ASTM C210-1995(2014) Standard Test Method for Reheat Change of Insulating Firebrick《绝热耐火砖二次加热变化的标准试验方法》.pdf
《ASTM C210-1995(2014) Standard Test Method for Reheat Change of Insulating Firebrick《绝热耐火砖二次加热变化的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C210-1995(2014) Standard Test Method for Reheat Change of Insulating Firebrick《绝热耐火砖二次加热变化的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C210 95 (Reapproved 2014)Standard Test Method forReheat Change of Insulating Firebrick1This standard is issued under the fixed designation C210; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This test method covers the determination of
3、the perma-nent linear (and volume) change of insulating firebrick uponreheating under prescribed conditions.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesaf
4、ety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C24 Test Method for Pyrometric
5、Cone Equivalent (PCE) ofFireclay and High Alumina Refractory MaterialsC155 Classification of Insulating FirebrickE230 Specification and Temperature-Electromotive Force(EMF) Tables for Standardized ThermocouplesE1256 Test Methods for Radiation Thermometers (SingleWaveband Type)3. Significance and Use
6、3.1 Insulating firebrick (IFB) are classified by their bulkdensity and reheat change (see Classification C155). This testmethod defines thermal stability by measurement of IFBsreheat change following 24 h at a test temperature.3.2 Since this test exposes the entire sample to an isothermaltemperature
7、 condition, the user should be aware that mostapplications for IFB involve a thermal gradient which maycause the IFBs dimensions to change differentially.4. Apparatus4.1 The test kiln shall be capable of maintaining therequired temperature with a variation of not more than one halfa standard pyromet
8、ric cone over the hearth area during theprescribed heating schedule. If a gas- or oil-fired kiln is used,it shall be of the downdraft type and of such a design as not topermit the flame from the burner to impinge upon the testspecimens. The kiln atmosphere during the test shall be kept asoxidizing a
9、s is practicable.5. Procedure5.1 Test Specimens and Measurements:5.1.1 The test specimens shall consist of three brick (Note 1)measuring 9 by 412 by 212 or 3 in. (228 by 114 by 64 or 76mm) or three pieces of these dimensions cut out of largershapes.NOTE 1Three supporting brick from the same lot as t
10、he test specimensare required also, so that the test sample is comprised of six brick.5.1.2 Each specimen shall be labeled with ceramic paint,and before and after heating they shall be carefully measuredfor length (Note 2), width, and thickness. Three measurements(Note 3) to the nearest 0.02 in. (0.
11、5 mm) shall be taken for eachdimension and the average of these shall be used. Eachdimension shall be measured in three places along the longi-tudinal center line on opposite faces, one measurement at thecenter of the line and one12 in. (13 mm) in from each edge.Fig. 1 shows the location at which th
12、ese measurements are tobe made.NOTE 2For classifying IFB according to Classification C155, obtainthe reheat change from the 9-in. (228-mm) dimension measurements only.NOTE 3Because of the large pore size of some IFB, it is difficult tomeasure by means of calipers directly on the brick surfaces.Accur
13、acy maybe obtained by holding two small pieces of flat polished steel plate ofknown thickness against the faces between which the dimension is to beobtained, and calipering on the outside steel surfaces rather than directlyagainst the brick surfaces. It is permissible to use a measuring device toobt
14、ain the dimensions of the brick, provided the measurements are notaffected by large pores in the surface.5.2 Placing Test Specimens in Kiln:5.2.1 Place the test specimens in the kiln so that each willrest on a 9 by 212 or 3-in. (228 by 64 or 76-mm) face. Placeeach specimen upon the 9 by 212 or 3-in.
15、 face of a supportingbrick that shall be from the same lot as the test specimen. Place1This test method is under the jurisdiction of ASTM Committee C08 onRefractories and is the direct responsibility of Subcommittee C08.03 on PhysicalProperties.Current edition approved Sept. 1, 2014. Published Novem
16、ber 2014. Originallyapproved in 1946. Last previous edition approved in 2007 as C210 95 (2007)1.Originally part of C93. DOI: 10.1520/C0210-95R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards
17、volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1between the test specimen and the supporting member a layerof suitable refractory material, that is no
18、nreactive under the testconditions and passes an ASTM No. 16 (1.18-mm) sieve(equivalent to a 14-mesh Tyler Standard Series) and retainedon an ASTM No. 40 (425-m) sieve (equivalent to a 35-meshTyler Standard Series). Place each specimen no closer than 112in. (38 mm) from either the other test specime
19、ns or the furnacewall and parts.6. Temperature Measurement6.1 Measure the temperature within the kiln by means of anappropriate calibrated thermocouple. Refer to Table 1 andTable 2 of Standard E230 for the tolerances and upper tem-perature limits for use of various thermocouples. At highertemperatur
20、es, the thermocouple may be withdrawn and acalibrated optical or radiation pyrometer (refer to Test MethodE1256) can be used. Place the hot junction of the thermocoupleor sight the pyrometer so as to register the temperature of thetest specimens. Make temperature readings at intervals notgreater tha
21、n 15 min. Check the kiln periodically bythermocouples, pyrometers, or pyrometric cones (refer to TestMethod C24) to ensure that temperature over the hearth doesnot differ by more than 25F (14C) or one-half cone.7. Test Temperature Schedules and Duration of Test7.1 The temperature to be used for the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC21019952014STANDARDTESTMETHODFORREHEATCHANGEOFINSULATINGFIREBRICK 绝热 耐火砖 二次 加热 变化 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-466022.html