ASTM C1605-2004 Standard Test Methods for Chemical Analysis of Ceramic Whiteware Materials Using Wavelength Dispersive X-Ray Fluorescence Spectrometry《使用波长色散X射线荧光光谱法进行白色陶瓷材料化学分析的标准.pdf
《ASTM C1605-2004 Standard Test Methods for Chemical Analysis of Ceramic Whiteware Materials Using Wavelength Dispersive X-Ray Fluorescence Spectrometry《使用波长色散X射线荧光光谱法进行白色陶瓷材料化学分析的标准.pdf》由会员分享,可在线阅读,更多相关《ASTM C1605-2004 Standard Test Methods for Chemical Analysis of Ceramic Whiteware Materials Using Wavelength Dispersive X-Ray Fluorescence Spectrometry《使用波长色散X射线荧光光谱法进行白色陶瓷材料化学分析的标准.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1605 04Standard Test Methods forChemical Analysis of Ceramic Whiteware Materials UsingWavelength Dispersive X-Ray Fluorescence Spectrometry1This standard is issued under the fixed designation C 1605; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination of ten majorelements (SiO2,Al2
3、O3,Fe2O3, MgO, CaO, Na2O, K2O, TiO2,P2O5, MnO, and LOI in ceramic whitewares clays and mineralsusing wavelength dispersive X-ray fluorescence spectrometry(WDXRF). The sample is first ignited, then fused with lithiumtetraborate and the resultant glass disc is introduced into awavelength dispersive X-
4、ray spectrometer. The disc is irradi-ated with X-rays from an X-ray tube. X-ray photons emitted bythe elements in the samples are counted and concentrationsdetermined using previously prepared calibration standards.(1)2In addition to 10 major elements, the method provides agravimetric loss-on-igniti
5、on.NOTE 1Much of the text of this test method is derived directly fromMajor element analysis by wavelength dispersive X-ray fluorescencespectrometry, included in Ref (1).1.2 Interferences, with analysis by WDXRF, may resultfrom mineralogical or other structural effects, line overlaps,and matrix effe
6、cts. The structure of the sample, mineralogicalor otherwise, is eliminated through fusion with a suitable flux.Fusion of the sample diminishes matrix effects and produces astable, flat, homogeneous sample for presentation to thespectrometer. Selecting certain types of crystal monochroma-tors elimina
7、tes many of the line overlaps and multiorder lineinterferences. A mathematical correction procedure (2) is usedto correct for the absorption and enhancement matrix effects.1.3 Concentrations of the elements in clays and minerals aredetermined independent of the oxidation state and are reportedin the
8、 oxidation state in which they most commonly occur inthe earths crust.1.4 Concentration ranges:ElementConcentration range(percent)SiO20.10 99.0Al2O30.10 58.0Fe2O30.04 28.0MgO 0.10 60.0ElementConcentration range(percent)CaO 0.02 60.0Na2O 0.15 30.0K2O 0.02 30.0TiO20.02 10.0P2O50.05 50.0MnO 0.01 15.0LO
9、I (925C) 0.01 100.01.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to
10、use.2. Referenced Documents2.1 ASTM Standards:3C 242 Terminology of Ceramic Whitewares and RelatedProductsC 322 Test Method for Sampling Ceramic Whiteware ClaysC 323 Test Methods for Chemical Analysis of CeramicWhiteware Clays3. Apparatus3.1 Simultaneous X-ray Spectrometer, for example, PhilipsPW160
11、6 or equivalent.3.2 Pt-Au Alloy Crucibles and Molds, (3).3.3 Fluxer,(4) or equivalent).3.4 Two Muffle Furnaces with Rocker AttachmentsAmuffle furnace is not required if the fluxer has automaticoperation with its own heat source.3.5 Hot Plate and Muffle Furnace.4. Reagents4.1 Digest the samples in Jo
12、hnson Matthey Spectroflux 1004or equivalent brand (lithium tetraborate). A blend of lithiumtetraborate (Spectroflux 1004) and lithium metaborate (Spec-troflux 100A4) can be used if a lower fusion point is desired.1These test methods are under the jurisdiction of ASTM Committee C21 onCeramic Whitewar
