ASTM C423-2009 Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method.pdf
《ASTM C423-2009 Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method.pdf》由会员分享,可在线阅读,更多相关《ASTM C423-2009 Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C423 09Standard Test Method forSound Absorption and Sound Absorption Coefficients bythe Reverberation Room Method1This standard is issued under the fixed designation C423; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers
3、 the measurement of soundabsorption in a reverberation room by measuring decay rate.Procedures for measuring the absorption of a room, theabsorption of an object, such as an office screen, and the soundabsorption coefficients of a specimen of sound absorptivematerial, such as acoustical ceiling tile
4、, are described.1.2 Field MeasurementsAlthough this test method prima-rily covers laboratory measurements, the test method describedin 4.1 can be used for making field measurements of theabsorption of rooms (see also 5.5). A non-standard method tomeasure the absorption of rooms in the field is descr
5、ibed inAppendix X2.1.3 This test method includes information on laboratoryaccreditation (see Annex A1), asymmetrical screens (see An-nex A2), and reverberation room qualification (see Annex A3).1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
6、It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and EnvironmentalAcousticsE795 Practices
7、 for Mounting Test Specimens During SoundAbsorption Tests2.2 ANSI Standards:S1.6 Preferred Frequencies, Frequency Levels, and BandNumbers for Acoustical Measurements3S1.11 Specification for Octave-Band and Fractional-Octave-Band Analog and Digital Filters3S1.26 Method for the Calculation of the Abso
8、rption ofSound by the Atmosphere3S1.43 Specifications for Integrating Averaging Sound LevelMeters3IEC 61672 ElectroacousticsSound Level MetersPart 1:Specifications32.3 ASTM Adjuncts:Historical Applications Note on Sound Absorber43. Terminology3.1 Except as noted in 3.3, the terms and symbols used in
9、this test method are defined in Terminology C634. The follow-ing definition is not currently included in Terminology C634:3.1.1 sound absorption average, SAAa single numberrating, the average, rounded off to the nearest 0.01, of thesound absorption coefficients of a material for the twelveone-third
10、octave bands from 200 through 2500 Hz, inclusive,measured according to this test method.3.1.1.1 DiscussionThe sound absorption coefficients shallbe rounded off to the nearest 0.01 before averaging. If theunrounded average is an exact midpoint, round to the nexthigher multiple of 0.01. For example, r
11、eport 0.625 as 0.63.3.2 In previous versions of this test method a single numberrating, called the noise reduction coefficient (NRC), wasdefined as follows:9Round the average of the sound absorption coefficientsfor 250, 500, 1000, and 2000 Hz to the nearest multipleof 0.05. If the unrounded average
12、is an exact midpoint,round to the next higher multiple of 0.05. For example,0.625 and 0.675 would be reported as 0.65 and 0.70, respectively.9The noise reduction coefficient shall be reported in order toprovide comparison with values reported in the past see12.1.3).3.3 Definition of Term Specific to
13、 This StandardThefollowing term has the meaning noted for this test method only:1This test method is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.01 on Sound Absorption.Current edition approved Oct. 1, 2009. Pu
14、blished October 2009. Originallyapproved in 1958. Last previous edition approved 2008 as C423 08a. DOI:10.1520/C0423-09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer
15、 to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4A drawing of this specimen is available at a nominal charge from ASTMInternational Headquarters. Order Adjunct No
16、. ADJC0423.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.3.1 output interval, Dt, T, sof a real-time analyzer, thetime between successive outputs; this time is not necessarilythe same as the integration time.4. Summary of Test Me
17、thod4.1 Measurement of the Sound Absorption of a Room:4.1.1 A band of random noise is used as a test signal andturned on long enough (about the time for 20 dB decay in thetest band with the smallest decay rate) for the sound pressurelevel to reach a steady state. When the signal is turned off, theso
18、und pressure level will decrease and the decay rate in eachfrequency band may be determined by measuring the slope ofa straight line fitted to the sound pressure level of the averagedecay curve. The absorption of the room and its contents iscalculated, based on the assumptions that the incident soun
19、dfield is diffuse before and during decay and that no additionalenergy enters the room during decay, from the Sabine formula:A 5 0.9210Vdc(1)where:A = sound absorption, m2or Sab,V = volume of reverberation room, m3or ft3,c = speed of sound (calculated according to 11.13), m/s orft/s, andd = decay ra
20、te, dB/s,These conditions must be fulfilled if the measurement is tohave meaning. The sound absorption calculated according toEq 1 is sometimes called the Sabine absorption.4.1.2 In general, sound absorption is a function of frequencyand measurements are made in a series of frequency bands.4.2 Measu
21、rement of a Sound Absorption CoeffcientTheabsorption of the reverberation room is measured as outlined in4.1 both before and after placing a specimen of material to betested in the room. The increase in absorption divided by thearea of the test specimen is the dimensionless sound absorptioncoefficie
22、nt. In inch-pound units it is reported with the dimen-sionless “unit” sabin per square foot, Sab/ft2.4.3 Measurement of the Sound Absorption of an Object Suchas an Offce Screen, a Theater Chair, or a Space AbsorberThe absorption of the reverberation room is measured asoutlined in 4.1 both before and
23、 after placing one or severalidentical objects in the room. The increase in absorptiondivided by the number of objects is the absorption in squaremeters per object or sabins per object.5. Significance and Use5.1 Measurement of the sound absorption of a room is partof the procedure for other acoustic
24、al measurements, such asdetermining the sound power level of a noise source or thesound transmission loss of a partition. It is also used in certaincalculations such as predicting the sound pressure level in aroom when the sound power level of a noise source in the roomis known.5.2 The sound absorpt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC4232009STANDARDTESTMETHODFORSOUNDABSORPTIONANDSOUNDABSORPTIONCOEFFICIENTSBYTHEREVERBERATIONROOMMETHODPDF

链接地址:http://www.mydoc123.com/p-466549.html