ASTM C1673-2007e1 Standard Terminology of C26 10 Nondestructive Assay Methods《C26 10无损检验法的标准术语》.pdf
《ASTM C1673-2007e1 Standard Terminology of C26 10 Nondestructive Assay Methods《C26 10无损检验法的标准术语》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1673-2007e1 Standard Terminology of C26 10 Nondestructive Assay Methods《C26 10无损检验法的标准术语》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1673 07e1Standard Terminology ofC26.10 Nondestructive Assay Methods1This standard is issued under the fixed designation C 1673; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in p
2、arentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTECorrections were made throughout editorially in October 2007.1. Scope1.1 The terminology defined in this document is associatedwith nondestructive assa
3、y of nuclear material.1.2 All of the definitions are associated with measurementtechniques that measure nuclear emissions (that is, neutrons,gamma-rays, or heat) directly or indirectly.1.3 definitions are relevant to any standards and guideswritten by subcommittee C26.10.2. Referenced Documents2.1 A
4、STM Standards:2E 456 Terminology Relating to Quality and Statistics2.2 DOE Orders:3DOE Order 435.1 Low-level Waste RequirementsDOE Order 5820.2 Radioactive Waste Management3. Terminology(alpha, n) reaction, na reaction that occurs when energeticalpha particles collide with low atomic number nucleire
5、sulting in the emission of a neutron240Pu-effective mass, nthe mass of240Pu that would pro-duce the same coincident neutron response in the instrumentas the assay item.DISCUSSIONIt is a function of the quantity of even mass isotopes ofplutonium in the assay item and fundamental nuclear constants,som
6、etimes referred to as effective240Pu mass.absorber foils, nfoils, usually of copper, tin, cadmium, orlead, used to attenuate the gamma flux reaching a detector.DISCUSSIONAbsorber foils are used to reduce the count rate,typically from intense low-energy X or gamma rays.accidentals, nthe detection of
7、multiple neutron eventswithin the gate width that are not produced from the samefission.DISCUSSIONAccidental events take their name from the fact that itis the accidental or random summing of neutrons, which are not timecorrelated with a common origin (fission or cosmic-ray burst), that giverise to
8、the appearance of a signature like that from genuine correlatedevents.accuracy, n(1) bias; (2) the closeness of a measured value tothe true value; and (3) the closeness of a measured value toan accepted reference or standard value.active assay, nassay based on the observation of radiation(s)induced
9、by irradiation from an external source.alpha, a, nthe ratio of the uncorrelated neutron emissionrate from (a, n) reactions to the spontaneous neutronemission rate from a non-multiplying item.aperture, nthe size of the opening in the collimator throughwhich the radiation of interest is intended to pa
10、ss.assay, vto determine quantitatively the amount of one ormore nuclides of interest contained in an item.attenuation correction, ncorrection to the measured countrate for attenuation of radiation that provides an estimate ofthe unattenuated radiation emission rate of the radionuclidesbeing assayed.
11、attenuation, nreduction of radiation flux due to the interac-tion of radiation with material between the source of theradiation and the detector.background, nextraneous signal superimposed on the signalof interest.Beers Law, nthe fraction of uncollided gamma rays trans-mitted through layers of equal
12、 thickness of an absorber is aconstant.benign matrix, nbulk material that has a negligible effect onthe result of the measured parameter.blank, na prepared item containing a matrix as similar aspractical to the items being measured that is free, to theextent possible, of the radionuclides of interes
13、t.1This terminology is under the jurisdiction ofASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.10 on NonDestructive Assay.Current edition approved June 1, 2007. Published July 2007.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orc
14、ontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from the U.S. Department of Energy (DOE), 1000 IndependenceAve., SW Washington, DC 20585.1Copyright ASTM International, 100
15、 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.DISCUSSIONThe most important matrix parameters are those thataffect the result of the measurement technique being used.calibration standard, nan item similar to the items to beassayed, for which the parameters of intere
16、st and all prop-erties to which the measurement technique is sensitive areknown.calorimeter, na device to measure heat or rate-of-heatgeneration.calorimetric assay, ndetermination of the mass of radioac-tive material through the measurement of its thermal powerby calorimetry and the use of nuclear d
17、ecay constants and, ifnecessary, additional isotopic measurements.certification, na written declaration from a certifying bodyor its legitimate designee that a particular measurementprocess or measurement personnel comply with stated crite-ria or that a measured item has the stated characteristics.c
18、ode validation, nprocess to determine that the softwareperforms its intended functions correctly, ensure that itperforms no unintended functions, and provides informationabout its quality and reliability.coincidence gate length, nthe time interval following thedetection of a neutron during which add
19、itional neutrons areconsidered to be in coincidence with the original neutron.coincident neutrons, ntwo or more neutrons emitted simul-taneously from a single event, such as from a nucleus duringfission.collimated detector, na detector surrounded by a shield thatimposes a directional response on the
20、 collimated detector.collimator, na shield that imposes a directional response onthe detector. Generally, for gamma ray detection the colli-mator is a hollow cylinder or rectangular prism of highatomic number (Z) and high density material, mountedcoaxially to the detector and extending over the dete
21、ctor andbeyond the detector face.Compton scattering, nscattering of gamma rays that may ormay not be from the radionuclide of interest.DISCUSSIONThe scattering reduces the energy of the gamma ray andresults in a continuum of gamma ray puted tomography, nsee tomography.confidence interval, nThe range
22、 of values, calculated fromthe probability distribution (often sufficiently well character-ized by the estimate of the mean and standard deviation),which is expected to include the population mean with astated level of confidence or likelihood.DISCUSSIONFor more details see Test Method E 456.contact
23、 measurement, na special case of a near-fieldmeasurement in which measurements are made with thedetector assembly in contact with the item, for example,tank, pipe, ductwork, being assayed.control chart, na graphical plot of test results with respectto time or sequence of measurement together with li
24、mits inwhich they are expected to lie when the system is in a stateof statistical control.control limits, nthe limits beyond which it is statisticallyhighly improbable that one or several point(s) could lie whilethe system remains in a state of statistical control.data quality objective, nmeasuremen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16732007E1STANDARDTERMINOLOGYOFC2610NONDESTRUCTIVEASSAYMETHODSC2610 无损 检验 标准 术语 PDF

链接地址:http://www.mydoc123.com/p-465467.html