ASTM C315-2007(2011) Standard Specification for Clay Flue Liners and Chimney Pots《粘土烟道衬里和烟囱顶管用标准规格》.pdf
《ASTM C315-2007(2011) Standard Specification for Clay Flue Liners and Chimney Pots《粘土烟道衬里和烟囱顶管用标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C315-2007(2011) Standard Specification for Clay Flue Liners and Chimney Pots《粘土烟道衬里和烟囱顶管用标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C315 07 (Reapproved 2011)Standard Specification forClay Flue Liners and Chimney Pots1This standard is issued under the fixed designation C315; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification establishes the criteria for acce
3、ptance,prior to installation, of clay flue liners and chimney pots usedfor conveying hot gases in masonry chimneys.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyan
4、d are not considered standard.1.3 For installation of clay flue liners, see Practice C1283.2. Referenced Documents2.1 ASTM Standards:2C67 Test Methods for Sampling and Testing Brick andStructural Clay TileC301 Test Methods for Vitrified Clay PipeC896 Terminology Relating to Clay ProductsC1283 Practi
5、ce for Installing Clay Flue Lining3. Terminology3.1 DefinitionsClay, fire clay, shale, and surface clay areas defined in Terminology C896.3.1.1 chimney pota pipe used at the top of the chimney toincrease draft and carry off smoke.4. Classification4.1 TypesFlue liners acceptable under this specificat
6、ionshall be designated as rectangular nonmodular, rectangularmodular, round or oval.5. Materials and Manufacture5.1 Flue liners and chimney pots shall be manufacturedfrom fire clay, shale, surface clay, or a combination of thesematerials that when formed and fired to suitable temperatures,shall yiel
7、d a product that is strong, durable, serviceable, andconforms to this specification.6. Physical and Chemical Requirements6.1 Absorption:6.1.1 The absorption of clay flue liners and chimney potsshall not exceed 8.0 % when tested in accordance with TestMethods C301.6.1.2 Test SpecimensFive dry test sp
8、ecimens shall beobtained from the five flue liners or chimney pots to be testedand shall measure as closely as possible to 4 by 4 in. (100 by100 mm) per side. All rough edges shall be ground off andloose particles removed.6.1.3 If any of the test specimens fail to meet the require-ments, the manufac
9、turer shall be allowed to retest on twoadditional specimens for each one that failed. The flues andpots will be acceptable if all the subsequent specimens forretest meet the requirements.6.2 Acid Resistance:6.2.1 This is a test used to determine the resistance of clayflue liners and chimney pots to
10、the action of acids encounteredin chimneys. This test shall be performed only when specified.6.2.2 The flue liner and chimney pots shall be acceptable ifthe acid soluble material does not exceed 0.25 % when testedin accordance with Test Methods C301.6.2.3 Test SpecimensSelect one test specimen from
11、eachsize of flue liner or chimney pot. The specimens shall measureabout 2 by 2 in. (51 by 51 mm) per side and weigh not morethan 200 g. They shall be sound pieces with all edges freshlybroken, free of cracks or shattered edges, and shall bethoroughly cleaned.6.3 Freeze-Thaw Cycle Test:6.3.1 When flu
12、e liners or chimney pots are tested in accor-dance with Test Methods C67, Section 9 on structural clay tile,there shall be no breakage and the percentage of weight lossshall not exceed 0.5 %.6.3.2 Test SpecimensFive dry test specimens shall beobtained from the five flue liners or chimney pots to be
13、testedand shall measure as closely as possible to 4 by 4 in. (100 by100 mm) per side. All rough edges shall be ground off andloose particles removed.1This specification is under the jurisdiction of ASTM Committee C04 onVitrified Clay Pipe and is the direct responsibility of Subcommittee C04.20 onMet
14、hods of Test and Specifications.Current edition approved Nov. 1, 2011. Published January 2012. Originallyapproved in 1953. Last previous edition approved in 2007 as C315 07. DOI:10.1520/C0315-07R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service
15、at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Sizes and Dimensions7.1 Flue liners shall be
16、specified and furnished in thedimensions prescribed in Tables 1-4. When other sizes arerequired, flue liners that meet the requirements of Sections 5and 6 shall be cut and installed in the chimney.7.2 Variations in dimensions in Tables 1-4 shall not exceed612 in. (613 mm) for outside dimensions. Per
17、missible wallthickness variation is 618 in. (63 mm) for all flue liners,except that there shall be no limit for plus variation in roundflue liners. Variations in dimensions of round flue lining shallnot exceed those shown in Table 3. The maximum difference inthe diagonal dimensions of rectangular mo
18、dular flue linersshall not exceed12 in. (13 mm) for sizes up to and including 12by 12 in. (305 by 305 mm) and34 in. (19 mm) for larger sizes.7.3 Dimensions in Tables 1-4 are not to be used to determinethe effective area of the flue liner. Consult manufacturer or useactual measurements to determine e
19、ffective areas of the linersfor sizing purposes.7.4 Flue liners are available in various lengths. The varia-tion in length shall not exceed 614 in./ft (621 mm/m). Themaximum difference in length of the opposite sides of flueliners shall not exceed14 in./ft (21 mm/m) of length.8. Workmanship, Finish,
20、 and Appearance8.1 Flue liners and chimney pots shall be well burned andsubstantially free of laminations.8.2 Blisters shall not exceed 3 in. (76 mm) in diameter, andblisters or pimples shall not project more than18 in. (3 mm)above the surface, in sizes up to and including 1734 by 1734 in.(450 by 45
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC31520072011STANDARDSPECIFICATIONFORCLAYFLUELINERSANDCHIMNEYPOTS 粘土 烟道 衬里 烟囱 管用 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-466266.html