ASTM C157 C157M-2008 Standard Test Method for Length Change of Hardened Hydraulic-Cement Mortar and Concrete《硬化水泥灰浆和混凝土长度变化的标准试验方法》.pdf
《ASTM C157 C157M-2008 Standard Test Method for Length Change of Hardened Hydraulic-Cement Mortar and Concrete《硬化水泥灰浆和混凝土长度变化的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C157 C157M-2008 Standard Test Method for Length Change of Hardened Hydraulic-Cement Mortar and Concrete《硬化水泥灰浆和混凝土长度变化的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 157/C 157M 08Standard Test Method forLength Change of Hardened Hydraulic-Cement Mortar andConcrete1This standard is issued under the fixed designation C 157/C 157M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers the
3、 determination of the lengthchanges that are produced by causes other than externallyapplied forces and temperature changes in hardened hydraulic-cement mortar and concrete specimens made in the laboratoryand exposed to controlled conditions of temperature andmoisture.1.2 The values stated in either
4、 SI units or inch-pound unitsare to be regarded separately as standard. An exception is withregard to sieve sizes and nominal size of aggregate, in whichthe SI values are the standard as stated in Specification E11.Within the text, the SI units are shown in brackets. The valuesstated in each system
5、may not be exact equivalents; therefore,each system shall be used independently of the other. Combin-ing values from the two systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresp
6、onsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 125 Terminology Relating to Concrete and ConcreteAggregatesC 143/C 143M Test Method for S
7、lump of Hydraulic-Cement ConcreteC 172 Practice for Sampling Freshly Mixed ConcreteC 192/C 192M Practice for Making and Curing ConcreteTest Specimens in the LaboratoryC 305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC 490 Practice for Use of Apparatus
8、for the Determinationof Length Change of Hardened Cement Paste, Mortar, andConcreteC511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and ConcretesC 596 Test Method for Drying Shrinkage of Mortar Con-taining Hydraulic Ceme
9、ntC 1347 Practice for Preparation and Dissolution of UraniumMaterials for AnalysisE11 Specification for Wire Cloth and Sieves for TestingPurposesE 337 Test Method for Measuring Humidity with a Psy-chrometer (the Measurement of Wet- and Dry-Bulb Tem-peratures)3. Terminology3.1 DefinitionsThe terms us
10、ed in this test method aredefined in Terminology C 125.3.2 Definitions of Terms Specific to This Standard:3.2.1 length change, nan increase or decrease in thelength of a test specimen that has been caused to change by anyfactor other than externally applied forces and temperaturechanges.4. Significa
11、nce and Use4.1 Measurement of length change permits assessment ofthe potential for volumetric expansion or contraction of mortaror concrete due to various causes other than applied force ortemperature change. This test method is particularly useful forcomparative evaluation of this potential in diff
12、erent hydraulic-cement mortar or concrete mixtures.4.2 This test method provides useful information for experi-mental purposes or for products that require testing undernonstandard mixing, placing, handling, or curing conditions,such as high product workability or different demolding times.Standard
13、conditions are described in 5.4.1.4.3 If conditions for mixing, curing, sampling, and storageother than specified in this test method are required, they shallbe reported but are not to be considered as standard conditions1This test method is under the jurisdiction of ASTM Committee C09 onConcrete an
14、d Concrete Aggregates and is the direct responsibility of SubcommitteeC09.68 on Volume Change.Current edition approved Oct. 1, 2008. Published November 2008. Originallyapproved in 1940. Last previous edition approved in 2006 as C 157/C 157M 06.2For referenced ASTM standards, visit the ASTM website,
15、www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Driv
16、e, PO Box C700, West Conshohocken, PA 19428-2959, United States.of this test method. Nonstandard conditions and the reasons fordeparture from standard conditions shall be reported clearlyand prominently with comparator values.5. Apparatus5.1 Molds and Length ComparatorThe molds for castingtest speci
17、mens and the length comparator for measuring lengthchange shall conform to the requirements of Practice C 490.5.2 TamperThe tamper shall be made of a nonabsorptive,nonabrasive material such as medium-hard rubber or seasonedoak wood rendered nonabsorptive by immersion for 15 min inparaffin at approxi
18、mately 392 F 200 C, and shall have across section of12 by 1.0 in. 13 by 25 mm and a convenientlength of about 6 in. 150 mm. The tamping face of the tampershall be flat and at right angles to the length of the tamper.5.3 Tamping RodThe tamping rod shall be a straight steelrod38 in. 10 mm in diameter
19、and not less than 10 in. 250mm in length, having at least the tamping end rounded to ahemispherical tip of the same diameter.5.4 Drying Room and ControlsA drying room with suit-able racks shall be provided when storing specimens in air. Theracks shall be designed for free circulation of air aroundsp
20、ecimens, except for necessary supports, and shall be sosituated with respect to the nearest wall or other obstructionthat air circulation is not restricted in the intervening space.The supports shall be horizontal and shall consist of twononabsorptive members not deeper than 1 in. 25 mm andhaving a
21、bearing area of not more than14 in. 6 mm in width.Conditioned air shall be circulated into and out of the room ina uniform manner so that the specified rate of evaporation isattained adjacent to all specimens.5.4.1 The air in the room shall be maintained at a tempera-ture of 73 6 3F236 2 C and a rel
22、ative humidity of 50 64 %. The air movement past all specimens shall be such thatthe rate of evaporation is 77 6 30-mL/24 h from an atmometeror 13 6 5-mL/24 h from a 400-mL Griffin low-form beakerfilled to34 in. 20 mm from the top. The temperature andrelative humidity of the air in the room shall be
23、 measured witheither a sling or Assmann psychrometer at least twice eachworking day. The psychrometer shall comply with Test MethodE 337, except that thermometers having an overall length of 10in. 250 mm and marked in subdivisions of 0.5 F 0.25 Care permitted. The room shall be equipped with a means
24、 ofmeasuring and recording wet- and dry-bulb temperaturescontinuously. Correction factors as indicated by the sling orAssmann psychrometer shall be applied to the recorded data.The rate of evaporation within the room shall be determineddaily by the use of the atmometer or by the loss of mass ofwater
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC157C157M2008STANDARDTESTMETHODFORLENGTHCHANGEOFHARDENEDHYDRAULICCEMENTMORTARANDCONCRETE 硬化 水泥 灰浆

链接地址:http://www.mydoc123.com/p-465158.html