《ASTM C1815-2017 Standard Practice for Periodically Measuring and Monitoring Sealant Dimensions to Stability Following a Period of Compression or Tension《在压缩或张力期间定期测量和监测密封剂尺寸对稳定性的标准.pdf》由会员分享,可在线阅读,更多相关《ASTM C1815-2017 Standard Practice for Periodically Measuring and Monitoring Sealant Dimensions to Stability Following a Period of Compression or Tension《在压缩或张力期间定期测量和监测密封剂尺寸对稳定性的标准.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1815 17Standard Practice forPeriodically Measuring and Monitoring Sealant Dimensionsto Stability Following a Period of Compression or Tension1This standard is issued under the fixed designation C1815; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a procedure for measuring andmonitoring the physical
3、dimensions of an elastomeric jointsealant in a test specimen configuration described in TestMethod C719 following a period of compression or tension.These sealant materials are typically highly filled elasticmaterials. The dimensional change of these sealant materials isdetermined by measuring the d
4、imensions at specific intervalsover a period of time.1.2 The values stated in SI units are to be regarded asstandard. The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility o
5、f the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization establ
6、ished in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:C717 Terminology of Building Seals and SealantsC719 Test Method f
7、or Adhesion and Cohesion of Elasto-meric Joint Sealants Under Cyclic Movement (HockmanCycle)C1589 Practice for Outdoor Weathering of ConstructionSeals and SealantsC1735 Test Method for Measuring the Time DependentModulus of Sealants Using Stress RelaxationE631 Terminology of Building Constructions3.
8、 Terminology3.1 Definitions:3.1.1 For definitions of terms used in this practice, refer toTerminologies E631 and C717.4. Summary of Practice4.1 This practice consists of monitoring the dimensionalchange of a sealant for a period of time required to establishdimensional stability.4.2 The motivation f
9、or this practice is to monitor thedimensions of a sealant at any time, but especially after aperiod of extended tension or compression to establish thestable dimensions of that sealant. The latter is used in appli-cation of a standard, such as Test Method C1735, by using theaccurate dimensions deter
10、mined by this practice after dimen-sional stability is attained.4.3 This practice will enable determination of the stabledimensions of a sealant. It will also allow the reporting of thetime scale over which the sealant dimensions are changing.5. Significance and Use5.1 Many sealants have been observ
11、ed to dimensionallychange following a period of compression or tension, such asoccurs during exposure in accordance with Practice C1589.Ithas been shown that for some sealants, increasing exposure toweathering increases the time required for dimensional stabil-ity and decreases the magnitude of dime
12、nsional change.Dimensional stability and knowledge of the stable sealantdimensions are critical to the accurate measurement of thesealants modulus by a test such as Test Method C1735.5.2 This practice will find application in improving theaccuracy of the modulus determined by a standard such as Test
13、Method C1735 by using the accurate dimensions determinedby this practice after stability is attained.6. Apparatus6.1 Dimensional Measuring ToolA micrometer, such asdigital calipers, capable of measuring the dimensions ofaluminum substrate and sealant to an accuracy of at least60.05 mm (60.002 in.),
14、is required. An accurate measurementof the geometry is critical. For example, for a 12.5 mm thicksealant that will experience a 15 % strain when tested inaccordance with Test Method C1735, the total deflection is1This practice is under the jurisdiction of ASTM Committee C24 on BuildingSeals and Seal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC18152017STANDARDPRACTICEFORPERIODICALLYMEASURINGANDMONITORINGSEALANTDIMENSIONSTOSTABILITYFOLLOWINGAPERIODOFCOMPRESSIONORTENSION

链接地址:http://www.mydoc123.com/p-465877.html