ASTM C1637-2006 Standard Test Method for the Determination of Impurities in Plutonium Metal Acid Digestion and Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS) Analysis《钚金属中杂质.pdf
《ASTM C1637-2006 Standard Test Method for the Determination of Impurities in Plutonium Metal Acid Digestion and Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS) Analysis《钚金属中杂质.pdf》由会员分享,可在线阅读,更多相关《ASTM C1637-2006 Standard Test Method for the Determination of Impurities in Plutonium Metal Acid Digestion and Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS) Analysis《钚金属中杂质.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1637 06Standard Test Method forthe Determination of Impurities in Plutonium Metal: AcidDigestion and Inductively Coupled Plasma-MassSpectroscopy (ICP-MS) Analysis1This standard is issued under the fixed designation C 1637; the number immediately following the designation indicates the
2、 year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This Test Method covers the determination of 58 tr
3、aceelements in plutonium (Pu) metal. The Pu sample is dissolvedin acid, and the concentration of the trace impurities aredetermined by Inductively Coupled Plasma-Mass Spectros-copy (ICP-MS).1.2 This Test Method is specific for the determination oftrace impurities in Pu metal. It may be applied to ot
4、her types ofPu materials, such as Pu oxides, if the samples are dissolvedand oxidized to the Pu(IV) state. However, it is the responsi-bility of the user to evaluate the performance of other matrices.1.3 This standard does not purport to address all of thesafety concerns associated with its use. It
5、is the responsibilityof the user of this method to establish appropriate safety andhealth practices and to determine the applicability of regula-tory limitations prior to use of this standard.2. Referenced Documents2.1 ASTM Standards:2C 757 Specification for Nuclear-Grade Plutonium DioxidePowder, Si
6、nterableC 758 Test Methods for Chemical, Mass Spectrometric,Spectrochemical, Nuclear, and Radiochemical Analysis ofNuclear-Grade Plutonium MetalC 759 Test Methods for Chemical, Mass Spectrometric,Spectrochemical, Nuclear, and Radiochemical Analysis ofNuclear-Grade Plutonium Nitrate SolutionsC 1168 P
7、ractice for Preparation and Dissolution of Pluto-nium Materials for AnalysisC 1432 Test Method for Determination of Impurities inPlutonium: Acid Dissolution, Ion Exchange Matrix Sepa-ration, and Inductively Coupled Plasma-Atomic EmissionSpectroscopic (ICP/AES) AnalysisD 1193 Specification for Reagen
8、t Water3. Summary of Test Method3.1 A sample of Pu metal is dissolved in a small volume of6 M hydrochloric acid (HCl). Then, 10 M nitric acid (HNO3)/0.03 M hydrofluoric acid (HF) is added to the dissolved Pu tooxidize the Pu to the Pu(IV) state. An aliquot of the originalsample is taken and diluted
9、with 1 % HNO3by volume to aprescribed volume. Aliquots from a second dilution of theoriginal sample are used to prepare run batch dilutions that areanalyzed for trace impurities by ICP-MS.34. Significance and Use4.1 This test method may be run together with Test MethodC 1432 to analyze for trace imp
10、urities in Pu metal. Using thetechnique described in this test method and the techniquedescribed in Test Method C 1432 will provide the analyst witha more thorough verification of the impurity concentrationscontained in the Pu metal sample. In addition, Test MethodC 1432 can be used to determine imp
11、urity concentrations foranalytes such as Ca, Fe, Na, and Si, which have not beendetermined using this test method.4.2 This test method can be used on Pu matrices in nitratesolutions.4.3 This test method has been validated for use on materialsthat meet the specifications described in Specification C
12、757and Test Methods C 758 and C 759.4.4 This test method has been validated for all elementslisted in Table 1.5. Interferences5.1 Ions from doubly charged (2+) species are formed in theICP-MS. The actinide related spectral interferences are fromactinide 2+ and actinide-oxide 2+. The spectral interfe
13、rences1This test method is under the jurisdiction ofASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.05 on Methods ofTest.Current edition approved Jan. 1, 2006. Published February 2006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, o
14、rcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3“Inductively Coupled Plasma Mass Spectrometry Using the VG ElementalPlasma Quad”, Actinide Analytical Chemistry Procedures, Los Ala
15、mos NationalLaboratory, ANC102 R.1.2, LA-UR-05-7605, 2004.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.are observed at 120.5 and 127.5 atomic mass unit (amu), whenanalyzing plutonium-239.5.2 Spectral interferences from the argon p
16、lasma and theacid used to transport the sample to the plasma. These spectralinterferences occur between 12 and 80 amu.5.3 Ions from plutonium cause a matrix related signalsuppression. Signal suppression increases as the Pu concentra-tion increases. In order to minimize signal suppression effectsfrom
17、 Pu, samples are diluted so that the concentration of Pu inthe analyzed aliquot is less than 500 g/mL. Three internalstandards are added to samples to correct for matrix relatedsignal suppression and signal drift. Scandium, rhodium andthulium are used as internal standards. Analytes at the low endof
18、 the mass range (below 75 amu) are referenced to scandium.Rhodium is a reference for analytes at the middle of the massrange (76-138) and all analytes at the high end of the massrange are referenced to thulium (139-238 amu).6. Apparatus6.1 An ICP-MS instrument with a quadrupole mass spec-trometer an
19、d a electron multiplier that operates at 1 amuresolution is used for this determination. The instrument canalso be a magnetic sector instrument or a time of flightinstrument.6.2 The ICP-MS is interfaced to a glovebox. The torch box,and the analyzer region of the mass spectrometer are gloveboxenclose
20、d, since Pu containing materials come in direct contactwith these sections of the instrument. Methods for enclosingplasma spectroscopic sources so that hazardous materials canbe analyzed safely are described in ASTM STP 951.46.3 Graduated 14 mL disposable plastic round bottom tubesand caps or simila
21、r.6.4 Electronic pipettes.7. Reagents and Materials7.1 Ultra high purity acids shall be used for sample disso-lution and calibration standards preparation unless otherwisenoted.57.2 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatal
22、l reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society(ACS), where such specification are available.67.3 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean laboratory accepteddemineralized or dei
23、onized water as described by Type I ofSpecification D 1193.NOTE 1The molarity of ultra high purity acids may vary fromstandard ACS specifications for concentrated acids.NOTE 2All reagents are prepared and stored in polytetrafluoroethyl-ene (PTFE) containers.7.4 Hydrochloric Acid (HCl, 11.3 M), conce
24、ntrated HCl.4Edellson, M. C., and Daniel, J. Leland, “Plasma Spectroscopy of the Analysisof Hazardous Materials: Design and Application of Enclosed Plasma Sources,”Conference Proceedings, ASTM 951, ASTM, 1986.5“The ULTREX II (J. T. Baker) and INSTRUMENT QUALITY (SeastarChemicals) lines of ultra high
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16372006STANDARDTESTMETHODFORTHEDETERMINATIONOFIMPURITIESINPLUTONIUMMETALACIDDIGESTIONANDINDUCTIVELYCOUPLEDPLASMAMASSSPECTROSCOPYICPMSANALYSIS

链接地址:http://www.mydoc123.com/p-465377.html