13、es and Related Products and are the direct responsibility ofSubcommittee C21.03 on Methods for Whitewares and Environmental Concerns.Current edition approved August 1, 2004. Published October 2004.2The boldface numbers in parentheses refer to the list of references at the end ofthis standard.3For re
14、ferenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Spectroflux is a registered tradmark of Johnson Matthey, Johnson Ma
15、tthey Plc2-4 Cockspur Street, Trafalgar Square, London, SW1Y 5BQ, United Kingdom.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.The flux is ordered in powdered form, lot size as appropriate,and identified by number and date.4.2 Dry
16、the minus 60-mesh material for the lot 2 days at300C and keep in sealed Mason jars.4.3 After drying, perform a loss-on-fusion for each lot offlux from the manufacturer so that an appropriate amount offlux can be weighed out to yield 8.0000 g of lithium tetraborateafter fusion.4.4 Weigh the charges o
17、f flux using a Zymark5robot to60.0035 g (60.04 % precision). If the Zymark5robot is notavailable the samples can be weighed by hand.4.5 Clean the platinum ware in 50 percent reagent gradeHCl, rinse in deionized water and dry at 140C. Other acidsmay be used instead of HCl, depending on the preference
18、 of thelaboratory.4.6 Prepare the LiBr used as a nonwetting agent by neutral-izing reagent grade concentrated HBr (48 %) with LiCO3.4.7 Filter the LiBr solution and dilute 1:1 with deionizedwater.5. Safety Precautions5.1 Fusions and ignitions of samples in a muffle furnacemust be performed under a h
19、igh velocity canopy hood. Boilingof the HCl cleaning solution is performed in a chemical fumehood with a safety sash. Safety glasses and special nonflam-mable, nonasbestos, heat resistant gloves must be worn whenremoving the fluxer from the muffle furnace. Glass discs aresharp on the rear edge and s
20、hould be handled with care. Dustfrom the flux must not be inhaled, so pouring of the powderedflux must be done in a chemical hood. Preparation of the LiBrsolution must be done by slowly adding LiCO3to the HBr sothe generation of CO2does not cause the acid to spill over theedge of the beaker. The spe
21、cific Chemical Hygiene Plan (CHP)for the laboratory, or laboratories if the corporation has morethan one, gives the first-aid treatment and disposal proceduresfor chemical products used in this method.6. Procedure6.1 Ignite a 0.8000 g portion of minus 80-mesh sample in atared 95 percent Pt/5 percent
22、 Au crucible at 925C for 40minutes. Report the weight loss as percent loss on ignition(LOI).6.2 Add a charge of lithium tetraborate (or a blend oflithium tetraborate/lithium metaborate) that will contribute8.0000 g after fusion to the sample and thoroughly mix thepowders.6.3 The combined weights of
23、the sample and the flux willresult in an “infinitely thick” sample disc to the instrument.6.4 Add a 0.250 mL aliquot of the 1:1 LiBr solution, servingas a nonwetting agent, to the sample.6.5 Load whatever number of crucibles (with samples) andmolds the fluxer is equipped to hold and the same number
24、ofempty molds onto the fluxer.6.6 Following the instructions of the fluxer, allow it to reacha temperature of 1120C for ten minutes, and then rock for 5minutes to stir and homogenize the samples. If sulfur is to bedetermined, fusion temperature must be 1050C or less and theblend of lithium tetrabora
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16052004STANDARDTESTMETHODSFORCHEMICALANALYSISOFCERAMICWHITEWAREMATERIALSUSINGWAVELENGTHDISPERSIVEXRAYFLUORESCENCESPECTROMETRY

链接地址:http://www.mydoc123.com/p-465270.html