ASTM C1703-2018 Standard Practice for Sampling of Gaseous Uranium Hexafluoride for Enrichment《浓缩用气态六氟化铀取样的标准实施规程》.pdf
《ASTM C1703-2018 Standard Practice for Sampling of Gaseous Uranium Hexafluoride for Enrichment《浓缩用气态六氟化铀取样的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1703-2018 Standard Practice for Sampling of Gaseous Uranium Hexafluoride for Enrichment《浓缩用气态六氟化铀取样的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1703 18Standard Practice forSampling of Gaseous Uranium Hexafluoride for Enrichment1This standard is issued under the fixed designation C1703; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers methods for withdrawing represen-tative sample(s) of uranium hexafluoride (UF6) during atransfer occurring in t
3、he gas phase. Such transfer in the gasphase can take place during the filling of a cylinder during acontinuous production process, for example the distillationcolumn in a conversion facility. Such sample(s) may be usedfor determining compliance with the applicable commercialspecification, for exampl
4、e Specification C787.1.2 Since UF6sampling is taken during the filling process,this practice does not address any special additional arrange-ments that may be agreed upon between the buyer and theseller when the sampled bulk material is being added toresidues already present in a container (“heels r
5、ecycle”). Sucharrangements will be based on QA procedures such as trace-ability of cylinder origin (to prevent for example contaminationwith irradiated material).1.3 If the receiving cylinder is purged after filling andsampling, special verifications must be performed by the userto verify the repres
6、entativity of the sample(s). It is thenexpected that the results found on volatile impurities with gasphase sampling may be conservative.1.4 This practice is only applicable when the transfer occursin the gas phase. When the transfer is performed in the liquidphase, Practice C1052 should apply. This
7、 practice does notapply to gas sampling after the cylinder has been filled sincethe sample taken will not be representative of the cylinder.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard t
8、o establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Prin
9、ciples for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C761 Test Methods for Chemical, Mass Spectrometric,Spectrochemical, Nuclear, and Radiochemica
10、l Analysis ofUranium HexafluorideC787 Specification for Uranium Hexafluoride for Enrich-mentC859 Terminology Relating to Nuclear MaterialsC1052 Practice for Bulk Sampling of Liquid UraniumHexafluorideC1838 Practice for Cleaning for 1S and 2S Bottles2.2 Other Document:ISO 7195 Packaging of Uranium He
11、xafluoride (UF6) forTransport33. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 containera vessel either holding or receiving bytransfer, the UF6to be sampled; it may consist of, for example,a fixed vessel in a UF6handling plant or a cylinder to be usedfor the transport of UF6.3
12、.1.2 sample vesselthe small vessel into which the sampleof UF6is withdrawn for analysis in the laboratory for charac-terization. It can be a 1S or 2S bottle or a PCTFE(polychlorotrifluoroethylene)/PTFE (polytetrafluoroethylene)pot or tube or any other type of cylinder compatible with UF6.3.2 For def
13、initions of terms used in this test method but notdefined herein, refer to Terminology C859.4. Summary of Practices4.1 A common method of withdrawing gas UF6for sam-pling utilizes a continuous withdrawal using for example acapillary to produce one sample. Depending on the pressure1This practice is u
14、nder the jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.02 on Fuel andFertile Material Specifications.Current edition approved Feb. 1, 2018. Published February 2018. Originallyapproved in 2008. Last previous edition approved in 2013 as C1
15、703 08 (2013).DOI: 10.1520/C1703-18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American
16、National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recogniz
17、ed principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1and temperature conditions during the transfer, the sampledUF6is ei
18、ther liquefied or solidified in the sample vessel.4.2 An example of this is the sampling of UF6coming froma distillation column. In such case, the sampled gas UF6can becondensed in the liquid phase in the sampling vessel. Therepresentative sample is then homogenized before analysis atthe laboratory.
19、 It is assumed that the flow rate from thedistillation is either constant (for example using a mass flowcontroller) or that the capillary will take its variation inaccount.4.3 During sampling, the presence of residues may havesignificant implications for the quality of the UF6. For safetyand quality
20、 reasons, cylinders and bottles shall be clean, dry,and empty before filling.5. Significance and Use5.1 Uranium hexafluoride is normally produced and handledin large (typically 1 to 14-ton) quantities and must, therefore,be characterized by reference to representative samples (seeISO 7195). The samp
21、les are used to determine compliance withthe applicable commercial specification C787. The quantitiesinvolved, physical properties, chemical reactivity, and hazard-ous nature of UF6are such that for representative sampling,specially designed equipment must be used and operated inaccordance with the
22、most carefully controlled and stringentprocedures. This practice can be used by UF6converters toreview the effectiveness of existing procedures or as a guide tothe design of equipment and procedures for future use.5.2 The intention of this practice is to avoid liquid UF6sampling once the cylinder ha
23、s been filled. For safety reasons,manipulation of large quantities of liquid UF6should beavoided when possible.5.3 It is emphasized that this practice is not meant to addressconventional or nuclear criticality safety issues.6. Hazards6.1 Because of its chemical, radiochemical, and toxicproperties, U
24、F6is a hazardous material.7. Principles7.1 The essential purpose of the sample(s) is to be repre-sentative of the total material which has been transferred. It isthe responsibility of the user to determine the way of continu-ous sampling or the number of samples and time distributionthat are necessa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17032018STANDARDPRACTICEFORSAMPLINGOFGASEOUSURANIUMHEXAFLUORIDEFORENRICHMENT 浓缩 气态 氟化 取样 标准 实施 规程

链接地址:http://www.mydoc123.com/p-465591.html