ASTM C1656-2007 Standard Guide for Measuring the Reactivity of Hydraulic Refractory Castables using Exothermic Profile《用放热曲线图测量液压耐熔铸块活性的标准指南》.pdf
《ASTM C1656-2007 Standard Guide for Measuring the Reactivity of Hydraulic Refractory Castables using Exothermic Profile《用放热曲线图测量液压耐熔铸块活性的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1656-2007 Standard Guide for Measuring the Reactivity of Hydraulic Refractory Castables using Exothermic Profile《用放热曲线图测量液压耐熔铸块活性的标准指南》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1656 07Standard Guide forMeasuring the Reactivity of Hydraulic Refractory Castablesusing Exothermic Profile1This standard is issued under the fixed designation C 1656; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide applies to all castables with a reactive bindersystem that produces a measurable heat profile
3、during thesetting and hardening process. The majority of these systemswill have calcium aluminate cement as one component of thebinder system.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard
4、 to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 401 Classification of Alumina and Alumina-SilicateCastable RefractoriesC 71 Terminology Relating to RefractoriesC 862 Practice
5、for Preparing Refractory Concrete Speci-mens by Casting3. Terminology3.1 Definitions:3.1.1 EP exothermic profile, n the curve generated byplotting temperature of the embedded thermocouple versustime.3.1.2 LCC, nLow cement castable4. Significance and Use4.1 The heat of hydration of a calcium aluminat
6、e basedcastable is liberated over a short period of time (as comparedto Portland cement). This makes it easy to measure the heatprofile using off-the-shelf thermocouple equipment.4.2 The heat profile can be used to make inferences aboutthe setting and strength gain behavior of a castable andsometime
7、s the working time of a castable.4.3 Factors that should be controlled when comparing twocastables include: size, shape and mass of cast object, starttemperature of the mix, temperature of environment, and thethermal conductivity of the environment. If these factors areheld constant, then the two ca
8、stables heat profiles can becompared.4.4 The amount of heat rise created by the castable shall bea minimum of 5F. If this is not achieved, then either a largersample or better insulation (or both) should be used to increasethe measurable heat release.4.5 Varying the amount of cement in the castable,
9、 theamount of water, the type and quantity of admixtures, and soforth, will change the shape, maximum temperature and time tomaximum temperature of the curve.4.6 Following is an example of a curve generated for anLCC (see Fig. 1) that does exhibit two peaks, the first onemarking the end of working t
10、ime. In this curve one could alsoinfer that the start temperature of the mix was 24C and alsothat the hydraulic strength gain reaction was significantlystarted, but not completed by 6 h.5. Apparatus5.1 Mixing equipment as prescribed in C 862.5.2 Type T thermocouple (Type J, E, or K are also accept-a
11、ble but not preferred due to range of sensitivity. Other typescannot be used.) Wire ends should be joined by solder orwelding. Simple twisting is not recommended due to thepotential for inaccurate readings.5.3 Thermocouple sheathing (optional)5.4 Voltmeter, data acquisition card or some other instru
12、-ment to read the thermocouple mV value.5.5 Container for storage of castable during heat profilegeneration and constant temperature environment in which tostore the container.5.6 Personal computer loaded with above card will makecurve generation easier.6. Hazards6.1 There are no known hazards assoc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16562007STANDARDGUIDEFORMEASURINGTHEREACTIVITYOFHYDRAULICREFRACTORYCASTABLESUSINGEXOTHERMICPROFILE

链接地址:http://www.mydoc123.com/p-465422.html