ASTM C1570-2003 Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles(Air Permeability Method)《混凝土和粘土屋面瓦抗风性的标准试验方法(空气渗透率法)》.pdf
《ASTM C1570-2003 Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles(Air Permeability Method)《混凝土和粘土屋面瓦抗风性的标准试验方法(空气渗透率法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1570-2003 Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles(Air Permeability Method)《混凝土和粘土屋面瓦抗风性的标准试验方法(空气渗透率法)》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1570 03Standard Test Method forWind Resistance of Concrete and Clay Roof Tiles(Air Permeability Method)1This standard is issued under the fixed designation C 1570; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 The air permeability of tile roofing systems is a criticalfactor in determining the wind resistance of tile r
3、oofing asapplied to a roof. This Standard describes a procedure formeasuring the air permeability of clay and concrete tile andslate roof systems when applied to a small section of roof deckin accordance with the manufacturers instructions.1.2 This test procedure measures the air permeability of ala
4、id array of unsealed clay or concrete roof tiles or slates. Thetiles or slates shall have a thickness between18-in. (3-mm) and2-in. (51-mm).1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard t
5、o establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 43 Terminology of Structural Clay Products2C 67 Test Methods for Sampling and Testing Brick andStructural Clay Tile2C 140 Test Meth
6、ods of Sampling and Testing ConcreteMasonry Units2C 1167 Specification for Clay Roof Tiles2C 1492 Specification for Concrete Roof Tiles22.2 SBCCI Standard:SBCCI SSDT 11, SBCCI Test Standard for DeterminingWind Resistance of Concrete or Clay Roof Tiles3NOTE 1This standard is based on the Internationa
7、l Code CouncilsICC/SBCCI SSTD 11 and work derived from the tile industrys testingprograms completed in the Redland Wind Tunnel in the UK.2.3 ASCE Standard:ASCE 7, Minimum Design Loads for Buildings and OtherStructures43. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod refe
8、r to Terminology C 43, and Specifications C 1167and C 1492.4. Principle of the Test Method4.1 Air pressure is applied to the underside of an airpermeable assembly of a specified type of roofing elements.The difference in air pressure across the assembly and thevolume air flow rate are measured and u
9、sed to determine the airpermeability of the assembly.5. Significance and Use5.1 The air permeability of roofing systems constructedfrom discrete elements, as is the case for clay and concrete tileand slate roof systems, is a critical factor in determining thewind resistance of the roof system. The a
10、bility of the roofsystem to relieve wind-induced uplift pressures as a result ofthe overall air permeability of the roof assembly relates to theresistance of the roof system to damage induced by wind.5.2 Natural wind conditions differ with respect to intensity,duration, and turbulence; these conditi
11、ons are beyond themeans of this test method to simulate.6. Apparatus6.1 A plenum chamber is a rectangular box with a depth ofnot less than 1.64 ft (500 mm) or one-third of the least lateraldimension, whichever is the greater. The plenum chamber shallbe made airtight except for an open upper face to
12、receive amounting board or cover panel, a tapping for a pressuredifference gage (relative to atmospheric pressure) and a con-nection to an air delivery pipe. The tapping shall be positionedto avoid direct alignment with the air delivery pipe. The shapeand area of the mounting surface shall be capabl
13、e of accepting1This test method is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.06 on Roofing Tile .Current edition approved August 10, 2003. Published August 2003.2Annual Book of ASTM Standards, Vol 04.05.34Available f
14、rom The American Society of Civil Engineers (ASCE), 1801Alexander Bell Dr., Reston, VA 20191.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the number of test samples specified in 8.1 as a minimum. Aschematic of the air permeability
15、 apparatus is shown in Fig. 1.6.2 An airtight removable cover panel shall be securedairtight to the plenum chamber.6.3 An open face mounting board to receive the roofingsubstrate and test samples.6.4 A controllable air flow generator shall be capable ofcontinuously delivering air at a rate such that
16、 the upliftoverturning moment on the roofing elements induced by thepressure in the plenum chamber by the air flow is equal andopposite to the dead weight restoring moment.6.5 An airflow meter capable of measuring air volume flowrates in the delivery pipe and having an accuracy of 0.1 ft3/s(0.003 m3
17、/s) or better.6.6 A pressure difference measuring device (such as amanometer) connected to the inside and outside of the plenumchamber, capable of measuring a pressure difference of not lessthan 0.15 psi (1000 Pa).6.7 Airtight seals for pipe connections, mounting board andcover panels, and at joints
18、 and edges of the roofing assembly.6.8 A weighing device capable of measuring the deadweight of the roofing elements to the nearest 0.1 lbm (0.05 kg).7. Check on Air-tightness of the Apparatus7.1 Close the top of the plenum chamber by attaching andsealing the edges of the mounting board or cover pan
19、el so thatthe plenum chamber is air-tight except where connected to thedelivery pipe.7.2 Supply air from the airflow generator to induce apressure difference between the inside and outside of theplenum chamber at test pressure but not less than 10.5 lbf/ft2(500 Pa). The air tightness of the plenum c
20、hamber shall beconsidered satisfactory if this pressure difference is maintainedwith an air flow-rate not exceeding 0.15 ft3/s (0.004 m3/s).8. Test Specimen8.1 Select, at random, sufficient roofing elements and halfwidth elements, where appropriate, to assemble an array witha minimum of 4 unsealed e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC15702003STANDARDTESTMETHODFORWINDRESISTANCEOFCONCRETEANDCLAYROOFTILESAIRPERMEABILITYMETHOD 混凝土 粘土

链接地址:http://www.mydoc123.com/p-465162.html