ASTM C187-2016 Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste《水凝水泥浆正常稠度所需水量的标准试验方法》.pdf
《ASTM C187-2016 Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste《水凝水泥浆正常稠度所需水量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C187-2016 Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste《水凝水泥浆正常稠度所需水量的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C187 111C187 16 American Association StateHighway and Transportation Officials StandardAASHTO No.: T 129Standard Test Method forAmount of Water Required for Normal Consistency ofHydraulic Cement Paste1This standard is issued under the fixed designation C187; the number immediately follo
2、wing the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTESection 8.1 was revised
3、 editorially in October 2011 to fix a typographical error.1. Scope*1.1 This test method covers the determination of the normal consistency of hydraulic cement.1.2 UnitsThe values stated in SI units are to be regarded as standard. No other units of measurement are included in thisstandard.1.3 This st
4、andard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. See 1.4 for a specific warn
5、ing statement.1.4 WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue uponprolonged exposure. The use of gloves, protective clothing, and eye protection is recommended. Wash contact area with copiousamounts of water after contact. Wash eyes for a
6、minimum of 15 min. Avoid exposure of the body to clothing saturated with theliquid phase of the unhardened material. Remove contaminated clothing immediately after exposure.22. Referenced Documents2.1 ASTM Standards:3C219 Terminology Relating to Hydraulic CementC305 Practice for Mechanical Mixing of
7、 Hydraulic Cement Pastes and Mortars of Plastic ConsistencyC511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of HydraulicCements and ConcretesC1005 Specification for Reference Masses and Devices for Determining Mass and Volume for Use in th
8、e Physical Testing ofHydraulic CementsD1193 Specification for Reagent WaterE177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods3. Terminology3.1 Normal consistency is defined in Terminology standard C219.4. Significance and Use4.1 This test method is intended to be used to dete
9、rmine the amount of water required to prepare hydraulic cement pastes withnormal consistency, as required for certain standard tests.5. Apparatus5.1 Reference Masses and Devices for Determining Mass, conforming to the requirements of Specification C1005. The devicesfor determining mass shall be eval
10、uated for precision and bias at a total load of 1000 g.1 This test method is under the jurisdiction of ASTM Committee C01 on Cement and is the direct responsibility of Subcommittee C01.22 on Workability.Current edition approved April 1, 2011Dec. 1, 2016. Published May 2011December 2016. Originally a
11、pproved in 1944. Last previous edition approved in 20102011 asC187C187 11110 DOI: 10.1520/C0187-11.10.1520/C0187-16.2 Section on Safety, Manual of Cement Testing, Annual Book of ASTM Standards, Vol 04.01.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Ser
12、vice at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previo
13、us version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Chang
14、es section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2 Glass Graduates, 200 or 250-mL capacity, and conforming to the requirements of Specification C1005.5.3 Vicat ApparatusThe Vicat apparatu
15、s shall consist of a frame A (Fig. 1) bearing a movable rod B, weighing 300 g, one endC, the plunger end, being 10 mm in diameter for a distance of at least 50 mm, and the other end having a removable needle D,1 mm in diameter and 50 mm in length. The rod B is reversible, and can be held in any desi
16、red position by a set screw E, andhas an adjustable indicator F, which moves over a scale (graduated in millimetres) attached to the frame A. The paste is held ina rigid conical ring G, resting on a plane nonabsorptive square base plate H, about 100 mm on each side. The rod B shall be madeof stainle
17、ss steel having a hardness of not less than 35 HRC (See Note 1), and shall be straight with the plunger end which isperpendicular to the rod axis. The ring shall be made of a noncorroding, nonabsorbent material, and shall have an inside diameterof 70 mm at the base and 60 mm at the top, and a height
18、 of 40 mm. In addition to the above, the Vicat apparatus shall conformto the following requirements:Weight of movable rod 300 0.5 gDiameter of plunger end of rod 10 0.05 mmDiameter of needle 1 0.05 mmInside diameter of ring at bottom 70 3 mmInside diameter of ring at top 60 3 mmHeight of ring 40 1 m
19、mGraduated scale The graduated scale, when comparedwith a standard scale accurate to within0.1 mm at all points, shall not show adeviation at any point greater than 0.25mm.NOTE 1The requirement that the rod be made of stainless steel shall apply only to new Vicat apparatus or replacement rods and no
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1872016STANDARDTESTMETHODFORAMOUNTOFWATERREQUIREDFORNORMALCONSISTENCYOFHYDRAULICCEMENTPASTE 水泥浆

链接地址:http://www.mydoc123.com/p-465947.html