《ASTM C1574-2004(2013) Standard Guide for Determining Blown Density of Pneumatically Applied Loose-Fill Mineral Fiber Thermal Insulation《喷射松填充矿物纤维热绝缘材料膨胀密度测定的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1574-2004(2013) Standard Guide for Determining Blown Density of Pneumatically Applied Loose-Fill Mineral Fiber Thermal Insulation《喷射松填充矿物纤维热绝缘材料膨胀密度测定的标准指南》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1574 04 (Reapproved 2013)Standard Guide forDetermining Blown Density of Pneumatically Applied Loose-Fill Mineral Fiber Thermal Insulation1This standard is issued under the fixed designation C1574; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide describes two alternate procedures for deter-mining blown density a
3、t a predetermined thickness or a rangeof thicknesses expected in field applications of mineral fiberloose-fill insulation.1.2 This guide involves blowing a sample of loose-fillinsulation into a test frame of known volume, measuring theweight of the insulation captured and calculating the blowndensit
4、y.1.3 This guide is intended for pneumatically-applied loose-fill mineral fiber insulation designed for use in horizontal openattic spaces.1.4 This guide is intended for product design and productauditing by manufacturers of loose-fill insulation. This guide isadaptable as a plant quality control pr
5、ocedure.1.5 This guide does not predict the aged density of themineral fiber loose-fill insulation.1.6 This standard does not purport to address all the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth pra
6、ctices and to determine the applicability of regula-tory limitations prior to use.1.7 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.2.
7、Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC1374 Test Method for Determination of Installed Thick-ness of Pneumatically Applied Loose-Fill Building Insu-lation3. Terminology3.1 DefinitionsTerminology C168 is applicable to theterms used in this standard.3.2
8、 Definitions of Terms Specific to This Standard:3.2.1 Variable blown densitychange in density exhibitedby loose-fill insulation as a function of thickness.3.2.1.1 DiscussionSome loose-fill insulation materials ex-hibit an increase in blown density when thickness increases.Also, the original thicknes
9、s may or may not decrease with timeresulting in the same or somewhat higher densities. Thisthickness vs density relationship should be considered whendeveloping coverage information for the bag label.4. Significance and Use4.1 Blown density is used to develop loose-fill coveragecharts. Data for blow
10、n density vs thickness is used in thedevelopment of a variable blown density presentation forloose-fill insulation.4.2 Thermal resistance (and conductivity) of loose-fill min-eral fiber insulation depends on density and thickness. Theresulting blown density data is useful in developing an expres-sio
11、n for apparent thermal conductivity as a function of density.This will in turn aid the manufacturer in developing coverageinformation for packages of loose-fill insulation.4.3 The blown density obtained in this method is for thethickness of the test only. The relationship of blown densitywith thickn
12、ess can be determined by repeating the proceduresoutlined here using different thicknesses.4.4 These procedures are not the same as the test methoddescribed in Test Method C1374. Depending on the testconditions utilized, the blown density may, or may not,represent the installed density values obtain
13、ed by using TestMethod C1374.4.5 This guide can be used to develop appropriate blowingmachine settings to achieve a target blown density at apredetermined thickness.1This guide is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.3
14、2 on MechanicalProperties.Current edition approved March 1, 2013. Published March 2013. Originallyapproved in 2004. Last previous edition approved in 2008 as C157404(2008)1.DOI: 10.1520/C1574-04R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service
15、at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Summary of Guide5.1 A standardized test chambe
16、r of fixed volume is used tocollect the pneumatically-applied insulation.5.2 There are two types of test chambers that are in commonuse:5.2.1 Procedure A uses a moveable test box having aminimum volume of 20 cubic feet (0.56 m3) . The blownmaterial is weighed while still in the test box and the dens
17、ity iscalculated.5.2.2 Procedure B uses a fixed frame assembly in a testroom or blowing shack to simulate an attic application. Theblown material is removed from the test frame and weighedseparately to calculate the density.5.3 After the insulation is blown into the chamber, theweight of the insulat
18、ion is determined.5.4 From the volume of the sample and its weight, theblown density is determined.6. Apparatus6.1 Blowing Machinea commercial pneumatic blowingmachine, designed for handling mineral fiber loose-fill insula-tion materials, shall be used for blowing the insulation into thetest chamber
19、. This machine shall have throughput and handlingcharacteristics representative of that used in field applications.6.2 Blowing Hosethe machine shall utilize three (3) 50 ft(15 m) sections to make up 150 ft (46 m) of a minimum of 3in. (76 mm) diameter flexible corrugated blowing hose.At least100 ft.
20、(30 m) of the hose shall have an elevation of between10 and 20 ft (3 and 6 m) above the blowing machine tosimulate a typical installation configuration. The hose shallhave no more than eight 90-degree bends and no bends may beless than 4 ft (1.2 m) radius. After 50 h of usage, the last 50 ft(15 m) s
21、ection at the discharge end shall be discarded. A new50 ft (15 m) shall be attached directly to the blowing woolmachine. The remaining 100 ft (30 m) shall then be attached tothe end of the new hose. This creates a hose replacementrotation.6.3 Scalesplatform scales or load cells accurate to 1 %.6.4 S
22、pecimen Preparation Rooman enclosed area wherethe test material is to be blown into the test chamber. This areais required to protect the blowing operation from wind orstrong air currents. Room geometry should provide adequateclearance around the test chamber and large enough not toinfluence the blo
23、wing stream from the hose.6.5 Hose Nozzle Standa hose stand on casters that holdsthe blowing hose at a fixed height of 36 to 48 in. (0.9 to 1.2 m)and is on a swivel that allows the operator to swing the hosehorizontally back and forth while slowly moving backwardsFIG. 1 Hose Nozzle StandC1574 04 (20
24、13)2and forwards to fill the test chamber. A typical hose nozzlestand is shown in Fig. 1. Use of the hose stand is optional.6.6 Moveable Test Chamber (Procedure A)a wooden opencontainer to collect the insulation. The chamber shall have aminimum capacity of 20 ft3(0.57 m3) and have the minimuminside
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC157420042013STANDARDGUIDEFORDETERMININGBLOWNDENSITYOFPNEUMATICALLYAPPLIEDLOOSEFILLMINERALFIBERTHERMALINSULATION

链接地址:http://www.mydoc123.com/p-465173.html