ASTM C1650-2014 Standard Practice for Instrumental Reflectance Measurement of Color for Flat Glass Coated and Uncoated《用仪器测量涂层或无涂层平板玻璃颜色反射系数的标准实施规程》.pdf
《ASTM C1650-2014 Standard Practice for Instrumental Reflectance Measurement of Color for Flat Glass Coated and Uncoated《用仪器测量涂层或无涂层平板玻璃颜色反射系数的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1650-2014 Standard Practice for Instrumental Reflectance Measurement of Color for Flat Glass Coated and Uncoated《用仪器测量涂层或无涂层平板玻璃颜色反射系数的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1650 07C1650 14Standard Practice forInstrumental Reflectance Measurement of Color for FlatGlass, Coated, and Uncoated1This standard is issued under the fixed designation C1650; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides guidelines for the instrumental reflectance measurement of the color of fla
3、t, coated and uncoatedglass. See Terminology E284.1.2 The practice specifically excludes fluorescent and iridescent samples.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all
4、of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2244 Practice for Calcu
5、lation of Color Tolerances and Color Differences from Instrumentally Measured Color CoordinatesE284 Terminology of AppearanceE179 Guide for Selection of Geometric Conditions for Measurement of Reflection and Transmission Properties of MaterialsE308 Practice for Computing the Colors of Objects by Usi
6、ng the CIE SystemE1164 Practice for Obtaining Spectrometric Data for Object-Color EvaluationE1331 Test Method for Reflectance Factor and Color by Spectrophotometry Using Hemispherical Geometry2.2 CIE Standard:3CIE 15:2004 Colorimetry, Third Edition3. Summary of Practice3.1 The reflected color of gla
7、ss products, (see Guide E179) is measured in reflectance specular included mode on aCIE-conforming diffuse geometry instrument. (See Test Method E1331 and CIE 15:2004.) The glass color is expressed in CIEtristimulus values based on spectral transmittance measurements over the full CIE spectral range
8、 of 350 780 nm with a maximum10-nm band pass. (See CIE 15:2004 and Practice E308.) For color measurement, use of a truncated spectral range of 400 700nm is acceptable. (See CIE 15:2004.) Further information on the UV absorbing characteristics of the glass and/or glass coating orglass coating, or bot
9、h, may be determined by examining the spectral data in the 350 - 400 nm range. If the instrument allowsspectral measurement above 700 nm, useful information on the IR reflectance characteristics of the glass coating may also bedetermined. If coatings are present, they can be opaque or partially refl
10、ective.4. Significance and Use4.1 Color measurement quantifies the coating color for glass and is often related to coating thickness and composition as wellas tinting used in the substrate glass. The user of this document defines an acceptable range of color appropriate for the end use.1 This practi
11、ce is under the jurisdiction of ASTM Committee C14 on Glass and Glass Products and is the direct responsibility of Subcommittee C14.11 on OpticalProperties.Current edition approved Aug. 1, 2007May 1, 2014. Published August 2007May 2014. Originally approved in 2007. Last previous edition approved in
12、2007 as C1650 07. DOI: 10.1520/C1650-07.10.1520/C1650-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Av
13、ailable from U.S. National Committee of the CIE (International Commission on Illumination), C/o Thomas M. Lemons, TLA-Lighting Consultants, Inc., 7 Pond St.,Salem, MA 01970, http:/www.cie-usnc.org.CIE Commission Internationale de LEclairage, Wien, Austria, www.cie.co.at.This document is not an ASTM
14、standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all
15、cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1Typical quality concerns for the reflected color measurement of coated glass
16、products are an indication of consistency in the coatingprocess and verification of lot-to-lot color consistency for end-user acceptance.4.2 If the reflected color of a glass product is consistent from lot-to-lot and within agreed supplier-buyer acceptance criteria, thatproduct color is expected to
17、be consistent and acceptable for end-use.5. Apparatus5.1 For color measurements, a CIE-conforming diffuse geometry instrument capable of making reflectance measurements in thespecular included mode is required.5.2 A fixturingfixture device is required to consistently place the sample at the reflecti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16502014STANDARDPRACTICEFORINSTRUMENTALREFLECTANCEMEASUREMENTOFCOLORFORFLATGLASSCOATEDANDUNCOATED

链接地址:http://www.mydoc123.com/p-465413.html