ASTM C1621 C1621M-2009 Standard Test Method for Passing Ability of Self-Consolidating Concrete by J-Ring.pdf
《ASTM C1621 C1621M-2009 Standard Test Method for Passing Ability of Self-Consolidating Concrete by J-Ring.pdf》由会员分享,可在线阅读,更多相关《ASTM C1621 C1621M-2009 Standard Test Method for Passing Ability of Self-Consolidating Concrete by J-Ring.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1621/C 1621M 09Standard Test Method forPassing Ability of Self-Consolidating Concrete by J-Ring1This standard is issued under the fixed designation C 1621/C 1621M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers determination of the passingability of self-consolidating concrete by using the J-Rin
3、g incombination with a slump cone mold. The test method islimited to concrete with nominal maximum size of aggregate ofup to 1 in 25 mm.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. Within the text, theSI units are shown in brackets. The value
4、s stated in eachsystem may not be exact equivalents; therefore, each systemshall be used independently of the other. Combining valuesfrom the two systems may result in non-conformance with thestandard.1.3 The text of this standard references notes that provideexplanatory material. These notes (exclu
5、ding those in tablesand figures) shall not be considered as requirements of thestandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices
6、 and determine the applica-bility of regulatory limitations prior to use. (WarningFreshhydraulic cementitious mixtures are caustic and may causechemical burns to skin and tissue upon prolonged exposure.)22. Referenced Documents2.1 ASTM Standards:3C 125 Terminology Relating to Concrete and ConcreteAg
7、gregatesC 143/C 143M Test Method for Slump of Hydraulic-Cement ConcreteC 172 Practice for Sampling Freshly Mixed ConcreteC 173/C 173M Test Method for Air Content of FreshlyMixed Concrete by the Volumetric MethodC 1611/C 1611M Test Method for Slump Flow of Self-Consolidating Concrete3. Terminology3.1
8、 Definitions:3.1.1 For definitions of terms used in this test method, referto Terminology C 125.3.2 Definitions of Terms Specific to This Standard:3.2.1 halo, nan observed cement paste or mortar ring thathas clearly separated from the coarse aggregate, around theoutside circumference of concrete aft
9、er flowing from the slumpcone.3.2.2 J-ring, nan apparatus consisting of a rigid ringsupported on sixteen58 in. 16 mm diameter rods equallyspaced on a 12 in. 300 mm diameter circle 4 in. 100 mmabove a flat surface as shown in Fig. 1.3.2.3 J-ring flow, nthe distance of lateral flow of concreteusing th
10、e J-Ring in combination with a slump cone.3.2.4 passing ability, nthe ability of self-consolidatingconcrete to flow under its own weight (without vibration) andfill completely all spaces within intricate formwork, containingobstacles, such as reinforcement.4. Summary of Test Method4.1 A sample of fr
11、eshly mixed concrete is placed in a slumpmold, either in the upright or inverted position, that isconcentric with the J-Ring (Fig. 2). The concrete is placed inone lift without tamping or vibration. The mold is raised, andthe concrete is allowed to spread through the J-Ring (Fig. 3).After spreading
12、ceases, two diameters of the concrete mass aremeasured in approximately orthogonal directions. J-Ring flowis the average of the two diameters. The test is repeated withoutthe J-Ring to obtain the slump flow. The difference between theslump flow and J-Ring flow is an indicator of the passingability o
13、f the concrete.5. Significance and Use5.1 This test method provides a procedure to determine thepassing ability of self-consolidating concrete mixtures. Thedifference between the slump flow and J-Ring flow is anindication of the passing ability of the concrete. A difference1This test method is under
14、 the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.47 on Self-Consolidating Concrete.Current edition approved May 1, 2009. Published June 2009. Originallyapproved in 2006. Last previous edition approved in 2008 as C 1621/C 1
15、621M 08.2Section on Safety Precautions, Manual of Aggregate and Concrete Testing,Annual Book of ASTM Standards, Vol. 04.02.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, re
16、fer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.less than 1 in. 25 mm indicates good passing ability and
17、adifference greater than 2 in. 50 mm indicates poor passingability. The orientation of the slump cone for the J-Ring testand for the slump flow test without the J-Ring shall be thesame.5.2 This test method is applicable for laboratory use incomparing the passing ability of different concrete mixture
18、s. Itis also applicable in the field as a quality control test.6. Apparatus6.1 J-RingThe apparatus shall consist of a steel (orequivalent nonabsorbent, rigid material) ring measuring 12 in.300 mm in diameter at the center of the ring and 1 in. 25mm in thickness, and sixteen58 in. 16 mm diameter smoo
19、thsteel rods spaced evenly around the ring measuring 4 in. 100mm in length (see Fig. 1).6.2 MoldThe mold (slump cone) used in this test methodis as described in Test Method C 143/C 143M, except that thefoot pieces are removed when the test is performed with themold in the upright position (Procedure
20、 A).6.3 Base PlateA nonabsorbent, rigid plate having a diam-eter of at least 36 in. 915 mm.NOTE 1Field experience has shown that base plates made from sealedor laminated plywood, rigid plastic, or steel are suitable for performingthis test.6.4 Strike Off BarAs described in Test Method C 173/C 173M.6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1621C1621M2009STANDARDTESTMETHODFORPASSINGABILITYOFSELFCONSOLIDATINGCONCRETEBYJRINGPDF

链接地址:http://www.mydoc123.com/p-465331.html