《ASTM C1702-2009a Standard Test Method for Measurement of Heat of Hydration of Hydraulic Cementitious Materials Using Isothermal Conduction Calorimetry《利用等温量热传导测量水硬性胶凝材料的水化热的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1702-2009a Standard Test Method for Measurement of Heat of Hydration of Hydraulic Cementitious Materials Using Isothermal Conduction Calorimetry《利用等温量热传导测量水硬性胶凝材料的水化热的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1702 09aStandard Test Method forMeasurement of Heat of Hydration of HydraulicCementitious Materials Using Isothermal ConductionCalorimetry1This standard is issued under the fixed designation C1702; the number immediately following the designation indicates the year oforiginal adoption
2、or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method specifies the apparatus and procedurefor determining total
3、heat of hydration of hydraulic cementi-tious materials at test ages up to 7 days by isothermalconduction calorimetry.1.2 This test method also outputs data on rate of heat ofhydration versus time that is useful for other analyticalpurposes, as covered in Practice C1679.1.3 The values stated in SI un
4、its are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pra
5、ctices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C186 Test Method for Heat of Hydration of HydraulicCementC670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsC1679 Practice for Me
6、asuring Hydration Kinetics of Hy-draulic Cementitious Mixtures Using Isothermal Calorim-etry3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 baseline, nthe time-series signal from the calorim-eter when measuring output from a sample of approximatelythe same mass and thermal pro
7、perties as a cement sample, butwhich is not generating or consuming heat.3.1.2 heat, nthe time integral of thermal power measuredin joules (J).3.1.3 isothermal conduction calorimeter, na calorimeterthat measures heat flow from a sample maintained at a constanttemperature by intimate thermal contact
8、with a constanttemperature heat sink.3.1.4 reference cell, na heat-flow measuring cell that isdedicated to measuring power from a sample that is generatingno heat.3.1.4.1 DiscussionThe purpose of the reference cell is tocorrect for baseline drift and other systematic errors that canoccur in heat-flo
9、w measuring equipment.3.1.5 sensitivity, nthe minimum change in thermal powerreliably detectable by an isothermal calorimeter.3.1.5.1 DiscussionFor this application, sensitivity is takenas ten times the random noise (standard deviation) in thebaseline signal.3.1.6 thermal power, nthe heat production
10、 rate measuredin joules per second (J/s).3.1.6.1 DiscussionThis is the property measured by thecalorimeter. The thermal power unit of measure is J/s, which isequivalent to the watt. The watt is also a common unit ofmeasure used to represent thermal power.4. Summary of Test Method4.1 PrincipleAn isot
11、hermal heat conduction calorimeterconsists of a constant-temperature heat sink to which twoheat-flow sensors and sample holders are attached in a mannerresulting in good thermal conductivity. One heat-flow sensorand sample holder contains the sample of interest. The otherheat-flow sensor is a refere
12、nce cell containing a blank samplethat evolves no heat. The heat of hydration released by thereacting cementitious sample flows across the sensor and intothe heat sink. The output from the calorimeter is the differencein heat flow (thermal power) between the sample cell and thereference cell. The he
13、at-flow sensor actually senses a smalltemperature gradient that develops across the device, howeverthe heat is removed from the hydrating sample fast enough1This test method is under the jurisdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.26 on Heat of Hy
14、dration.Current edition approved Dec. 1, 2009. Published January 2010. Originallyapproved in 2009. Last previous edition approved in 2009 as C170209. DOI:10.1520/C1702-09a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
15、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.that, fo
16、r practical purposes, the sample remains at a constanttemperature (isothermal).4.2 The output from the heat-flow sensor is an electricalvoltage signal that is proportional to the thermal power fromthe sample. This output must be calibrated to a known thermalpower. In this method this is accomplished
17、 by measurementson a heat source that emits a constant and known power level.The integral of the thermal power over the time of the test is theheat of hydration.4.3 Two methods are described. In MethodAthe sample andwater are both temperature equilibrated and mixed inside thecalorimeter. This method
18、 is the most direct way to determineheat of hydration. In Method B the sample is mixed outside ofthe calorimeter then put into the calorimeter. This methodoffers certain practicality, but depending on the materials beinganalyzed and procedures used for mixing and handling, thismethod may suffer from
19、 small errors due to periods ofhydration being missed or spurious heat being introduced ortaken away from the calorimeter during setup or combinationsthereof. Methods of correction are offered for these potentialerrors.5. Significance and Use5.1 This method is suitable for determining the total heat
20、 ofhydration of hydraulic cement at constant temperature at agesup to 7 days to confirm specification compliance. It gives testresults equivalent to Test Method C186 up to 7 days of age(Poole (2007) (4).5.2 This method compliments Practice C1679 by providingdetails of calorimeter equipment, calibrat
21、ion, and operation.Practice C1679 emphasizes interpretation significant events incement hydration by analysis of time dependent patterns ofheat flow, but does not provide the level of detail necessary togive precision test results at specific test ages required forspecification compliance.6. Apparat
22、us6.1 Miscellaneous Equipment:6.1.1 BalanceAccurate to 0.01 g.6.1.2 Volumetric DispenserA device for measuring vol-ume or mass of water, accurate to 0.1 mL. This could be asyringe, pipette, or weighing device.6.1.3 Sample HolderA device that holds the cement pasteand provides intimate contact with t
23、he calorimeter heat sensingdevice and prevents evaporation of mixing water. If usingcommercially manufactured equipment, consult the recom-mendations of the manufacturer in choosing sample holders.6.1.4 Resistance HeaterAn electrical device fabricatedfrom material with similar heat capacity and shap
24、e as the testsample, but containing a resistor connected to a constant-voltage power supply such that a stable output of 0.010 60.0002 J/s can be generated (see Note 1).NOTE 1A simple procedure for fabricating heaters and blanks havingthe same approximate shape and heat capacity as a sample is to ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17022009ASTANDARDTESTMETHODFORMEASUREMENTOFHEATOFHYDRATIONOFHYDRAULICCEMENTITIOUSMATERIALSUSINGISOTHERMALCONDUCTIONCALORIMETRY

链接地址:http://www.mydoc123.com/p-465581.html