ASTM C181-2011(2018) Standard Test Method for Workability Index of Fireclay and High-Alumina Refractory Plastics.pdf
《ASTM C181-2011(2018) Standard Test Method for Workability Index of Fireclay and High-Alumina Refractory Plastics.pdf》由会员分享,可在线阅读,更多相关《ASTM C181-2011(2018) Standard Test Method for Workability Index of Fireclay and High-Alumina Refractory Plastics.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C181 11 (Reapproved 2018)Standard Test Method forWorkability Index of Fireclay and High-Alumina RefractoryPlastics1This standard is issued under the fixed designation C181; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the work-ability index of fireclay and high-alumina refrac
3、tory plastics bymeasuring the plastic deformation of a molded test specimenwhen subjected to impacts.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not cons
4、idered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitati
5、ons prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization Tec
6、hnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D2906 Practice for Statements on Precision and Bias forTextiles (Withdrawn 2008)33. Significance and Use3.1 Workability index serves as a measure of the facilitywith which refractory plastic materials can be rammed,gu
7、nned, or vibrated into place.3.2 Workability index is commonly used to control consis-tency of plastics during manufacture. It has also been founduseful for specification acceptance by the consumer.3.3 The workability index determination can provide infor-mation for developing a plastic body. When a
8、 sample splitsunder impact at various water contents, it is an indication thatthe material is “short” or lacking in plasticity.3.4 Determinations on samples that split during impact willbe difficult to reproduce. If the sample splits, the measurementis not a true indication of deformation. This shou
9、ld be noted inthe report.4. Apparatus4.1 RammerThe apparatus shall consist of the deviceknown as the sand rammer for refractories (see Fig. 1). It shallconsist essentially of a steel cylindrical mold (specimen tube)2.00 in. (50.8 mm) in inside diameter and 4.75 in. (120.6 mm)in length, supported in
10、a vertical position on the same axis asa shaft to which shall be fastened a plunger that fits inside themold. A 14-lb (6.4-kg) cylindrical weight slides on the sameshaft and is arranged to fall a distance of 2 in. (51 mm) beforeengaging a collar fastened to the shaft. As shown in Fig. 1, theweight m
11、ay be raised by a manually rotated cam. Provisionshall be made by the equipment manufacturer to support theweight, thereby removing the load from the vertical shaft(example shown in Fig. 2). The sand rammer will include alinear scale capable of measuring sample height to 0.02 in.(0.5 mm) with a typi
12、cal range of 1.7 to 2.5 in. (Note 1). Theportion of the scale to be used shall be adjusted so that whenthe vertical shaft is measuring a 3.00-in. standard, 3.00 in. isread on the scale.NOTE 1The apparatus as described in this section is capable ofmeasuring workabilities up to about 32 %. For product
13、s of higherworkability, a suitable spacer block may be installed under the specimen.4.1.1 Mounting for RammerIt is recommended the ram-mer be mounted on sand rammer base sold by the manufactureror a concrete column to isolate the rammer from vibrationvariations. The rammer is to be secured onto the
14、base orcolumn using steel bolts. Variable results are obtained from thetest unless the described mounting or an acceptable alternativemounting is used for the rammer. An acceptable mounting1This test method is under the jurisdiction of ASTM Committee C08 onRefractories and is the direct responsibili
15、ty of Subcommittee C08.09 on Monolith-ics.Current edition approved Oct. 1, 2018. Published October 2018. Originallyapproved in 1943. Last previous edition approved in 2011 as C181 11. DOI:10.1520/C0181-11R18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custome
16、r Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, Wes
17、t Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Tr
18、ade Organization Technical Barriers to Trade (TBT) Committee.1method is one that can be calibrated using the manufacturerscalibration rings described below in 4.1.2.4.1.2 Maintenance and CalibrationAs needed, dependingon use, clean all moving parts and lubricate with SAE 10 oil.Make periodic checks
19、of the height that the weight drops toensure the weight is being raised 2 in. (51 mm). Inspect therammer to determine whether it and the foundation areproducing full ramming energy. This is accomplished by usingcalibrated impact rings.4Inspect the specimen tube (Note 2).NOTE 2Variation in the smooth
20、ness and dimensions of the specimentube may cause variation in workability values. For referee testing, thespecimen tube may require periodic comparison with a master precisionspecimen tube sold by manufacturer.5. Test Specimens5.1 Temperature of Refractory PlasticSince the workabil-ity index may va
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC18120112018STANDARDTESTMETHODFORWORKABILITYINDEXOFFIRECLAYANDHIGHALUMINAREFRACTORYPLASTICSPDF

链接地址:http://www.mydoc123.com/p-465873.html