ASTM C285-2010(2015)e1 Standard Test Methods for Sieve Analysis of Wet-Milled and Dry-Milled Porcelain Enamel《湿磨和干磨搪瓷粉的筛选分析标准试验方法》.pdf
《ASTM C285-2010(2015)e1 Standard Test Methods for Sieve Analysis of Wet-Milled and Dry-Milled Porcelain Enamel《湿磨和干磨搪瓷粉的筛选分析标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C285-2010(2015)e1 Standard Test Methods for Sieve Analysis of Wet-Milled and Dry-Milled Porcelain Enamel《湿磨和干磨搪瓷粉的筛选分析标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C285 10 (Reapproved 2015)1Standard Test Methods forSieve Analysis of Wet-Milled and Dry-Milled PorcelainEnamel1This standard is issued under the fixed designation C285; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTESections 4 and 10 corrected editorially in May 2015.INTRODUCTIONThese test methods provide a rapid means of determ
3、ining the fineness of glass frit in wet- ordry-milled porcelain enamel coating materials by sieve analysis. Fineness is a key predicator offusibility, tearing, gloss, opacity, suspension in the slip, and ease of spraying because of the directrelationship to surface area.1. Scope1.1 These test method
4、s cover the determination of thefineness of frit in wet- or dry-milled porcelain enamels andother ceramic coatings for metals by means of the No. 200(75-m) or No. 325 (45-m) sieve.1.2 The two methods appear as follows:SectionsMethod AReferee MethodMethod BRoutine Method4to910 to 141.3 Method A is in
5、tended for use where a referee method ofhigher accuracy is required, while Method B is intended tomeet the needs of normal enamel plant production controloperations where a rapid, simplified method of sieve testing isrequired. The accuracy of the simplified method has proved tobe entirely adequate f
6、or this use. The simplified test, however,is not recommended where high accuracy is required.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health prac
7、tices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Significance and Use3.1 The fineness of the frit has a direct bearing on many ofits properties, such as fusibili
8、ty, tearing, gloss, opacity, suspen-sion in the slip, and ease of spraying.METHOD AREFEREE METHOD4. Apparatus4.1 BalanceThe balance or scale shall be of at least 500-gcapacity, and accurate to 0.1 g.4.2 SievesThe sieves shall conform to Specification E11.They shall include the No. 40 (425-m) sieve a
9、nd also the No.200 (75-m) or the No. 325 (45-m) sieve, or both. A No. 325sieve shall be used when the fineness is such that, from asample containing 100 g of dry solids, less than2gisretainedon a No. 200 sieve. An 8-in. (203-mm) full-height sieve isrecommended. This height is preferred because there
10、 is lesstendency to flood or splash, and also because it fits commercialautomatic tapping and shaking machines. All sieves used for1These test methods are under the jurisdiction of ASTM Committee B08 onMetallic and Inorganic Coatings and are the direct responsibility of SubcommitteeB08.12 on Materia
11、ls for Porcelain Enamel and Ceramic-Metal Systems.Current edition approved May 1, 2015. Published May 2015. Originallyapproved in 1951. Last previous edition approved in 2010 as C285 10. DOI:10.1520/C0285-10R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cust
12、omer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1testing shall be standardized initia
13、lly and after every 50 testsagainst a reference sieve tested by the National Bureau ofStandards and bearing its precision seal. The correction for thesieve used in this test shall be determined by sieving tests madein conformity with the procedure of this test method. Identicalsamples shall be sieve
14、d through the reference sieve and the testsieve. Test materials shall be chosen so that 5 to 10 % of thematerial will be retained on the reference sieve. The differencebetween the percentage residue on the reference sieve and thaton the test sieve is the amount of correction which shall bealgebraica
15、lly added to, or subtracted from, the correction forthe reference sieve to obtain the final correction (Note 1). TheNo. 40 sieve need not be calibrated.NOTE 1For example, when comparing the reference sieve with a testsieve, should 8.5 g be retained on the reference sieve and 7.5 g on the testsieve,
16、the total correction for the test sieve would then be 8.5 7.5,or + 1.0.4.3 DryerA suitable means for drying the sieves and slipsample, without exceeding a temperature of 250F (122C),shall be provided. No dryer is needed for sieve tests ofdry-milled enamel.4.4 Mechanically Operated Sieve Shaker The m
17、echanicalshaking device shall be such as to produce a lateral and verticalmotion of the sieve, accompanied by a jarring action so as tokeep the sample moving continuously over the surface of thesieve. If a machine shaker is to be used, the thoroughness ofsieving shall be tested by comparing and cali
18、brating with thehand method of sieving, as described in Section 6.5. Sample5.1 Wet-Milled EnamelSelect a sample of slip representa-tive of the material to be tested. Protect samples from evapo-ration. Determine the water content of the slip by drying arepresentative 100-g sample of slip to constant
19、weight at atemperature not exceeding 250F (122C). Pass the samplethrough a No. 40 sieve before weighing, and discard thematerial retained on the sieve. Sample the slip after stirring byweighing out to the nearest 0.1 g, a quantity calculated tocontain 100 g of dry solids.5.2 Dry-Milled EnamelSelect
20、a sample representative ofthe material to be tested and containing 100 g of dry solids,weighed to the nearest 0.1 g.6. Procedure for Wet-Milled Enamel6.1 Wet SievingTransfer the weighed sample to the No.200 or No. 325 sieve. Wash the sample through the sieve witha gentle flow of water from a rubber
21、hose until the waterpassing through the sieve appears clear and free of cloudiness.This usually requires 2 min. Exercise care to prevent any lossof sample because of splashing or overflowing. Dry the sievewith its residue until the residue easily moves about as a drypowder when the sieve is shaken.
22、Complete the sieving andweighing operation in accordance with 6.2 or 6.3. Make tests induplicate.6.2 Hand SievingHold the sieve, with pan and coverattached, in one hand at an angle of about 20 from thehorizontal. Move the sieve up and down in the plane ofinclination at a rate of about 150 times per
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC28520102015E1STANDARDTESTMETHODSFORSIEVEANALYSISOFWETMILLEDANDDRYMILLEDPORCELAINENAMEL 搪瓷 筛选 分析

链接地址:http://www.mydoc123.com/p-466183.html