ASTM C204-2011 Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus《用透气性仪器测定硅水凝水泥细度的标准试验方法》.pdf
《ASTM C204-2011 Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus《用透气性仪器测定硅水凝水泥细度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C204-2011 Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus《用透气性仪器测定硅水凝水泥细度的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C204 11American Association StateHighway and Transportation Officials StandardAASHTO No.: T 153Standard Test Methods forFineness of Hydraulic Cement by Air-PermeabilityApparatus1This standard is issued under the fixed designation C204; the number immediately following the designation in
2、dicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers determination o
3、f the fineness ofhydraulic cement, using the Blaine air-permeability apparatus,in terms of the specific surface expressed as total surface areain square centimetres per gram, or square metres per kilogram,of cement. Two test methods are given: Test Method A is theReference Test Method using the manu
4、ally operated standardBlaine apparatus, while Test Method B permits the use ofautomated apparatus that has in accordance with the qualifica-tion requirements of this test method demonstrated acceptableperformance. Although the test method may be, and has been,used for the determination of the measur
5、es of fineness ofvarious other materials, it should be understood that, ingeneral, relative rather than absolute fineness values areobtained.1.1.1 This test method is known to work well for portlandcements. However, the user should exercise judgement indetermining its suitability with regard to fine
6、ness measure-ments of cements with densities, or porosities that differ fromthose assigned to Standard Reference Material No. 114.1.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its u
7、se. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A582/A582M Specification for Free-Machining StainlessSteel BarsC670 Practi
8、ce for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsE832 Specification for Laboratory Filter Papers2.2 Other Document:No. 114 National Institute of Standards and TechnologyStandard Reference Material3BS 4359: 1971 British Standard Method for the Determina-tion of
9、 Specific Surface of Powders: Part 2: Air Perme-ability Methods4TEST METHOD A: REFERENCE METHOD3. Apparatus3.1 Nature of ApparatusThe Blaine air-permeability ap-paratus consists essentially of a means of drawing a definitequantity of air through a prepared bed of cement of definiteporosity. The numb
10、er and size of the pores in a prepared bed ofdefinite porosity is a function of the size of the particles anddetermines the rate of airflow through the bed. The apparatus,illustrated in Fig. 1, shall consist specifically of the partsdescribed in 3.2-3.8.3.2 Permeability CellThe permeability cell sha
11、ll consistof a rigid cylinder 12.70 6 0.10 mm in inside diameter,constructed of austenitic stainless steel. The interior of the cellshall have a finish of 0.81 m (32 in.). The top of the cell shallbe at right angles to the principal axis of the cell. The lowerportion of the cell must be able to form
12、 an airtight fit with theupper end of the manometer, so that there is no air leakagebetween the contacting surfaces. A ledge12 to 1 mm in widthshall be an integral part of the cell or be firmly fixed in the cell55 6 10 mm from the top of the cell for support of theperforated metal disk. The top of t
13、he permeability cell shall befitted with a protruding collar to facilitate the removal of thecell from the manometer.NOTE 1Specification A582/A582M Type 303 stainless steel (UNSdesignation S30300) has been found to be suitable for the construction ofthe permeability cell and the plunger.3.3 DiskThe
14、disk shall be constructed of noncorrodingmetal and shall be 0.9 6 0.1 mm in thickness, perforated with30 to 40 holes 1 mm in diameter equally distributed over its1This test method is under the jurisdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.25 on Fine
15、ness.Current edition approved June 1, 2011. Published August 2011. Originallyapproved in 1946. Last previous edition approved in 2007 as C204 07. DOI:10.1520/C0204-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual
16、Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.4Available from British Standards Institute (BSI)
17、, 389 Chiswick High Rd.,London W4 4AL, U.K., http:/www.bsi-.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.area. The disk shall fit the inside of the cell snugly. The
18、 centerportion of one side of the disk shall be marked or inscribed ina legible manner so as to permit the operator always to placethat side downwards when inserting it into the cell. Themarking or inscription shall not extend into any of the holes,nor touch their peripheries, nor extend into that a
19、rea of the diskthat rests on the cell ledge.3.4 PlungerThe plunger shall be constructed of austeniticstainless steel and shall fit into the cell with a clearance of notmore than 0.1 mm. The bottom of the plunger shall sharplymeet the lateral surfaces and shall be at right angles to theprincipal axis
20、. An air vent shall be provided by means of a flat3.0 6 0.3 mm wide on one side of the plunger. The top of theplunger shall be provided with a collar such that when theplunger is placed in the cell and the collar brought in contactwith the top of the cell, the distance between the bottom of theplung
21、er and the top of the perforated disk shall be 15 6 1 mm.3.5 Filter PaperThe filter paper shall be medium reten-tive, corresponding to Type 1, Grade B, in accordance withSpecification E832. The filter paper disks shall be circular, withsmooth edges, and shall have the same diameter (Note 2)astheinsi
22、de of the cell.NOTE 2Filter paper disks that are too small may leave part of thesample adhering to the inner wall of the cell above the top disk. When toolarge in diameter, the disks have a tendency to buckle and cause erraticresults.3.6 ManometerThe U-tube manometer shall be con-structed according
23、to the design indicated in Fig. 1, usingnominal 9-mm outside diameter, standard-wall, glass tubing.The top of one arm of the manometer shall form an airtightconnection with the permeability cell. The manometer armconnected to the permeability cell shall have a midpoint lineetched around the tube at
24、125 to 145 mm below the top sideFIG. 1 Blaine Air-Permeability ApparatusC204 112outlet and also others at distances of 15 6 1 mm, 70 6 1 mm,and 110 6 1 mm above that line.Aside outlet shall be providedat 250 to 305 mm above the bottom of the manometer for usein the evacuation of the manometer arm co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC2042011STANDARDTESTMETHODSFORFINENESSOFHYDRAULICCEMENTBYAIRPERMEABILITYAPPARATUS 透气性 仪器 测定 硅水凝 水泥

链接地址:http://www.mydoc123.com/p-466002.html