ASTM C270-2012a Standard Specification for Mortar for Unit Masonry《砖块工程用灰浆的标准规格》.pdf
《ASTM C270-2012a Standard Specification for Mortar for Unit Masonry《砖块工程用灰浆的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C270-2012a Standard Specification for Mortar for Unit Masonry《砖块工程用灰浆的标准规格》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C270 12aStandard Specification forMortar for Unit Masonry1This standard is issued under the fixed designation C270; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses ind
2、icates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specification covers mortars for use in the construc-tion of non-reinforc
3、ed and reinforced unit masonry structures.Four types of mortar are covered in each of two alternativespecifications: (1) proportion specifications and (2) propertyspecifications.NOTE 1When the property specification is used to qualify masonrymortars, the testing agency performing the test methods sh
4、ould beevaluated in accordance with Practice C1093.1.2 The proportion or property specifications shall govern asspecified.1.3 When neither proportion or property specifications arespecified, the proportion specifications shall govern, unlessdata are presented to and accepted by the specifier to show
5、 thatmortar meets the requirements of the property specifications.1.4 The text of this specification references notes andfootnotes which provide explanatory material. These notes andfootnotes (excluding those in tables and figures) shall not beconsidered as requirements of the standard.1.5 The terms
6、 used in this specification are identified inTerminologies C1180 and C1232.1.6 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.7 The fo
7、llowing safety hazards caveat pertains only to thetest methods section of this specification:This standard doesnot purport to address all of the safety concerns, if any,associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practicesa
8、nd determine the applicability of regulatory limitations priorto use.2. Referenced Documents2.1 ASTM Standards:2C5 Specification for Quicklime for Structural PurposesC91 Specification for Masonry CementC109/C109M Test Method for Compressive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm C
9、ubeSpecimens)C110 Test Methods for Physical Testing of Quicklime,Hydrated Lime, and LimestoneC128 Test Method for Density, Relative Density (SpecificGravity), and Absorption of Fine AggregateC144 Specification for Aggregate for Masonry MortarC150 Specification for Portland CementC188 Test Method for
10、 Density of Hydraulic CementC207 Specification for Hydrated Lime for Masonry Pur-posesC305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraul
11、ic Cements and ConcretesC595 Specification for Blended Hydraulic CementsC780 Test Method for Preconstruction and ConstructionEvaluation of Mortars for Plain and Reinforced UnitMasonryC952 Test Method for Bond Strength of Mortar to MasonryUnitsC979 Specification for Pigments for Integrally Colored Co
12、n-creteC1072 Test Methods for Measurement of Masonry FlexuralBond StrengthC1093 Practice for Accreditation of Testing Agencies forMasonryC1157 Performance Specification for Hydraulic CementC1180 Terminology of Mortar and Grout for Unit MasonryC1232 Terminology of MasonryC1324 Test Method for Examina
13、tion and Analysis of Hard-ened Masonry Mortar1This specification is under the jurisdiction of ASTM Committee C12 onMortars and Grouts for Unit Masonryand is the direct responsibility of Subcom-mittee C12.03 on Specifications for Mortars.Current edition approved June 1, 2012. Published July 2012. Ori
14、ginally approvedin 1951. Last previous edition approved in 2012 as C270 12. DOI: 10.1520/C0270-12A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Doc
15、ument Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1C1329 Specification for Mortar CementC1384 Specification for Admixtures for Masonry
16、 MortarsC1489 Specification for Lime Putty for Structural PurposesC1506 Test Method for Water Retention of HydraulicCement-Based Mortars and PlastersC1586 Guide for Quality Assurance of MortarsE72 Test Methods of Conducting Strength Tests of Panelsfor Building ConstructionE514 Test Method for Water
17、Penetration and LeakageThrough MasonryE518 Test Methods for Flexural Bond Strength of Masonry2.2 Masonry Industry Council:3Hot and Cold Weather Masonry Construction Manual, Janu-ary 19993. Specification Limitations3.1 Specification C270 is not a specification to determinemortar strengths through fie
18、ld testing.3.2 Laboratory testing of mortar to ensure compliance withthe property specification requirements of this specificationshall be performed in accordance with 5.3. The propertyspecification of this standard applies to mortar mixed to aspecific flow in the laboratory.3.3 The compressive stre
19、ngth values resulting from fieldtested mortars do not represent the compressive strength ofmortar as tested in the laboratory nor that of the mortar in thewall. Physical properties of field sampled mortar shall not beused to determine compliance to this specification and are notintended as criteria
20、to determine the acceptance or rejection ofthe mortar (see Section 8).4. Materials4.1 Materials used as ingredients in the mortar shall con-form to the requirements specified in 4.1.1 to 4.1.4.4.1.1 Cementitious MaterialsCementitious materials shallconform to the following ASTM specifications:4.1.1.
21、1 Portland CementTypes I, IA, II, IIA, III, IIIA, orV of Specification C150.4.1.1.2 Blended Hydraulic CementsTypes IS(70),IS(70)-A, IP, IP-A of Specification C595.4.1.1.3 Hydraulic CementsTypes GU, HE, MS, and HS ofSpecification C1157 (Types MH and LH are limited to use inthe property specifications
22、 only).4.1.1.4 Portland Blast-Furnace Slag Cement (for Use inProperty Specifications Only)Types IS($70) or IS($70)-Aof Specification C595.4.1.1.5 Masonry CementSee Specification C91.4.1.1.6 Mortar CementSee Specification C1329.4.1.1.7 QuicklimeSee Specification C5.4.1.1.8 Hydrated LimeSpecification
23、C207, Types S or SA.Types N or NA limes are permitted if shown by test orperformance record to be not detrimental to the soundness ofthe mortar.4.1.1.9 Lime PuttySee Specification C1489.4.1.2 AggregatesSee Specification C144.4.1.3 WaterWater shall be clean and free of amounts ofoils, acids, alkalies
24、, salts, organic materials, or other substancesthat are deleterious to mortar or any metal in the wall.4.1.4 AdmixturesAdmixtures shall not be added to mortarunless specified. Admixtures shall not add more than 65 ppm(0.0065 %) water soluble chloride or 90 ppm (0.0090 %) acidsoluble chloride to the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 1人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC2702012ASTANDARDSPECIFICATIONFORMORTARFORUNITMASONRY 砖块 工程 灰浆 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-466152.html