《ASTM C424-1993(2012) Standard Test Method for Crazing Resistance of Fired Glazed Whitewares by Autoclave Treatment 《用热压处理法测定焙烧卫生釉瓷抗破裂性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C424-1993(2012) Standard Test Method for Crazing Resistance of Fired Glazed Whitewares by Autoclave Treatment 《用热压处理法测定焙烧卫生釉瓷抗破裂性的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C424 93 (Reapproved 2012)Standard Test Method forCrazing Resistance of Fired Glazed Whitewares byAutoclave Treatment1This standard is issued under the fixed designation C424; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the crazingresistance of fired glazed whitewares using t
3、he autoclavetreatment and under the conditions specified in this testmethod.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated
4、 with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Significance and Use2.1 This test method is particularly useful for porous mate-rials that can exhibit
5、moisture expansion.2.2 This test method is a primary test method that is suitablefor use in specifications, quality control, and research anddevelopment. It can also serve as a referee test method inpurchasing contracts or agreements.3. Apparatus3.1 AutoclaveAn autoclave built for a steam pressure o
6、f atleast 275 psi (1.9 MPa), and preferably with sufficient capacityto contain at least ten specimens. The apparatus shall beequipped with a safety valve, a blow-off valve, pressure gagemeasuring pressure above atmospheric pressure with an accu-racy of 65 psi (34 kPa), and a source of heat of suffic
7、ientcapacity to ensure a constant steam pressure within theautoclave.4. Number of Specimens4.1 The crazing test shall be made on at least ten identicaluncut specimens having facial dimensions up to and including6 by 6 in. (152 by 152 mm) or 6 by 8 in. (152 by 200 mm). Forlarger specimens, specifical
8、ly tile products, five samples willsuffice and these may be cut to facilitate entry into theautoclave. However, all cut pieces should be as large aspossible and all cut pieces are to be tested.5. Procedure5.1 Placement of Specimens in the AutoclavePlace asufficient amount of distilled water in the a
9、utoclave so that afterthe test a slight excess of water will remain. Place allspecimens on a suitable support at least 2 in. (51 mm) abovethe water line within the autoclave at room temperature. Fastenthe autoclave head securely in place.5.2 Operation of AutoclaveGradually heat the water inthe botto
10、m of the autoclave. Keep the blow-off valve open forseveral minutes after steam begins to escape, thereby expellingmost of the air. After closing the blow-off valve, increase thesteam pressure at a uniform rate until the desired pressure isreached within a period of not less than 45 min nor exceedin
11、g1 h. Apply sufficient heat to maintain the indicated pressureconstant (62 psi (14 kPa) for an additional hour. Shut off theheat source and release the steam pressure immediately byopening the blow-off valve.5.2.1 If it is desirable to ascertain whether failure occurs asa result of rehydration only,
12、 the blow-off valve should becracked only and the steam released slowly over a period of 30min. If this method of steam release is used, the report shall sostate.5.3 Removal of Specimens from AutoclaveLoosen theautoclave head and allow the specimens to cool in place for 30min. Remove the specimens a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC42419932012STANDARDTESTMETHODFORCRAZINGRESISTANCEOFFIREDGLAZEDWHITEWARESBYAUTOCLAVETREATMENT 热压

链接地址:http://www.mydoc123.com/p-466553.html