ASTM C1550-2008 Standard Test Method for Flexural Toughness of Fiber Reinforced Concrete (Using Centrally Loaded Round Panel).pdf
《ASTM C1550-2008 Standard Test Method for Flexural Toughness of Fiber Reinforced Concrete (Using Centrally Loaded Round Panel).pdf》由会员分享,可在线阅读,更多相关《ASTM C1550-2008 Standard Test Method for Flexural Toughness of Fiber Reinforced Concrete (Using Centrally Loaded Round Panel).pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1550 08Standard Test Method forFlexural Toughness of Fiber Reinforced Concrete (UsingCentrally Loaded Round Panel)1This standard is issued under the fixed designation C 1550; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of flexuraltoughness of fiber-reinforced concrete expres
3、sed as energyabsorption in the post-crack range using a round panel sup-ported on three symmetrically arranged pivots and subjected toa central point load. The performance of specimens tested bythis method is quantified in terms of the energy absorbedbetween the onset of loading and selected values
4、of centraldeflection.1.2 This test method provides for the scaling of resultswhenever specimens do not comply with the target thicknessand diameter, as long as dimensions do not fall outside of givenlimits.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement
5、 are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitation
6、s prior to use.2. Referenced Documents2.1 ASTM Standards:2C 31/C 31M Practice for Making and Curing Concrete TestSpecimens in the FieldC 125 Terminology Relating to Concrete and ConcreteAggregatesC 670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction Materials3.
7、Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology C 125.3.2 Definitions of Terms Specific to This Standard:3.2.1 central deflectionthe net deflection at the center ofthe panel measured relative to a plane defined by the threepivots used to support the p
8、anel; this is a conditioned deflectionthat excludes extraneous deformations of the load train andlocal crushing of the panel at the point of load application andpoints of support.3.2.2 compliancea measure of the tendency of a structureto deflect under load, found as the inverse of stiffness ordeflec
9、tion divided by the corresponding load.3.2.3 load trainthose parts of a testing machine thatexperience load and undergo straining during a mechanicaltest, including the actuator, frame, support fixtures, load cell,and specimen.3.2.4 toughnessthe energy absorbed by the specimenequivalent to the area
10、under the load-deflection curve betweenthe onset of loading and a specified central deflection.4. Summary of Test Method4.1 Molded round panels of cast fiber-reinforced concrete orfiber-reinforced shotcrete are subjected to a central point loadwhile supported on three symmetrically arranged pivots.
11、Theload is applied through a hemispherical-ended steel pistonadvanced at a prescribed rate of displacement. Load anddeflection are recorded simultaneously up to a specified centraldeflection. The energy absorbed by the panel up to a specifiedcentral deflection is representative of the flexural tough
12、ness ofthe fiber-reinforced concrete panel.5. Significance and Use5.1 The post-crack behavior of plate-like, fiber-reinforcedconcrete structural members is well represented by a centrallyloaded round panel test specimen that is simply supported onthree pivots symmetrically arranged around its circum
13、ference.Such a test panel experiences bi-axial bending in response to acentral point load and exhibits a mode of failure related to thein situ behavior of structures. The post-crack performance ofround panels subject to a central point load can be representedby the energy absorbed by the panel up to
14、 a specified centraldeflection. In this test method, the energy absorbed up to aspecified central deflection is taken to represent the ability of afiber-reinforced concrete to redistribute stress following crack-ing.1This test method is under the jurisdiction of ASTM Committee C09 onConcrete and Con
15、crete Aggregates and is the direct responsibility of SubcommitteeC09.42 on Fiber-Reinforced Concrete.Current edition approved Oct. 1, 2008. Published October 2008. Originallyapproved in 2002. Last previous edition approved in 2005 as C 1550 05.2For referenced ASTM standards, visit the ASTM website,
16、www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Driv
17、e, PO Box C700, West Conshohocken, PA 19428-2959, United States.NOTE 1The use of three pivoted point supports in the test configura-tion results in determinate out-of-plane reactions prior to cracking,however the support reactions are indeterminate after cracking due to theunknown distribution of fl
18、exural resistance along each crack. There is alsoa change in the load resistance mechanism in the specimen as the testproceeds, starting with predominantly flexural resistance and progressingto tensile membrane action around the center as the imposed deflection isincreased. The energy absorbed up to
19、 a specified central deflection isrelated to the toughness of the material but is specific to this specimenconfiguration because it is also determined by the support conditions andsize of the specimen. Selection of the most appropriate central deflectionto specify depends on the intended application
20、 for the material. The energyabsorbed up to 5 mm central deflection is applicable to situations in whichthe material is required to hold cracks tightly closed at low levels ofdeformation. Examples include final linings in underground civil struc-tures such as railway tunnels that may be required to
21、remain water-tight.The energy absorbed up to 40 mm is more applicable to situations in thatthe material is expected to suffer severe deformation in situ (for example,shotcrete linings in mine tunnels and temporary linings in swellingground). Energy absorption up to intermediate values of central def
22、lectioncan be specified in situations requiring performance at intermediate levelsof deformation.5.2 The motivation for use of a round panel with threesupports is based on the within-batch repeatability found inlaboratory3and field experience.4The consistency of thefailure mode that arises through t
23、he use of three symmetricallyarranged support pivots results in low within-batch variabilityin the energy absorbed by a set of panels up to a specifiedcentral deflection. The use of round panels also eliminates thesawing that is required to prepare shotcrete beam specimens.5.3 The nominal dimensions
24、 of the panel are 75 mm inthickness and 800 mm in diameter. Thickness has been shownto strongly influence panel performance in this test, whilevariations in diameter have been shown to exert a minorinfluence on performance.5Correction factors are provided toaccount for actual measured dimensions.NOT
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC15502008STANDARDTESTMETHODFORFLEXURALTOUGHNESSOFFIBERREINFORCEDCONCRETEUSINGCENTRALLYLOADEDROUNDPANELPDF

链接地址:http://www.mydoc123.com/p-465090.html