ASTM C1703-2008(2013) Standard Practice for Sampling of Gaseous Uranium Hexafluoride《气态六氟化铀采样的标准实施规程》.pdf
《ASTM C1703-2008(2013) Standard Practice for Sampling of Gaseous Uranium Hexafluoride《气态六氟化铀采样的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1703-2008(2013) Standard Practice for Sampling of Gaseous Uranium Hexafluoride《气态六氟化铀采样的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1703 08 (Reapproved 2013)Standard Practice forSampling of Gaseous Uranium Hexafluoride1This standard is issued under the fixed designation C1703; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers methods for withdrawing represen-tative sample(s) of uranium hexafluoride (UF6) during atransfer occurring i
3、n the gas phase. Such transfer in the gasphase can take place from a mother cylinder, for example in anautoclave to a receiving cylinder. It can also occur during thefilling in the gas phase of a cylinder during a continuousproduction process, for example centrifuge enrichment facilityor the distill
4、ation column in a conversion facility. Suchsample(s) may be used for determining compliance with theapplicable commercial specification, for example SpecificationC996 or Specification C787.1.2 Since UF6sampling is taken during the filling process,this practice does not address any special additional
5、 arrange-ments that may be agreed upon between the buyer and theseller when the sampled bulk material is being added toresidues already present in a container (“heels recycle”). Sucharrangements will be based on QA procedures such as trace-ability of cylinder origin (to prevent for example contamina
6、tionwith irradiated material).1.3 If the receiving cylinder is purged after filling andsampling, special verifications must be performed by the userto verify the representativity of the sample(s). It is thenexpected that the results found on volatile impurities with gasphase sampling may be conserva
7、tive.1.4 This practice is only applicable when the transfer occursin the gas phase. When the transfer is performed in the liquidphase, Practice C1052 should apply. This practice does notapply to gas sampling after the cylinder has been filled sincethe sample taken will not be representative of the c
8、ylinder.1.5 The scope of this practice does not include provisionsfor preventing criticality incidents.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and h
9、ealth practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C761 Test Methods for Chemical, Mass Spectrometric,Spectrochemical, Nuclear, and Radiochemical Analysis ofUranium HexafluorideC787 Specification for Uranium Hexafluoride
10、 for Enrich-mentC996 Specification for Uranium Hexafluoride Enriched toLess Than 5 %235UC1052 Practice for Bulk Sampling of Liquid UraniumHexafluoride2.2 Other Document:ISO/DIS 7195 Packaging of Uranium Hexafluoride (UF6)for Transport33. Terminology3.1 Definitions of Terms Specific to This Standard:
11、3.1.1 containera vessel either holding or receiving bytransfer, the UF6to be sampled; it may consist of, for example,a fixed vessel in a UF6handling plant or a cylinder to be usedfor the transport of UF6.3.1.2 sample vesselthe small vessel into which the sampleof UF6is withdrawn for analysis in the
12、laboratory for charac-terization. It can be a 1S or 2S bottle or a PCTFE(polydifluorodichloroethylene)/ PTFE (polytetrafluoroethyl-ene) pot or tube or any other type of cylinder compatible withUF6.4. Summary of Practices4.1 Two methods of withdrawing gas UF6for sampling arepossible, namely: (1) cont
13、inuous withdrawal using for examplea capillary and producing only one sample, or (2) sequentialwithdrawals producing a composite sample. Depending on the1This practice is under the jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.02 on Fuel
14、 andFertile Material Specifications.Current edition approved Jan. 1, 2013. Published January 2013. Originallyapproved in 2008. Last previous edition approved in 2008 as C1703 08. DOI:10.1520/C1703-08R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Ser
15、vice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 1
16、00 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1pressure and temperature conditions during the transfer, thesampled UF6is either liquefied or solidified in the samplevessel.4.2 An example of (1) is the sampling of UF6coming froma distillation column. In such case,
17、the sampled gas UF6can becondensed in the liquid phase in the sampling vessel. Therepresentative sample is then homogenized before analysis atthe laboratory. It is assumed that the flow rate from thedistillation is either constant (for example using a mass flowcontroller) or that the capillary will
18、take its variation inaccount.4.3 Examples of (2) are the sampling of UF6from anautoclave or from the cascades of an enrichment facility. Thiswould apply only to a stable process. In such case, thesequential withdrawals must take into account the potentialvariation of flow rate which must be continuo
19、usly monitoredduring the transfer. A composite sample is prepared and iscompared to an average calculation using on line analysis.4.4 For both methods of sampling, the presence of residuesmay have significant implications for the quality of the UF6.For safety and quality reasons, cylinders and bottl
20、es shall beclean, dry, and empty before filling.5. Significance and Use5.1 Uranium hexafluoride is normally produced and handledin large (typically 1 to 14-ton) quantities and must, therefore,be characterized by reference to representative samples (seeISO/DIS 7195). The samples are used to determine
21、 compliancewith the applicable commercial specifications C996 and C787.The quantities involved, physical properties, chemicalreactivity, and hazardous nature of UF6are such that forrepresentative sampling, specially designed equipment must beused and operated in accordance with the most carefullycon
22、trolled and stringent procedures. This practice can be usedby UF6converters, enrichers, and fuel fabricators to review theeffectiveness of existing procedures or as a guide to the designof equipment and procedures for future use.5.2 The intention of this practice is to avoid liquid UF6sampling once
23、the cylinder has been filled. For safety reasons,manipulation of large quantities of liquid UF6should beavoided when possible.5.3 It is emphasized that this practice is not meant to addressconventional or nuclear criticality safety issues.6. Hazards6.1 Because of its chemical, radiochemical, and tox
24、icproperties, UF6is a hazardous material.7. Principles7.1 The essential purpose of the sample(s) is to be repre-sentative of the total material which has been transferred. It isthe responsibility of the user to determine the way of continu-ous sampling or the number of samples and time distributiont
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC170320082013STANDARDPRACTICEFORSAMPLINGOFGASEOUSURANIUMHEXAFLUORIDE 气态 氟化 采样 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-465590.html