1、Designation: C 1611/C 1611M 09aStandard Test Method forSlump Flow of Self-Consolidating Concrete1This standard is issued under the fixed designation C 1611/C 1611M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of slump flowof self-consolidating concrete.1.2 The values stated in either SI un
3、its or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 The text of this sta
4、ndard references notes and footnotesthat provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
5、is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. (WARNINGFresh hydraulic cementitious mixtures are caustic and maycause chemical burns to skin and tissue upon prolongedexpo
6、sure.2)2. Referenced Documents2.1 ASTM Standards:3C 125 Terminology Relating to Concrete and ConcreteAggregatesC 143/C 143M Test Method for Slump of Hydraulic-Cement ConcreteC 172 Practice for Sampling Freshly Mixed ConcreteC 173/C 173M Test Method for Air Content of FreshlyMixed Concrete by the Vol
7、umetric MethodC 670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction Materials3. Terminology3.1 For definitions of terms used in this test method, refer toTerminology C 125.3.2 Definitions of Terms Specific to This Standard:3.2.1 halo, nan observed cement paste o
8、r mortar ring thathas clearly separated from the coarse aggregate, around theoutside circumference of concrete after flowing from the mold.3.2.2 spread, nthe distance of lateral flow of concreteduring the slump-flow test.3.2.3 stability, nthe ability of a concrete mixture to resistsegregation of the
9、 paste from the aggregates.3.2.4 viscosity, nresistance of a material to flow under anapplied shearing stress.4. Summary of Test Method4.1 A sample of freshly mixed concrete is placed in a moldshaped as the frustum of a cone. The concrete is placed in onelift without tamping or vibration. The mold i
10、s raised, and theconcrete allowed to spread. After spreading ceases, two diam-eters of the concrete mass are measured in approximatelyorthogonal directions, and slump flow is the average of the twodiameters.5. Significance and Use5.1 This test method provides a procedure to determine theslump flow o
11、f self-consolidating concrete in the laboratory orthe field.5.2 This test method is used to monitor the consistency offresh, unhardened self-consolidating concrete and its uncon-fined flow potential.5.3 It is difficult to produce self-consolidating concrete thatis both flowable and nonsegregating us
12、ing coarse aggregateslarger than 25 mm 1 in. Therefore, this test method isconsidered applicable to self-consolidating concrete havingcoarse aggregate up to 25 mm 1 in. in size. Appendix X11This test method is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the
13、 direct responsibility of SubcommitteeC09.47 on Self-Consolidating Concrete.Current edition approved June 1, 2009. Published July 2009. Originally approvedin 2009. Last previous edition approved in 2009 as C 1611/C 1611M 09.2Section on Safety Precautions, Manual of Aggregate and Concrete Testing,Ann
14、ual Book of ASTM Standards, Vol. 04.02.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes
15、 section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.provides non-mandatory visual rating criteria that may be usedto classify the ability of a self-consolidating concrete mixtureto resist segre
16、gation (stability).5.4 The rate at which the concrete spreads is related to itsviscosity. Appendix X1 provides a non-mandatory procedurethat may be used to provide an indication of relative viscosityof self-consolidating concrete mixtures.6. Apparatus6.1 MoldThe mold used in this test method shall c
17、onformto that described in Test Method C 143/C 143M.6.2 Base PlateThe base plate on which the mold restsshall be nonabsorbent, smooth, rigid, and have a minimumdiameter of 915 mm 36 in. (See Note 1).NOTE 1Field experience and results from the round robin testprogram have shown that base plates made
18、from sealed/laminatedplywood, acrylic plastic, or steel are suitable for performing this test.6.3 Strike-off BarAs described in Test Method C 173/C 173M.7. Sample7.1 The sample of concrete from which test specimens aremade shall be representative of the entire batch. It shall beobtained in accordanc
19、e with Practice C 172.8. Procedure8.1 Perform the test on a flat, level, nonabsorbent surfacesuch as a concrete floor or a base plate. Use the base plate inconditions where a flat, level surface is not available, such ason a construction site. When the base plate is used, position andshim the base p
20、late so that it is fully supported, flat, and level.Pre-moisten the work surface or base plate with a damp towel,rag, or sponge.8.1.1 When performing the slump flow test for a given studyor project, do not change the base plate surface type for theduration of the study or project.8.2 Filling the Mol
21、d: Fill the mold by following eitherProcedure A or Procedure B (See Note 2).8.2.1 Filling Procedure A (Upright Mold): Dampen themold and place it on the work surface, or centered on the baseplate, with the larger opening facing down. Hold the moldfirmly in place during filling by standing on the two
22、 footpieces. Fill the mold in a continuous manner (See Note 3).Overfill the mold slightly above its top.8.2.2 Filling Procedure B (Inverted Mold): Dampen themold and place it on the work surface, or centered on the baseplate, with the smaller opening facing down (See Note 4). Fillthe mold in a conti
23、nuous manner (See Note 3). Overfill themold slightly above its top.NOTE 2During the development of this test method, it was found thatsome of the users preferred to perform the test with the large opening ofthe mold facing down as is performed in Test Method C 143/C 143M. Theprovision of a collar to
24、 the top of the mold is useful to reduce theprobability of concrete spilling over the mold and on to the base plate.Other users preferred to place the mold with the smaller opening facedown, which facilitates the ease of filling. Both filling procedures havebeen found to be suitable when performing
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1611C1611M2009ASTANDARDTESTMETHODFORSLUMPFLOWOFSELFCONSOLIDATINGCONCRETEPDF

链接地址:http://www.mydoc123.com/p-465294.html