ASTM C1574-2004(2008) Standard Guide for Determining Blown Density of Pneumatically Applied Loose-Fill Mineral Fiber Thermal Insulation.pdf
《ASTM C1574-2004(2008) Standard Guide for Determining Blown Density of Pneumatically Applied Loose-Fill Mineral Fiber Thermal Insulation.pdf》由会员分享,可在线阅读,更多相关《ASTM C1574-2004(2008) Standard Guide for Determining Blown Density of Pneumatically Applied Loose-Fill Mineral Fiber Thermal Insulation.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1574 04 (Reapproved 2008)Standard Guide forDetermining Blown Density of Pneumatically Applied Loose-Fill Mineral Fiber Thermal Insulation1This standard is issued under the fixed designation C 1574; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide describes two alternate procedures for deter-mining blown density
3、 at a predetermined thickness or a rangeof thicknesses expected in field applications of mineral fiberloose-fill insulation.1.2 This guide involves blowing a sample of loose-fillinsulation into a test frame of known volume, measuring theweight of the insulation captured and calculating the blowndens
4、ity.1.3 This guide is intended for pneumatically-applied loose-fill mineral fiber insulation designed for use in horizontal openattic spaces.1.4 This guide is intended for product design and productauditing by manufacturers of loose-fill insulation. This guide isadaptable as a plant quality control
5、procedure.1.5 This guide does not predict the aged density of themineral fiber loose-fill insulation.1.6 This standard does not purport to address all the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth p
6、ractices and to determine the applicability of regula-tory limitations prior to use.1.7 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.2
7、. Referenced Documents2.1 ASTM Standards:2C 168 Terminology Relating to Thermal InsulationC 1374 Test Method for Determination of Installed Thick-ness of Pneumatically Applied Loose-Fill Building Insula-tion3. Terminology3.1 DefinitionsTerminology C 168 is applicable to theterms used in this standar
8、d.3.2 Definitions of Terms Specific to This Standard:3.2.1 Variable blown densitychange in density exhibitedby loose-fill insulation as a function of thickness.3.2.1.1 DiscussionSome loose-fill insulation materials ex-hibit an increase in blown density when thickness increases.Also, the original thi
9、ckness may or may not decrease with timeresulting in the same or somewhat higher densities. Thisthickness vs density relationship should be considered whendeveloping coverage information for the bag label.4. Significance and Use4.1 Blown density is used to develop loose-fill coveragecharts. Data for
10、 blown density vs thickness is used in thedevelpoment of a variable blown density presentation forloose-fill insulation.4.2 Thermal resistance (and conductivity) of loose-fill min-eral fiber insulation depends on density, thickness. The result-ing blown density data is useful in developing an expres
11、sionfor apparent thermal conductivity as a function of density. Thiswill in turn aid the manufacturer in developing coverageinformation for packages of loose-fill insulation.4.3 The blown density obtained in this method is for thethickness of the test only. The relationship of blown densitywith thic
12、kness can be determined by repeating the proceduresoutlined here using different thicknesses.4.4 These procedures are not the same as the test methoddescribed in Test Method C 1374. Depending on the testconditions utilized, the blown density may, or may not,represent the installed density values obt
13、ained by using TestMethod C 1374.4.5 This guide can be used to develop appropriate blowingmachine settings to achieve a target blown density at apredetermined thickness.1This guide is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C
14、16.32 on MechanicalProperties.Current edition approved Dec. 1, 2008. Published February 2009. Originallyapproved in 2004. Last previous edition approved in 2004 as C 157404.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For A
15、nnual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Summary of Guide5.1 A standardized test chamber of fixed volume is use
16、d tocollect the pneumatically-applied insulation.5.2 There are two types of test chambers that are in commonuse:5.2.1 Procedure A uses a moveable test box having aminimum volume of 20 cubic feet (0.56 m3) . The blownmaterial is weighed while still in the test box and the density iscalculated.5.2.2 P
17、rocedure B uses a fixed frame assembly in a testroom or blowing shack to simulate an attic application. Theblown material is removed from the test frame and weighedseparately to calculate the density.5.3 After the insulation is blown into the chamber, theweight of the insulation is determined.5.4 Fr
18、om the volume of the sample and its weight, theblown density is determined.6. Apparatus6.1 Blowing Machinea commercial pneumatic blowingmachine, designed for handling mineral fiber loose-fill insula-tion materials, shall be used for blowing the insulation into thetest chamber. This machine shall hav
19、e throughput and handlingcharacteristics similar to that used in field applications.6.2 Blowing Hosethe machine shall utilize three (3) 50 ft(15 m) sections to make up 150 ft (46 m) of a minimum of 3in. (76 mm) diameter flexible corrugated blowing hose.At least100 ft. (30 m) of the hose shall be ele
20、vated between 10 and 20ft (3 and 6 m) above the blowing machine to simulate a typicalinstallation configuration. The hose shall have no more thaneight 90-degree bends and no bends may be less than 4 ft (1.2m) radius. After 50 h of usage, the last 50 ft (15 m) section atthe discharge end shall be dis
21、carded. A new 50 ft (15 m) shallbe attached directly to the blowing wool machine. The remain-ing 100 ft (30 m) shall then be attached to the end of the newhose. This creates a hose replacement rotation.6.3 Scalesplatform scales or load cells accurate to 1 %.6.4 Specimen Preparation Rooman enclosed a
22、rea wherethe test material is to be blown into the test chamber. This areais required to protect the blowing operation from wind orstrong air currents. Room geometry should provide adequateclearance around the test chamber and large enough not toinfluence the blowing stream from the hose.6.5 Hose No
23、zzle Standa hose stand on swivel casters thatholds the blowing hose at a fixed height of 36 to 48 in. (0.9 to1.2 m) and is on a swivel that allows the operator to swing thehose horizontally back and forth while slowly moving back-wards and forwards to fill the test chamber. A typical hosenozzle stan
24、d is shown in Fig. 1. Use of the hose stand isoptional.6.6 Moveable Test Chamber (Procedure A)a woodenopen container to collect the insulation. The chamber shallFIG. 1 Hose Nozzle StandC 1574 04 (2008)2have a minimum capacity of 20 ft3(0.57 m3) and have theminimum inside dimensions of 11 in. high by
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC157420042008STANDARDGUIDEFORDETERMININGBLOWNDENSITYOFPNEUMATICALLYAPPLIEDLOOSEFILLMINERALFIBERTHERMALINSULATIONPDF

链接地址:http://www.mydoc123.com/p-465171.html