ASTM C398-1998(2003) Standard Practice for Use of Hydraulic Cement Mortars in Chemical-Resistant Masonry《耐化学腐蚀的水硬性水泥灰浆的使用的标准实施规程》.pdf
《ASTM C398-1998(2003) Standard Practice for Use of Hydraulic Cement Mortars in Chemical-Resistant Masonry《耐化学腐蚀的水硬性水泥灰浆的使用的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C398-1998(2003) Standard Practice for Use of Hydraulic Cement Mortars in Chemical-Resistant Masonry《耐化学腐蚀的水硬性水泥灰浆的使用的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 398 98 (Reapproved 2003)Standard Practice for Use ofHydraulic Cement Mortars in Chemical-Resistant Masonry1This standard is issued under the fixed designation C 398; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides recommendations for use ofhydraulic cement mortars for chemical-resistant masonry co
3、n-struction.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.3
4、 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information only.2. Referenced Documents2.1 ASTM Standards:2C 144 Specification for Aggregate for Masonry MortarC 150 Specification for Portland CementC 171 Specification for She
5、et Materials for Curing ConcreteC 267 Test Method for Chemical Resistance of Mortars,Grouts, and Monolithic Surfacings and Polymer ConcretesC 279 Specification for Chemical-Resistant Masonry UnitsC 309 Specification for Liquid Membrane-Forming Com-pounds for Curing ConcreteC 404 Specification for Ag
6、gregates for Masonry GroutC 595 Specification for Blended Hydraulic CementsC 904 Terminology Relating to Chemical-Resistant Non-metallic MaterialsD 226 Specification for Asphalt-Saturated Organic FeltUsed in Roofing and WaterproofingD 227 Specification for Coal-Tar Saturated Organic FeltUsed in Roof
7、ing and Waterproofing3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, see Terminology C 904.FLOORS AND CONSTRUCTION UNITS4. Preparation of Concrete Fill or Subbase4.1 In new construction, the surface of the concrete fill shallbe free of mortar drippings, projecting joint
8、s, etc. Smoothsurfaces resulting from the use of plywood forms or a steeltrowel finish are not acceptable and must be given a coursesandpaper profile by blasting or mechanical scarifying. Thepreferred finish for new concrete floors after leveling is a woodfloat finish, followed by a single pass meta
9、l trowel finish. Thecontour of the finished surface must be free of ridges anddepressions, cracks, or open joints. When an old concretesurface is to be removed, it shall be cut out to provide thenecessary thickness for the new setting bed and the construc-tion unit. The surface must be clean, free o
10、f loose particles,hard, and roughened to ensure intimate bond with the new bedjoint. The edges around all cut-out sections shall be maintainedstraight and vertical. A final finishing of the edges by handchiseling may be necessary.4.2 A cleavage membrane consisting of waterproof buildingfelt as speci
11、fied in Specifications D 226 and D 227, or poly-ethylene sheeting 0.004 in. (0.10 mm) thick is generally usedover wood frame construction and is preferred for many othertypes of construction. It may be omitted over certain types ofconcrete bases of limited areas. Cleavage membrane shall haveedges ov
12、erlapped a nominal 2-in.4.3 CleaningAll dirt, dust, loose particles, surfacelaitance, and debris shall be removed from the concrete fill orsubbase by vigorous brooming, vacuuming, or other means.The surface must be free of grease, oil, or wax deposits.4.4 Screed StripsWood or metal strips shall be u
13、sed togage the thickness of the setting bed.4.5 Thickness of Setting BedThe setting bed shall be 1 to112 in. (25 to 38 mm) thick.4.6 Wetting Concrete Fill or SubbaseSeveral hours beforeplacing the setting bed, the prepared concrete surface shall bethoroughly saturated with clean water. About 1 h bef
14、ore1This practice is under the jurisdiction of ASTM Committee C03 on Chemical-Resistant Nonmetallic Materials and is the direct responsibility of SubcommitteeC03.02 on Mortar and Monolithics.Current edition approved Oct. 1, 2003. Published October 2003. Originallyapproved in 1957. Last previous edit
15、ion approved in 1998 as C 398 98.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM Internationa
16、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.placing the topping, all surface water shall be removed with amop or by other means.NOTE 1The procedure described in this paragraph does not apply tofloors installed over a cleavage membrane.4.7 Expansion JointsWh
17、en required, the expansion jointstrips shall be located and set in position. If the expansionjoints are not of the preset type, removable strips shall be set soas to keep the joints free of dirt and mortar.5. Cement Paste Slush Coat5.1 About 15 min before placing the setting bed, theconcrete slab su
18、rface shall be given a slush coat of grout. Thegrout shall consist of either neat cement and water, or cement,sand, and water. The slush coat shall not be spread over such alarge area that it will dry out before the setting bed is placed tocover it. The consistency of the slush coat shall be similar
19、 tothat of thick cream, and its thickness shall not exceed116 in.(1.6 mm).NOTE 2The procedure described in this section does not apply tofloors installed over a cleavage membrane.6. Materials and Manufacture6.1 Portland and Portland Blast-Furnace Slag CementsSee Specifications C 150 and C 595. No ca
20、lcium aluminatecement, lime, or admixture shall be mixed with these cements,in the mortar batch or in the mixing water.6.2 Calcium Aluminate CementNo portland or portlandblast-furnace slag cements, lime, or admixture shall be mixedwith this cement, in the mortar batch or in the mixing water.6.3 Aggr
21、egateThe aggregate shall be in accordance withSpecification C 144 or C 404, or both.6.4 BrickThese mortars may be used with masonry unitsof brick (clay or shale) meeting the requirements of Specifi-cation C 279, and with tile masonry units. The brick shall beclean and protected from frost damage. Br
22、icks shall be wettedseveral hours before laying, unless their gain in weightresulting from partial immersion flatwise in18 in. (3 mm) ofwater for 1 min is less than34 oz/30 in.2(0.11 g/cm2)ofimmersed area. There shall be no free water on the bricks whenlaid.6.5 WaterThe mixing water shall be approxi
23、mately neu-tral and shall be potable.6.6 Metal ReinforcingIf reinforcing is used, it shall bewelded wire fabric 2 by 2 in. (50 by 50 mm), and 16 by16-gage (0.65 by 0.65-mm), or expanded metal reinforcing notless than 1.8 lb/yd2(1.0 kg/m2).6.7 Expansion JointsWhen required, expansion jointcompound or
24、 premolded joints shall be as specified.7. Proportions7.1 The setting bed shall consist of one bag of cement and3ft3(0.085 m3) of sand (Note 3). For ordinary groutingconditions, the grout shall contain one bag of cement and 2 ft3(0.057 m3) of sand (Note 3); but for thin joints where a finersand is u
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC39819982003STANDARDPRACTICEFORUSEOFHYDRAULICCEMENTMORTARSINCHEMICALRESISTANTMASONRY 化学 腐蚀 硬性 水泥

链接地址:http://www.mydoc123.com/p-466472.html