ASTM C1744-2012 Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Commercial Industrial Building Construction《商业 工业建筑物用辐射屏蔽系统(RBS)的安装和使用的标准实施规程》.pdf
《ASTM C1744-2012 Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Commercial Industrial Building Construction《商业 工业建筑物用辐射屏蔽系统(RBS)的安装和使用的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1744-2012 Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Commercial Industrial Building Construction《商业 工业建筑物用辐射屏蔽系统(RBS)的安装和使用的标准实施规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1744 12Standard Practice forInstallation and Use of Radiant Barrier Systems (RBS) inCommercial/Industrial Building Construction1This standard is issued under the fixed designation C1744; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice has been prepared for use by the designer,specifier, builder, and the inst
3、aller of radiant barrier systems(RBS) for use in commercial/industrial building constructionnot otherwise restricted from use. The scope is limited toinstruction relative to the use and installation of RBS, includ-ing a surface(s) normally having an emittance of 0.1 or less,such as metallic foil or
4、metallic foil deposits, mounted onsubstrates. Some examples that this practice is intended toaddress include: (1) low-emittance surfaces in vented buildingenvelope cavities intended to retard radiant transfer across theairspace: (2) low-emittance surfaces at interior building sur-faces intended to r
5、etard radiant transfer to, or from, buildinginhabitants; and (3) low-emittance surface at interior buildingsurfaces intended to reduce radiant transfer to, or from, radiantheating or cooling systems.1.2 This practice covers the installation process from pre-installation inspection through the post-i
6、nstallation procedure.It does not cover the production of the radiant barrier materials.(See Specification C1313.)1.3 This practice is not intended to replace the manufactur-ers installation instructions but shall be used in conjunctionwith such instructions. This practice is not intended to super-c
7、ede local, state, federal, or international codes.1.4 This practice assumes that the installer possesses a goodworking knowledge of the applicable codes and regulations,safety practices, tools, equipment, and methods necessary forinstallation of radiant barrier materials. It also assumes that theins
8、taller understands the fundamentals of commercial/industrial building construction that affect the installation ofRBS.1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onl
9、yand are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitat
10、ions prior to use. For specificprecautionary statements see Sections 5 and 7.1.6.1 When the installation or use of radiant barrier mate-rials, accessories, and systems has the potential to pose safetyor health problems, the manufacturer shall provide the userappropriate current information regarding
11、 any known prob-lems associated with the use of the product of the company andshall also specify protective measures.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC1313 Specification for Sheet Radiant Barriers for BuildingConstruction Applications2.2 NFPA
12、Standards:3NFPA 54 National Fuel Gas CodeNFPA 211 Standard for Chimneys, Fireplaces and Vents2.3 Other Document:4CPSC Product Safety Fact Sheet No. 18 “The Home Elec-trical System”3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, refer to Terminology C168.3.2 Definitions
13、of Terms Specific to This Standard:3.2.1 applicator, nperson or persons who apply radiantbarrier materials in buildings.3.2.2 conditioned space, nany space in a building that isserved by a heating or cooling system.3.2.3 girts, ntypically, 1 or 23 nominal lumber, installedover rafters or trusses, to
14、 be used for securing both the RBSand metal decking, which is used on wall assemblies forsecuring metal siding.1This practice is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.21 on ReflectiveInsulation.Current edition approved
15、May 1, 2012. Published May 2012. Originallyapproved in 2010. Last previous edition approved in 2010 as C174410. DOI:10.1520/C174412.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume inform
16、ation, refer to the standards Document Summary page onthe ASTM website.3Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/www.nfpa.org.4Available from U.S. Consumer Product Safety Commission (CPSC), 4330 EastWest Hwy., Bethesda, MD 20814, ht
17、tp:/www.cpsc.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.4 open air space, nvented building cavity (for ex-ample, an open-ended wall or ceiling assembly) or a largeconditioned or unconditioned building space.3.2.4.1 Discu
18、ssionA large building space is defined asone whose minimum dimension exceeds 2 ft (0.6 m).3.2.5 purlins, nsteel or wood structural members that areused to support the buildings primary structural load above thefloor.3.2.6 radiant barrier system, RBS, nbuilding constructionassembly consisting of a lo
19、wemittance (0.1 or less) surfacebounded by an open air space on one or both sides.3.2.6.1 DiscussionDiscussionAn RBS is used for thesole purpose of limiting heat transfer by radiation into or out ofa building assembly. An RBS is not specifically intended toreduce heat transfer by convection or condu
20、ction.3.2.7 subpurlins, nsecondary steel or wood structuralmembers that are used primarily to support the roofing andsiding of a building are often identified as “Z purlins,” “Cchannel,” “I beams,” or other structural configurations basedon cross-sectional appearance.3.2.8 thermal break, nlow therma
21、l conductivity productsuch as wood or polystyrene used to separate two higherconductivity products that are most often metal in an effort toreduce heat gain or loss and prevent the potential for conden-sation problems.4. Significance and Use4.1 In this practice it is recognized that effectiveness, s
22、afety,and durability of an RBS depends not only on the quality of thematerials, but also on proper installation.4.2 Improper installation of an RBS will reduce the thermaleffectiveness, cause fire risks and other unsafe conditions, andpromote deterioration of the structure in which it is installed.I
23、mproper installations include fires caused by: (1) heat buildupin recessed lighting fixtures, (2) deterioration or failure ofelectrical wiring components, and (3) deterioration in woodstructures and paint failure as a result of moisture accumula-tion.4.3 This practice provides direction for the inst
24、allation ofRBS products in a safe and effective manner.Actual conditionsin existing buildings vary greatly and care shall be taken toensure safe and effective installation.4.4 In this practice, requirements are presented that are bothgeneral and specific in nature and practical. They are notintended
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17442012STANDARDPRACTICEFORINSTALLATIONANDUSEOFRADIANTBARRIERSYSTEMSRBSINCOMMERCIALINDUSTRIALBUILDINGCONSTRUCTION

链接地址:http://www.mydoc123.com/p-465730.html