《ASTM C374-1970(2009) Standard Test Methods for Fusion Flow of Porcelain Enamel Frits (Flow-Button Methods)《搪瓷玻璃熔化流动性的标准试验方法(流动按钮法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C374-1970(2009) Standard Test Methods for Fusion Flow of Porcelain Enamel Frits (Flow-Button Methods)《搪瓷玻璃熔化流动性的标准试验方法(流动按钮法)》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 374 70 (Reapproved 2009)Standard Test Methods forFusion Flow of Porcelain Enamel Frits (Flow-ButtonMethods)1This standard is issued under the fixed designation C 374; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover evaluation of the relativefusion flow characteristics of samples of a given porcel
3、ainenamel frit by comparison with an established standard for thatfrit.1.2 Two test methods are included, differing only in certaindetails of the samples and in the apparatus and procedure forpreparation of test specimens. Both test methods give equallyreproducible results and provide a satisfactory
4、 basis for com-parison of fusion flow of the sample with that of the establishedstandard.1.2.1 Test Method A employs granular particles of frit towhich a bonding agent has been added. Button specimens areformed under high pressure in a hydraulic press.1.2.2 Test Method B employs crushed, sized parti
5、cles of fritto which a bonding agent has been added. Button specimensare formed in a steel mold by hand.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not c
6、onsidered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to
7、use.2. Referenced Document2.1 ASTM Standards:2E11 Specification for Woven Wire Test Sieve Cloth andTest SievesTEST METHOD A3. Apparatus3.1 Mortar, of hard steel, resistant to abrasion by theporcelain enamel frit, and conforming to the dimensions shownin Fig. 1.NOTE 1Suitable mortars are available co
8、mmercially under the desig-nation “tool steel crushing mortar.”3.2 SievesNo. 12 (1.70-mm) and No. 200 (75-m) sievesconforming to Specification E11.NOTE 2Tyler Standard Series sieves No. 12 (0.0060-in. (0.152-mm)openings) and No. 200 (0.029-in. (0.07-mm) openings) correspond toASTM sieves Nos. 12 and
9、 200 (U.S. Standard Sieves series numbers).3.3 Hydraulic Press, capable of developing 3500-lbf(15 600 N) force (Fig. 2).3.4 Steel Mold Assembly, consisting of a die and plunger,and having an inside diameter of12 in. (12.7 mm) over itslength of 218 in. (54 mm) as illustrated in Fig. 3.3.5 Fusion Flow
10、 Rack, preferably constructed of heat-resisting alloy and conforming to the detailed requirementsshown in Fig. 4.4. Sample4.1 A representative sample of the frit to be tested shall beobtained, mixed thoroughly, and reduced by quartering toabout 25 g. This sample shall be crushed in a hard steel mort
11、arto pass a No. 12 (1.70-mm) sieve and be retained on a No. 200(75-m) sieve.5. Test Specimen5.1 Weigh 3.5 6 0.05-g samples of the standard frit and ofthe material to be tested and thoroughly mix each of thesesamples with 4 or 5 drops of a 1 % gum arabic solution. Moldfusion button test specimens of
12、the standard and of the sampleas directed in 5.2.1These test methods are under the jurisdiction of ASTM Committee B08 onMetallic and Inorganic Coatings and are the direct responsibility of SubcommitteeB08.12 on Materials for Porcelain Enamel and Ceramic-Metal Systems.Current edition approved April 1
13、5, 2009. Published June 2009. Originallyapproved in 1955. Last previous edition approved in 2004 as C 374 70 (2004)1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to
14、 the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Place the sample in the steel mold. Place the moldassembly containing the sample in a hydraulic press and bringthe press up t
15、o 3000 to 3500 lbf (13.3 to 15.6 kN) total load,and immediately release (Fig. 2). Force the formed button outof the mold with the plunger, taking care not to damage thebutton in any way that might change the dimensions.5.3 Dry the test specimens in a suitable oven at 100C for 1h.NOTE 3Special care m
16、ust be exercised in drying buttons formed bythis method, before firing, in order to prevent bloating and possibleeruption of the button when first placed in the furnace.6. Procedure6.1 MountingPlace the dried fusion buttons on a firedgroundcoat plate. The location of the test specimens withrespect t
17、o the standard may be modified as desired. Althoughthe gage of metal used for the ground-coated plate is not ofcritical importance, most satisfactory results will be obtainedwhen the metal is not heavier than 18 gage nor lighter than 22gage (1.02 to 0.044 mm). Use the same gage of metalconsistently
18、from test to test in order to reduce the number ofvariables to a minimum. The groundcoat enamel used to coatthe groundcoat plate shall have a median firing temperature nomore than 50F (28C) below the median firing temperature forthe most refractory frit being tested. Place the groundcoat platewith f
19、usion buttons in place in a horizontal position on thefusion flow rack, which shall previously have been heated tofurnace temperature, and place the entire test assembly in thefurnace immediately.6.2 FiringFire in a furnace in which the atmosphere isoxidizing and entirely free of any products of com
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC37419702009STANDARDTESTMETHODSFORFUSIONFLOWOFPORCELAINENAMELFRITSFLOWBUTTONMETHODS 搪瓷 玻璃 熔化 流动性

链接地址:http://www.mydoc123.com/p-466413.html