ASTM C187-2010 Standard Test Method for Normal Consistency of Hydraulic Cement《水硬水泥正常稠度的标准试验方法》.pdf
《ASTM C187-2010 Standard Test Method for Normal Consistency of Hydraulic Cement《水硬水泥正常稠度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C187-2010 Standard Test Method for Normal Consistency of Hydraulic Cement《水硬水泥正常稠度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C187 10American Association StateHighway and Transportation Officials StandardAASHTO No.: T 129Standard Test Method forNormal Consistency of Hydraulic Cement1This standard is issued under the fixed designation C187; the number immediately following the designation indicates the year ofo
2、riginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the normalcons
3、istency of hydraulic cement.1.2 UnitsThe values stated in SI units are to be regardedas standard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user o
4、f this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See 1.4 for aspecific warning statement.1.4 WarningFresh hydraulic cementitious mixtures arecaustic and may cause chemical burns to skin and tissue uponprolo
5、nged exposure. The use of gloves, protective clothing,and eye protection is recommended. Wash contact area withcopious amounts of water after contact. Wash eyes for aminimum of 15 min. Avoid exposure of the body to clothingsaturated with the liquid phase of the unhardened material.Remove contaminate
6、d clothing immediately after exposure.22. Referenced Documents2.1 ASTM Standards:3C305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC490 Practice for Use of Apparatus for the Determinationof Length Change of Hardened Cement Paste, Mortar, andConcreteC511
7、 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and ConcretesC1005 Specification for Reference Masses and Devices forDetermining Mass and Volume for Use in the PhysicalTesting of Hydraulic CementsD1193 Specification for Rea
8、gent WaterE177 Practice for Use of the Terms Precision and Bias inASTM Test Methods3. Significance and Use3.1 This test method is intended to be used to determine theamount of water required to prepare hydraulic cement pastesfor testing.4. Apparatus4.1 Reference Masses and Devices for Determining Ma
9、ss,conforming to the requirements of Specification C1005. Thedevices for determining mass shall be evaluated for precisionand bias at a total load of 1000 g.4.2 Glass Graduates, 200 or 250-mLcapacity, and conform-ing to the requirements of Practice C490.4.3 Vicat ApparatusThe Vicat apparatus shall c
10、onsist of aframe A (Fig. 1) bearing a movable rod B, weighing 300 g, oneend C, the plunger end, being 10 mm in diameter for a distanceof at least 50 mm, and the other end having a removable needleD, 1 mm in diameter and 50 mm in length. The rod B isreversible, and can be held in any desired position
11、 by a setscrew E, and has an adjustable indicator F, which moves overa scale (graduated in millimetres) attached to the frame A. Thepaste is held in a rigid conical ring G, resting on a planenonabsorptive square base plate H, about 100 mm on each side.The rod B shall be made of stainless steel havin
12、g a hardness ofnot less than 35 HRC (See Note 1), and shall be straight withthe plunger end which is perpendicular to the rod axis. The ringshall be made of a noncorroding, nonabsorbent material, andshall have an inside diameter of 70 mm at the base and 60 mmat the top, and a height of 40 mm. In add
13、ition to the above, theVicat apparatus shall conform to the following requirements:Weight of movable rod 300 6 0.5 gDiameter of plunger end of rod 10 6 0.05 mmDiameter of needle 1 6 0.05 mmInside diameter of ring at bottom 70 6 3mmInside diameter of ring at top 60 6 3mmHeight of ring 40 6 1mmGraduat
14、ed scale The graduated scale, when comparedwith a standard scale accurate to within0.1 mm at all points, shall not show adeviation at any point greater than 0.25mm.1This test method is under the jurisdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.22 on Wo
15、rkability.Current edition approved May 1, 2010. Published June 2010. Originallyapproved in 1944. Last previous edition approved in 2004 as C18704. DOI:10.1520/C0187-10.2Section on Safety, Manual of Cement Testing, Annual Book of ASTMStandards, Vol 04.01.3For referenced ASTM standards, visit the ASTM
16、 website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr H
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1872010STANDARDTESTMETHODFORNORMALCONSISTENCYOFHYDRAULICCEMENT 水泥 正常 稠度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-465944.html