、tion of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be con
14、sidered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1NOTE 2Strain gauges may be obtained with various gauge lengths. The 10-in. (254-mm) gauge l
15、ength is recommended for use with regular concretemasonry units, however, particular sizes of products may require other lengths. The length of the shrinkage specimen shall not be less than required fora minimum gauge length (distance between gauge plugs) of 6 in. (152.4 mm).5.1.1 A means of positiv
16、e contact with the specimen that will ensure reproducible measurements of length.5.1.2 Means for precise measurement, consisting of a dial micrometer or other measuring device graduated to read in 0.0001-in.(0.0025-mm) units, and accurate within 0.0001 in. (0.0025 mm) in any 0.0010-in. (0.025-mm) ra
17、nge, and within 0.0002 in.(0.0050-mm) in any 0.0100-in. (0.254-mm) range.5.1.3 Sufficient range to allow for small variations in the gauge lengths.NOTE 3If the shrinkage reference points are set carefully to position, a dial micrometer with a travel of 0.2 or 0.3 in. (5.1 or 7.6 mm) provides amplera
18、nge in the instrument.5.1.4 Means for checking the strain gauge at regular intervals against a standard reference bar. The standard reference bar shallbe protected from air currents by placing it inside a wooden box which should be closed except when the strain gauge is beingchecked against it.NOTE
19、4A standard reference bar shall be furnished by the manufacturer of the instrument. A standard bar of ordinary steel is satisfactory, butcorrections must be made for variations in its length due to temperature changes. When a more nearly constant datum is desired, Invar is preferablebecause of its l
20、ow coefficient of thermal expansion.5.1.5 Convenient and rapid measurement of specimens.5.2 ComparatorWhen desirable to measure specimens end to end, a comparator conforming to the requirements of PracticeC490 may be used as an alternative to the strain gauge for measuring linear drying shrinkage.5.
21、3 Gauge PlugsThe gauge plugs shall be made from metal that is resistant to corrosion. Plugs for use with strain gauges shallbe 38 to 12 in. (9.5 to 12.7 mm) in diameter and 12 6 18 (12.7 6 3.2 mm) in thickness. Plugs for use with the comparator shallconsist of 14-in. (6.4-mm) diameter stainless stee
22、l gauge studs shown in Practice C490.5.4 Drying OvenThe oven shall be reasonably airtight and provide the features described in 5.4.1 through 5.4.4.NOTE 5One suggested oven construction is shown in Fig. 1.5.4.1 A minimum storage capacity of three whole test specimens and a clearance of 1 in. (25.4 m
23、m) on all sides of each testspecimen.5.4.2 A constant, uniform temperature of 122 6 2F (50 6 0.9C) throughout the insulated cabinet attained by means of anelectrical heat source (Note 6).NOTE 6Direct heating of test specimens with the combustion products of gas or other carbonaceous fuels is not sat
24、isfactory due to the presence ofcarbon dioxide and water and their possible effect on the drying characteristics of portland cement products.5.4.3 A means of drying specimens to a condition of equilibrium with a relative humidity of 17 6 2 % (Note 7).5.4.3.1 Calcium chloride (CaCl2), if used for thi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC4262016STANDARDTESTMETHODFORLINEARDRYINGSHRINKAGEOFCONCRETEMASONRYUNITS 混凝土 砌块 线性 干燥 收缩 标准 试验 方法

链接地址:http://www.mydoc123.com/p-466563.html