《ASTM C423-2017 Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method《混响室法测定吸声和吸声系数的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C423-2017 Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method《混响室法测定吸声和吸声系数的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C423 17Standard Test Method forSound Absorption and Sound Absorption Coefficients bythe Reverberation Room Method1This standard is issued under the fixed designation C423; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This test method c
3、overs the measurement of soundabsorption in a reverberation room by measuring decay rate.Procedures for measuring the absorption of a room, theabsorption of an object, such as an office screen, and the soundabsorption coefficients of a specimen of sound absorptivematerial, such as acoustical ceiling
4、 tile, are described.1.2 Field MeasurementsAlthough this test method coverslaboratory measurements, the test method described in 4.1 canbe used for making field measurements of the absorption ofrooms (see also 5.5). A method to measure the absorption ofrooms in the field is described in Test Method
5、E2235.1.3 This test method includes information on laboratoryaccreditation (see Annex A1), asymmetrical screens (see An-nex A2), and reverberation room qualification (see Annex A3).1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstan
6、dard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referen
7、ced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and EnvironmentalAcousticsE795 Practices for Mounting Test Specimens During SoundAbsorption TestsE2235 Test Method for Determination of Decay Rates forUse in Sound Insulation Test Methods2.2 ANSI Standards:S1.6 Preferred Frequenc
8、ies, Frequency Levels, and BandNumbers for Acoustical Measurements3S1.11 Specification for Octave-Band and Fractional-Octave-Band Analog and Digital Filters3S1.26 Method for the Calculation of the Absorption ofSound by the Atmosphere3S1.43 Specifications for Integrating-Averaging Sound LevelMeters32
9、.3 IEC StandardsIEC 61672 ElectroacousticsSound Level MetersPart 1:Specifications32.4 ASTM Adjuncts:Historical Applications Note on Sound Absorber43. Terminology3.1 Except as noted in 3.3, the terms and symbols used inthis test method are defined in Terminology C634. The follow-ing definition is not
10、 currently included in Terminology C634:3.1.1 sound absorption average, SAAa single numberrating, the average, rounded off to the nearest 0.01, of thesound absorption coefficients of a material for the twelveone-third octave bands from 200 through 2500 Hz, inclusive,measured according to this test m
11、ethod.3.1.1.1 DiscussionThe sound absorption coefficients shallbe rounded off to the nearest 0.01 before averaging. If theunrounded average is an exact midpoint, round to the nexthigher multiple of 0.01. For example, report 0.625 as 0.63.3.2 In previous versions of this test method a single numberra
12、ting, called the noise reduction coefficient (NRC), wasdefined as follows:1This test method is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.01 on Sound Absorption.Current edition approved Jan. 15, 2017. Publish
13、ed February 2017. Originallyapproved in 1958. Last previous edition approved 2009 as C423 09a. DOI:10.1520/C0423-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to
14、the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4A drawing of this specimen is available at a nominal charge from ASTMInternational Headquarters. Order Adjunct No. AD
15、JC0423.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment o
16、f International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.19Round the average of the sound absorption coefficientsfor 250, 500, 1000, and 2000 Hz to the nearest multipleof 0.05. If the unrounded average is an exact midpoi
17、nt,round to the next higher multiple of 0.05. For example,0.625 and 0.675 would be reported as 0.65 and 0.70, respectively.9The noise reduction coefficient shall be reported in order toprovide comparison with values reported in the past (see12.1.3).3.3 Definition of Term Specific to This StandardThe
18、following term has the meaning noted for this test method only:3.3.1 output interval, t, T, sof a real-time analyzer, thetime between successive outputs; this time is not necessarilythe same as the integration time.4. Summary of Test Method4.1 Measurement of the Sound Absorption of a Room:4.1.1 A ba
19、nd of random noise is used as a test signal andturned on long enough (about the time for 20 dB decay in thetest band with the smallest decay rate) for the sound pressurelevel to reach a steady state. When the signal is turned off, thesound pressure level will decrease and the decay rate in eachfrequ
20、ency band may be determined by measuring the slope ofa straight line fitted to the sound pressure level of the averagedecay curve. The absorption of the room and its contents iscalculated, based on the assumptions that the incident soundfield is diffuse before and during decay and that no additional
21、energy enters the room during decay, from the Sabine formula:A 5 0.9210Vdc(1)where:A = sound absorption, m2,V = volume of reverberation room, m3,c = speed of sound (calculated according to 11.13), m/sandd = decay rate, dB/s,NOTE 1Previous editions of this test method, which included mixedunits, incl
22、uded the in./lbs unit of sound absorption, the sabin (Sab). Thenumber of sabins is the value of A that would be derived from Eq 1 withthe volume in ft3and the speed of sound in ft/s. This unit finds frequentuse in older literature. One Sab of sound absorption is approximatelyequal to 0.0929 m2of sou
23、nd absorption.These conditions must be fulfilled if the measurement is tohave meaning. The sound absorption calculated according toEq 1 is sometimes called the Sabine absorption.4.1.2 In general, sound absorption is a function of frequencyand measurements are made in a series of frequency bands.4.2
24、Measurement of a Sound Absorption CoeffcientTheabsorption of the reverberation room is measured as outlined in4.1 both before and after placing a specimen of material to betested in the room. The increase in absorption divided by thearea of the test specimen is the dimensionless sound absorptioncoef
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC4232017STANDARDTESTMETHODFORSOUNDABSORPTIONANDSOUNDABSORPTIONCOEFFICIENTSBYTHEREVERBERATIONROOMMETHOD

链接地址:http://www.mydoc123.com/p-466551.html