ASTM C1743-2012 Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Residential Building Construction《住宅建筑物构造用辐射屏蔽系统(RBS)的使用和安装的标准实施规程》.pdf
《ASTM C1743-2012 Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Residential Building Construction《住宅建筑物构造用辐射屏蔽系统(RBS)的使用和安装的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1743-2012 Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Residential Building Construction《住宅建筑物构造用辐射屏蔽系统(RBS)的使用和安装的标准实施规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1743 12Standard Practice forInstallation and Use of Radiant Barrier Systems (RBS) inResidential Building Construction1This standard is issued under the fixed designation C1743; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice has been prepared for use by the designer,specifier, builder, and the installer of r
3、adiant barrier systems(RBS) for use in (multi- and single-family) residential buildingconstruction, not otherwise restricted from use. The scope islimited to instructions relative to the use and installation ofRBS, including a surface(s) normally having an emittance of0.1 or less, such as metallic f
4、oil or metallic foil deposits,mounted on substrates. Some examples that this practice isintended to address include: (1) low-emittance surfaces invented building envelope cavities intended to retard radianttransfer across the airspace: (2) low-emittance surfaces atinterior building surfaces intended
5、 to retard radiant transfer to,or from, building inhabitants; and (3) low-emittance surface atinterior building surfaces intended to reduce radiant transfer to,or from, radiant heating or cooling systems.1.2 This practice covers the installation process from pre-installation inspection through the p
6、ost-installation procedure.It does not cover the production of the radiant barrier materials.(See Specification C1313.)1.3 This practice is not intended to replace the manufactur-ers installation instructions but shall be used in conjunctionwith such instructions. This practice is not intended to su
7、per-cede local, state, federal, or international codes.1.4 This practice assumes that the installer possesses a goodworking knowledge of the applicable codes and regulations,safety practices, tools, equipment, and methods necessary forinstallation of radiant barrier materials. It also assumes that t
8、heinstaller understands the fundamentals of residential buildingconstruction that affect the installation of RBS.1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand
9、are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations
10、prior to use. For specificprecautionary statements see Sections 5 and 7.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC1313 Specification for Sheet Radiant Barriers for BuildingConstruction Applications2.2 NFPA Standards3NFPA 54 National Fuel Gas CodeNFPA
11、211 Standard for Chimneys, Fireplaces and Vents2.3 Other Document:4CPSC Product Safety Fact Sheet No. 18 “The Home Elec-trical System”3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, refer to Terminology C168.3.2 Definitions of Terms Specific to This Standard:3.2.1 appli
12、cator, nperson or persons who apply radiantbarrier materials in buildings.3.2.2 conditioned space, nany space in a building that isserved by a heating or cooling system.3.2.3 open air space, nvented building cavity (for ex-ample, a vented attic) or a large conditioned or unconditionedbuilding space.
13、3.2.3.1 DiscussionA large building space is defined asone whose minimum dimension exceeds 2 ft (0.6 m).3.2.4 radiant barrier system, RBS, nbuilding constructionassembly consisting of a low-emittance (0.1 or less) surfacebounded by an open air space on one or both sides.3.2.4.1 DiscussionA RBS is use
14、d for the sole purpose oflimiting heat transfer by radiation, into or out of a building1This practice is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.21 on ReflectiveInsulation.Current edition approved May 1, 2012. Published J
15、une 2012. originally approvedin 2010. Last previous edition approved in 2010 as C174310. DOI: 10.1520/C174312.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the st
16、andards Document Summary page onthe ASTM website.3Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/www.nfpa.org.4Available from U.S. Consumer Product Safety Commission (CPSC), 4330 EastWest Hwy., Bethesda, MD 20814, http:/www.cpsc.gov.1Copy
17、right ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.assembly. An RBS is not specifically intended to reduce heattransfer by convection or conduction.4. Significance and Use4.1 In this practice it is recognized that effectiveness, safety,and d
18、urability of an RBS depends not only on the quality of thematerials, but also on proper installation.4.2 Improper installation of an RBS will reduce the thermaleffectiveness, cause fire risks and other unsafe conditions, andpromote deterioration of the structure in which it is installed.Improper ins
19、tallations include fires caused by: (1) heat buildupin recessed lighting fixtures, (2) deterioration or failure ofelectrical wiring components, and (3) deterioration in woodstructures and paint failure as a result of moisture accumula-tion.4.3 This practice provides directions for the installation o
20、fRBS products in a safe and effective manner. Actual conditionsin existing buildings vary greatly and care shall be taken toensure safe and effective installation.4.4 In this practice requirements are presented that are bothgeneral and specific in nature and practical. They are notintended as specif
21、ic instructions unless so indicated. The usershall consult the manufacturer for recommended applicationand installation methods. The requirements in this practiceshall be the minimum material and installation requirementsfor RBS.5. Safety Precautions5.1 The applicator shall wear proper clothing and
22、equipmentas specified by the manufacturer and shall follow all local,state, and federal codes and safety regulations for buildingconstruction sites, for example hard hats, safety gogglesrespiratory protection, and other safety items.6. Pre-Installation Inspection and Preparation6.1 Pre-Installation
23、Inspections: New and Retrofit Build-ings:6.1.1 Inspect the roof, wall, ceiling, and floor buildingmaterials to identify areas in which previous or existingmoisture problems have caused paint peeling, lumber warpage,staining, visible fungal growth, rotting, or other structuraldamage. Do not install t
24、he RBS in such areas until theowner/builder has been informed and has certified that theseconditions have been corrected and the cause of the conditionrepaired.6.1.2 In areas where an RBS is to be installed, componentsof the electrical system shall be in good condition. When thereis reason to believ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17432012STANDARDPRACTICEFORINSTALLATIONANDUSEOFRADIANTBARRIERSYSTEMSRBSINRESIDENTIALBUILDINGCONSTRUCTION

链接地址:http://www.mydoc123.com/p-465728.html