ASTM C1650-2007 Standard Practice for Instrumental Reflectance Measurement of Color for Flat Glass Coated and Uncoated《涂覆和非涂覆平面玻璃颜色的仪器反射系数测量用标准实施规程》.pdf
《ASTM C1650-2007 Standard Practice for Instrumental Reflectance Measurement of Color for Flat Glass Coated and Uncoated《涂覆和非涂覆平面玻璃颜色的仪器反射系数测量用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1650-2007 Standard Practice for Instrumental Reflectance Measurement of Color for Flat Glass Coated and Uncoated《涂覆和非涂覆平面玻璃颜色的仪器反射系数测量用标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1650 07Standard Practice forInstrumental Reflectance Measurement of Color for FlatGlass, Coated, and Uncoated1This standard is issued under the fixed designation C 1650; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides guidelines for the instrumentalreflectance measurement of the color of flat, coa
3、ted anduncoated glass. See Terminology E 284.1.2 The practice specifically excludes fluorescent and iri-descent samples.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of the
4、safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 2244 Practice for Calculat
5、ion of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesE 284 Terminology of AppearanceE 179 Guide for Selection of Geometric Conditions forMeasurement of Reflection and Transmission Properties ofMaterialsE 308 Practice for Computing the Colors of Objects byUsing th
6、e CIE SystemE 1164 Practice for Obtaining Spectrometric Data forObject-Color EvaluationE 1331 Test Method for Reflectance Factor and Color bySpectrophotometry Using Hemispherical Geometry2.2 CIE Standard:3CIE 15:2004 Colorimetry, Third Edition3. Summary of Practice3.1 The reflected color of glass pr
7、oducts, (see Guide E 179)is measured in reflectance specular included mode on aCIE-conforming diffuse geometry instrument. (See TestMethod E 1331 and CIE 15:2004.) The glass color is expressedin CIE tristimulus values based on spectral transmittancemeasurements over the full CIE spectral range of 35
8、0 780 nmwith a maximum 10-nm band pass. (See CIE 15:2004 andPractice E 308.) For color measurement, use of a truncatedspectral range of 400 700 nm is acceptable. (SeeCIE 15:2004.) Further information on the UV absorbing char-acteristics of the glass and/or glass coating may be determinedby examining
9、 the spectral data in the 350 - 400 nm range. If theinstrument allows spectral measurement above 700 nm, usefulinformation on the IR reflectance characteristics of the glasscoating may also be determined. If coatings are present, theycan be opaque or partially reflective.4. Significance and Use4.1 C
10、olor measurement quantifies the coating color for glassand is often related to coating thickness and composition aswell as tinting used in the substrate glass. The user of thisdocument defines an acceptable range of color appropriate forthe end use. Typical quality concerns for the reflected colorme
11、asurement of coated glass products are an indication ofconsistency in the coating process and verification of lot-to-lotcolor consistency for end-user acceptance.4.2 If the reflected color of a glass product is consistentfrom lot-to-lot and within agreed supplier-buyer acceptancecriteria, that produ
12、ct color is expected to be consistent andacceptable for end-use.1This practice is under the jurisdiction of ASTM Committee C14 on Glass andGlass Products and is the direct responsibility of Subcommittee C14.11 on OpticalProperties.Current edition approved Aug. 1, 2007. Published August 2007.2For ref
13、erenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. National Committee of the CIE (International Com
14、missionon Illumination), C/o Thomas M. Lemons, TLA-Lighting Consultants, Inc., 7 PondSt., Salem, MA 01970, http:/www.cie-usnc.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Apparatus5.1 For color measurements, a CIE-conformin
15、g diffusegeometry instrument capable of making reflectance measure-ments in the specular included mode is required.5.2 A fixturing device is required to consistently place thesample at the reflection port.5.3 To prevent transmitted signal from being part of themeasurement, a light trap capable of be
16、ing mounted behind theglass sample at the reflectance port may be required to measurepartially reflective coatings.5.4 The instrument and associated color quality software/firmware shall be capable of converting measured spectralreflectance data to CIE L*, a* b*; Hunter L, a, b; or Y x, yvalues calc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16502007STANDARDPRACTICEFORINSTRUMENTALREFLECTANCEMEASUREMENTOFCOLORFORFLATGLASSCOATEDANDUNCOATED

链接地址:http://www.mydoc123.com/p-465412.html