1、Designation: C412M 15Standard Specification forConcrete Drain Tile (Metric)1This standard is issued under the fixed designation C412M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthes
2、es indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers concrete drain tile with inter-nal diamete
3、rs from 100 to 900 mm, that are intended to be usedfor surface and subsurface drainage.1.2 This specification is the metric counterpart of Specifi-cation C412.NOTE 1This specification is a manufacturing and purchase specifica-tion only and does not include requirements for bedding, backfill, or ther
4、elationship between field load condition and the strength classification ofdrain tile. However, experience has shown that the successful performanceof the product depends upon the proper selection of the class of drain tile,type of bedding and backfill, and care that the installation conforms to the
5、construction specifications. The owner is cautioned that he must correlatethe field requirements with the class of drain tile specified and provide foror require inspection at the construction site.2. Referenced Documents2.1 ASTM Standards:2C33/C33M Specification for Concrete AggregatesC150/C150M Sp
6、ecification for Portland CementC260/C260M Specification for Air-Entraining Admixturesfor ConcreteC494/C494M Specification for Chemical Admixtures forConcreteC497M Test Methods for Concrete Pipe, Manhole Sections,or Tile (Metric)C595/C595M Specification for Blended Hydraulic CementsC618 Specification
7、 for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC822 Terminology Relating to Concrete Pipe and RelatedProductsC989/C989M Specification for Slag Cement for Use inConcrete and MortarsC1017/C1017M Specification for Chemical Admixtures forUse in Producing Flowing ConcreteC1116/C
8、1116M Specification for Fiber-Reinforced ConcreteC1602/C1602M Specification for Mixing Water Used in theProduction of Hydraulic Cement Concrete3. Terminology3.1 DefinitionsFor definitions of terms relating to concretepipe, see Terminology C822.4. Classification4.1 Drain tile manufactured according t
9、o this specificationshall be of the following four classes:4.1.1 Standard-Quality Concrete Drain Tile, intended forland drainage of ordinary soils where the tile are laid intrenches of moderate depths and widths. Standard-Qualityconcrete drain tile are not recommended for use where internaldiameters
10、 in excess of 300 mm are required.4.1.2 Extra-Quality Concrete Drain Tile, intended for landdrainage of ordinary soils where the tile are laid in trenches ofconsiderable depths or widths, or both.4.1.3 Heavy-Duty Extra-Quality Concrete Drain Tile, in-tended for land drainage of ordinary soils where
11、the tile are laidin trenches of large depths or widths, or both.4.1.4 Special-Quality Concrete Drain Tile, intended for landdrainage where special precautions are necessary for concretetile laid in soils that are markedly acid or contain unusualquantities of sulfates (see Section 7), and where the t
12、ile are laidin trenches of considerable depths or widths, or both.4.1.4.1 Where the calculated loads are in excess of thecrushing strengths prescribed in the physical requirements forextra-quality and special-quality concrete drain tile, tilestrengths must be specified in advance by the owner.5. Bas
13、is of Acceptance5.1 The acceptability of drain tile shall be determined by (1)the results of the physical tests as specified in Section 8, and inTest Methods C497M,(2) measurements and inspection toascertain whether the tile conform to the requirements regard-ing dimensions, shape, and freedom from
14、visible defects, and(3) the manufacturers certification in writing that the tile havebeen made in accordance with any special provisions, such as1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.01 onNon-Reinforce
15、d Concrete Sewer, Drain and Irrigation Pipe.Current edition approved Oct. 1, 2015. Published October 2015. Originallyapproved in 1980. Last previous edition approved in 2011 as C412M 11. DOI:10.1520/C0412M-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custom
16、er Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1strength, absorption, permeability, ty
17、pe of cement, admixture,curing conditions, etc.5.2 The owner shall specify in writing the class or classes ofconcrete tile to be supplied, whether Standard-Quality, Extra-Quality, Heavy-Duty Extra-Quality, or Special-Quality. UnlessExtra-Quality, Heavy-Duty Extra-Quality, or Special-Qualityconcrete
18、drain tile have been specified, Standard-Quality draintile shall be accepted.6. Materials6.1 ConcreteThe concrete shall consist of cementitiousmaterials, mineral aggregates, admixtures, if used, and water.6.2 Cementitious Materials:6.2.1 CementCement shall conform to the requirementsfor portland cem
19、ent of Specification C150/C150M or shall beportland blast-furnace slag cement, portland-limestone cement,or portland-pozzolan cement conforming to the requirementsof Specification C595/C595M, except that the pozzolan con-stituent in the Type IP portland-pozzolan cement shall be flyash.6.2.2 Fly AshF
20、ly ash shall conform to the requirements ofSpecification C618, Class F or Class C.6.2.3 Slag CementSlag cement shall conform to the re-quirements of Grade 100 or 120 of Specification C989/C989M.6.2.4 Allowable Combinations of Cementitious MaterialsThe combination of cementitious materials used in th
21、e concreteshall be one of the following:6.2.4.1 Portland cement only,6.2.4.2 Portland blast-furnace slag cement only,6.2.4.3 Portland-pozzolan cement only,6.2.4.4 Portland-limestone cement only,6.2.4.5 A combination of portland cement or portland-limestone cement and fly ash,6.2.4.6 A combination of
22、 portland cement or portland-limestone cement and slag cement,6.2.4.7 A combination of portland cement or portland-limestone cement, fly ash, and slag cement, or6.2.4.8 A combination of portland-pozzolan cement and flyash.6.3 AggregatesAggregates shall conform to the require-ments of Specification C
23、33/C33M, except that the require-ments for gradation shall not apply.6.4 AdmixturesThe following admixtures and blends areallowable:6.4.1 Air-entraining admixture conforming to SpecificationC260/C260M;6.4.2 Chemical admixture conforming to SpecificationC494/C494M;6.4.3 Chemical admixture for use in
24、producing flowingconcrete conforming to Specification C1017/C1017M; and6.4.4 Chemical admixture or blend approved by the owner.6.5 FibersSynthetic fibers and nonsynthetic fibers shall beallowed to be used, at the manufacturers option, in concretepipe as a nonstructural manufacturing material. Synthe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC412M2015STANDARDSPECIFICATIONFORCONCRETEDRAINTILEMETRIC 混凝土 排水管 标准 规格 米制 PDF

链接地址:http://www.mydoc123.com/p-466517.html