1、Designation: C1696 15C1696 16Standard Guide forIndustrial Thermal Insulation Systems1This standard is issued under the fixed designation C1696; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers information on selection of insulation materials, systems design, application methods, protectivecoverings, guarantees, inspect
3、ion, testing, and maintenance of thermal insulation primarily for industrial applications in atemperature range of -320320 to 1200F (-195.5(195.5 to 648.8C).1.2 This guide is intended to provide practical guidelines, by applying acceptable current practice while indicating the basicprinciples by whi
4、ch new materials can be assessed and adapted for use under widely differing conditions. Design engineers, thegeneral contractors, the fabricators, and the insulation contractors will find this guide helpful.1.3 Although some insulation system designs can serve as fire protection, this guide does not
5、 address the criteria specific to thatneed. API 521 Guide for Pressure-Relieving and Depressuring Systems is recommended as a reference for fire protection. Thisguide will however address the fire properties of insulation materials.1.4 This guide is not intended for commercial, architectural, acoust
6、ical, marine, vehicle transport, or military use.1.5 This guide does not address insulation system design for refractory linings or cold boxes whereby these are typicallypackage units and of a proprietary insulation design.1.6 The values stated in inch-pound units are to be regarded as standard. The
7、 values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard
8、to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A167 Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip (Withdrawn 2014)3A240/A240M Specific
9、ation for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels andfor General ApplicationsA653/A653M Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by theHot-Dip ProcessA792/A792M Specification for Steel Sheet, 55
10、 % Aluminum-Zinc Alloy-Coated by the Hot-Dip ProcessB209 Specification for Aluminum and Aluminum-Alloy Sheet and PlateC165 Test Method for Measuring Compressive Properties of Thermal InsulationsC167 Test Methods for Thickness and Density of Blanket or Batt Thermal InsulationsC168 Terminology Relatin
11、g to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of theGuarded-Hot-Plate ApparatusC195 Specification for Mineral Fiber Thermal Insulating CementC203 Test Methods for Breaking Load and Flexural Properties of Block-Type Therma
12、l InsulationC209 Test Methods for Cellulosic Fiber Insulating Board1 This guide is under the jurisdiction of ASTM Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.40 on Insulation Systems.Current edition approved Sept. 1, 2015March 1, 2016. Published October 2
13、015March 2016. Originally approved in 2012. Last previous edition approved in 20142015 asC1696C1696 15.14a1. DOI: 10.1520/C169615.10.1520/C1696-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standard
14、svolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes
15、 have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official
16、 document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1C240 Test Methods of Testing Cellular Glass Insulation BlockC272/C272M Test Method for Water Absorption of Core Materials for Sandwich ConstructionsC302 Test Method for Density
17、 and Dimensions of Preformed Pipe-Covering-Type Thermal InsulationC303 Test Method for Dimensions and Density of Preformed Block and BoardType Thermal InsulationC335/C335M Test Method for Steady-State Heat Transfer Properties of Pipe InsulationC351 Test Method for Mean Specific Heat of Thermal Insul
18、ation (Withdrawn 2008)3C356 Test Method for Linear Shrinkage of Preformed High-Temperature Thermal Insulation Subjected to Soaking HeatC411 Test Method for Hot-Surface Performance of High-Temperature Thermal InsulationC446 Test Method for Breaking Load and Calculated Modulus of Rupture of Preformed
19、Insulation for Pipes (Withdrawn 2002)3C447 Practice for Estimating the Maximum Use Temperature of Thermal InsulationsC449 Specification for Mineral Fiber Hydraulic-Setting Thermal Insulating and Finishing CementC450 Practice for Fabrication of Thermal Insulating Fitting Covers for NPS Piping, and Ve
20、ssel LaggingC518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter ApparatusC533 Specification for Calcium Silicate Block and Pipe Thermal InsulationC534/C534M Specification for Preformed Flexible Elastomeric Cellular Thermal Insulation in Sheet and Tubular
21、 FormC547 Specification for Mineral Fiber Pipe InsulationC552 Specification for Cellular Glass Thermal InsulationC553 Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial ApplicationsC578 Specification for Rigid, Cellular Polystyrene Thermal InsulationC591 Specifi
22、cation for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal InsulationC592 Specification for Mineral Fiber Blanket Insulation and Blanket-Type Pipe Insulation (Metal-Mesh Covered) (IndustrialType)C610 Specification for Molded Expanded Perlite Block and Pipe Thermal InsulationC612 Specificat
23、ion for Mineral Fiber Block and Board Thermal InsulationC665 Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured HousingC680 Practice for Estimate of the Heat Gain or Loss and the Surface Temperatures of Insulated Flat, Cylindrical, and SphericalS
24、ystems by Use of Computer ProgramsC692 Test Method for Evaluating the Influence of Thermal Insulations on External Stress Corrosion Cracking Tendency ofAustenitic Stainless SteelC795 Specification for Thermal Insulation for Use in Contact with Austenitic Stainless SteelC871 Test Methods for Chemical
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16962016STANDARDGUIDEFORINDUSTRIALTHERMALINSULATIONSYSTEMS 工业 绝热 系统 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-465560.html