《ASTM C1740-2016 Standard Practice for Evaluating the Condition of Concrete Plates Using the Impulse-Response Method《用脉冲响应法评定混凝土板状况的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1740-2016 Standard Practice for Evaluating the Condition of Concrete Plates Using the Impulse-Response Method《用脉冲响应法评定混凝土板状况的标准实施规程》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1740 16Standard Practice forEvaluating the Condition of Concrete Plates Using theImpulse-Response Method1This standard is issued under the fixed designation C1740; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice provides the procedure for using theimpulse-response method to evaluate rapidly the condition of
3、concrete slabs, pavements, bridge decks, walls, or other plate-like structures.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with
4、its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 The text of this standard references notes and footnotesthat provide explanatory material. These notes and f
5、ootnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.2. Referenced Documents2.1 ASTM Standards:2C125 Terminology Relating to Concrete and Concrete Ag-gregatesC1383 Test Method for Measuring the P-Wave Speed andthe Thickness of Concrete Plates Using t
6、he Impact-EchoMethodD5882 Test Method for Low Strain Impact Integrity Testingof Deep FoundationsE1316 Terminology for Nondestructive Examinations3. Terminology3.1 Definitions:3.1.1 Refer to Terminology C125 for general terms relatedto concrete. Refer to Terminology E1316 for terms related tonondestr
7、uctive ultrasonic examination that are applicable tothis practice.3.2 Definitions of Terms Specific to This Standard:3.2.1 impulse-response method, na nondestructive testmethod based on the use of mechanical impact to causetransient vibration of a concrete test element, the use of abroadband velocit
8、y transducer placed on the test elementadjacent to the impact point to measure the response, and theuse of signal processing to obtain the mobility spectrum of thetest element.3.2.1.1 DiscussionFig. 1 shows the testing configurationfor the impulse-response method. The hammer contains a loadcell to m
9、easure the transient impact force and a velocitytransducer is used to measure the resulting motion of the testobject (see top plots in Fig. 2). In plate-like structures, theimpact results predominantly in flexural vibration of the testedelement, although other modes can be excited. Waveformsfrom the
10、 load cell and velocity transducer are converted to thefrequency domain and used to calculate the mobility spectrum,which is analyzed to obtain parameters representing the el-ements response to the impact. These parameters are used toidentify anomalous regions within the tested element.3.2.2 mobilit
11、y, nratio of the velocity amplitude at the testpoint to the force amplitude at a given frequency, expressed inunits of (m/s)/N.3.2.2.1 DiscussionFor a plate-like structure, mobility is anindicator of the relative flexibility of the tested element, whichis a function of plate thickness, concrete elas
12、tic modulus,support conditions, and presence of internal defects. A highermobility indicates that the element is relatively more flexible atthat test point (1,2).33.2.3 mobility ratio, peak-mean, nthe ratio of the peakmobility value between 0 to 100 Hz to the average mobilitybetween 100 to 800 Hz3.2
13、.3.1 DiscussionA high ratio of the peak mobility to theaverage mobility has been found to correlate with poor support1This practice is under the jurisdiction of ASTM Committee C09 on Concreteand ConcreteAggregates and is the direct responsibility of Subcommittee C09.64 onNondestructive and In-Place
14、Testing.Current edition approved Dec. 15, 2016. Published January 2017. Originallyapproved in 2010. Last previous edition approved in 2010 as C174010. DOI:10.1520/C1740-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
15、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The boldface numbers in parentheses refer to a list of references at the end ofthis standard.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,
16、100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and
17、 Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1conditions or voids that may exist beneath concrete slabsbearing on ground (1,2).3.2.4 mobility, average, naverage of the mobility valuesfrom the mobility spectrum between 100 and 800 Hz, ex-pressed
18、in units of (m/s)/N.3.2.4.1 DiscussionThis parameter is used to comparedifferences in overall mobility among test points in the testedelement (1,2).FIG. 1 Schematic of the Test Set-Up and Apparatus for Impulse-Response TestFIG. 2 Typical Force-Time Waveform and Amplitude Spectrum Plots for Hammer wi
19、th a Hard Rubber TipC1740 1623.2.5 slope, mobility, nthe slope of the mobility spectrumobtained from the best-fit line to mobility values between 100Hz and 800 Hz.3.2.5.1 DiscussionA high mobility slope has been foundto correlate with locations of poorly consolidated (or honey-combed) concrete in pl
20、ate-like structures (1,2).3.2.6 spectrum, mobility, nthe value of mobility as afunction of frequency obtained from an impulse-response testat one point on the surface of the tested element.3.2.6.1 DiscussionThe mobility spectrum, also referred toas the transfer function, is obtained by converting th
21、e recordedwaveforms of the hammer impact force and velocity responseinto the frequency domain (3,4). The resulting spectra are usedto compute the mobility spectrum as follows:M! 5V! 3 F*!F! 3 F*!(1)where:M() = mobility spectrum,V() = velocity spectrum,F() = impact force spectrum, andF*() = complex c
22、onjugate of force spectrum.The numerator is the cross power spectrum of the forceand velocity and the denominator is the power spectrum ofthe force. Matrix multiplication by the complex conjugate ofthe force spectrum is required because the velocity andimpact force spectra are matrices of complex nu
23、mbers. Bythe rule for division of complex numbers, the numerator anddenominator have to be multiplied by the complex conjugateof the denominator, that is, the force spectrum. Fig. 3 is anexample of a mobility spectrum. The vertical axis representsresponse velocity amplitude per unit of force and the
24、horizontal axis is frequency.3.2.7 stiffness, dynamicinverse of the initial slope of themobility spectrum from 0 to 40 Hz, expressed in units of N/m(See Fig. 3).3.2.7.1 DiscussionThe initial slope of the mobility spec-trum defines the dynamic compliance (or flexibility) at the testpoint. The inverse
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17402016STANDARDPRACTICEFOREVALUATINGTHECONDITIONOFCONCRETEPLATESUSINGTHEIMPULSERESPONSEMETHOD 脉冲响应

链接地址:http://www.mydoc123.com/p-465721.html