ASTM C285-1988(2005) Standard Test Methods for Sieve Analysis of Wet-Milled and Dry-Milled Porcelain Enamel《湿磨和干磨搪瓷粉的筛选分析试验方法》.pdf
《ASTM C285-1988(2005) Standard Test Methods for Sieve Analysis of Wet-Milled and Dry-Milled Porcelain Enamel《湿磨和干磨搪瓷粉的筛选分析试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C285-1988(2005) Standard Test Methods for Sieve Analysis of Wet-Milled and Dry-Milled Porcelain Enamel《湿磨和干磨搪瓷粉的筛选分析试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 285 88 (Reapproved 2005)Standard Test Methods forSieve Analysis of Wet-Milled and Dry-Milled PorcelainEnamel1This standard is issued under the fixed designation C 285; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination of thefineness of frit in wet- or dry-milled porcelain enamels
3、 andother ceramic coatings for metals by means of the No. 200(75-m) or No. 325 (45-m) sieve.1.2 The two methods appear as follows:SectionsMethod AReferee MethodMethod BRoutine Method4to910 to 141.3 Method A is intended for use where a referee method ofhigher accuracy is required, while Method B is i
4、ntended tomeet the needs of normal enamel plant production controloperations where a rapid, simplified method of sieve testing isrequired. The accuracy of the simplified method has proved tobe entirely adequate for this use. The simplified test, however,is not recommended where high accuracy is requ
5、ired.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referen
6、ced Documents2.1 ASTM Standards:2E11 Specification for Wire Cloth and Sieves for TestingPurposes3. Significance and Use3.1 The fineness of the frit has a direct bearing on many ofits properties, such as fusibility, tearing, gloss, opacity, suspen-sion in the slip, and ease of spraying.METHOD AREFERE
7、E METHOD4. Apparatus4.1 BalanceThe balance or scale shall be of at least 500-gcapacity, and accurate to 0.1 g.4.2 SievesThe sieves shall conform to Specification E11.They shall include the No. 40 (425-m) sieve and also the No.200 (75-m) or the No. 325 (45-m) sieve (Note 1), or both. ANo. 325 sieve s
8、hall be used when the fineness is such that, froma sample containing 100 g of dry solids, less than2gisretained on a No. 200 sieve. An 8-in. (203-mm) full-heightsieve is recommended. This height is preferred because there isless tendency to flood or splash, and also because it fitscommercial automat
9、ic tapping and shaking machines. Allsieves used for testing shall be standardized initially and afterevery 50 tests against a reference sieve tested by the NationalBureau of Standards and bearing its precision seal. Thecorrection for the sieve used in this test shall be determined bysieving tests ma
10、de in conformity with the procedure of this testmethod. Identical samples shall be sieved through the referencesieve and the test sieve. Test materials shall be chosen so that5 to 10 % of the material will be retained on the referencesieve. The difference between the percentage residue on thereferen
11、ce sieve and that on the test sieve is the amount ofcorrection which shall be algebraically added to, or subtractedfrom, the correction for the reference sieve to obtain the finalcorrection (Note 2). The No. 40 sieve need not be calibrated.NOTE 1Tyler Standard Sieves of 35, 200, and 325 mesh corresp
12、ond,respectively, to ASTM sieves No. 40, 200, and 325 (U.S. Standard SieveSeries numbers).NOTE 2For example, when comparing the reference sieve with a testsieve, should 8.5 g be retained on the reference sieve and 7.5 g on the testsieve, the total correction for the test sieve would then be 8.5 7.5,
13、or + 1.0.4.3 DryerA suitable means for drying the sieves and slipsample, without exceeding a temperature of 250F (122C),shall be provided. No dryer is needed for sieve tests ofdry-milled enamel.4.4 Mechanically Operated Sieve Shaker The mechanicalshaking device shall be such as to produce a lateral
14、and verticalmotion of the sieve, accompanied by a jarring action so as to1These test methods are under the jurisdiction of ASTM Committee B08 onMetallic and Inorganic Coatings and are the direct responsibility of SubcommitteeB08.12 on Materials for Porcelain Enamel and Ceramic-Metal Systems.Current
15、edition approved Sept. 15, 2005. Published September 2005. Originallyapproved in 1951. Last previous edition approved in 1999 as C 285 88 (1999).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards
16、volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.keep the sample moving continuously over the surface of thesieve. If a machine shaker is to be used,
17、the thoroughness ofsieving shall be tested by comparing and calibrating with thehand method of sieving, as described in Section 6.5. Sample5.1 Wet-Milled EnamelSelect a sample of slip represen-tative of the material to be tested. Protect samples fromevaporation. Determine the water content of the sl
18、ip by dryinga representative 100-g sample of slip to constant weight at atemperature not exceeding 250F (122C). Pass the samplethrough a No. 40 sieve before weighing, and discard thematerial retained on the sieve. Sample the slip after stirring byweighing out to the nearest 0.1 g, a quantity calcula
19、ted tocontain 100 g of dry solids.5.2 Dry-Milled EnamelSelect a sample representative ofthe material to be tested and containing 100 g of dry solids,weighed to the nearest 0.1 g.6. Procedure for Wet-Milled Enamel6.1 Wet SievingTransfer the weighed sample to the No.200 or No. 325 sieve. Wash the samp
20、le through the sieve witha gentle flow of water from a rubber hose until the waterpassing through the sieve appears clear and free of cloudiness.This usually requires 2 min. Exercise care to prevent any lossof sample because of splashing or overflowing. Dry the sievewith its residue until the residu
21、e easily moves about as a drypowder when the sieve is shaken. Complete the sieving andweighing operation in accordance with 6.2 or 6.3. Make tests induplicate.6.2 Hand SievingHold the sieve, with pan and coverattached, in one hand at an angle of about 20 from thehorizontal. Move the sieve up and dow
22、n in the plane ofinclination at a rate of about 150 times per minute, and strikeagainst the palm of the other hand at the top of each stroke.After every 25 strokes, turn the sieve about one sixth of arevolution in the same direction. Continue the operation untilnot more than 0.05 g passes through th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC28519882005STANDARDTESTMETHODSFORSIEVEANALYSISOFWETMILLEDANDDRYMILLEDPORCELAINENAMEL 搪瓷 筛选 分析 试验

链接地址:http://www.mydoc123.com/p-466181.html