ASTM C1522-2005(2013) Standard Test Method for Extensibility After Heat Aging of Cold Liquid-Applied Elastomeric Waterproofing Membranes《冷液弹性防水薄膜热老化后伸展性的标准试验方法》.pdf
《ASTM C1522-2005(2013) Standard Test Method for Extensibility After Heat Aging of Cold Liquid-Applied Elastomeric Waterproofing Membranes《冷液弹性防水薄膜热老化后伸展性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1522-2005(2013) Standard Test Method for Extensibility After Heat Aging of Cold Liquid-Applied Elastomeric Waterproofing Membranes《冷液弹性防水薄膜热老化后伸展性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1522 05 (Reapproved 2013)Standard Test Method forExtensibility After Heat Aging of Cold Liquid-AppliedElastomeric Waterproofing Membranes1This standard is issued under the fixed designation C1522; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes a laboratory procedure fordetermining extensibility
3、 for one- or two-component coldliquid-applied elastomeric waterproofing membranes.1.2 The values stated in SI units are to be regarded as thestandard. The values in parentheses are for information only.1.3 The committee with jurisdiction over this standard is notaware of any comparable standards pub
4、lished by other orga-nizations.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitatio
5、ns prior to use.2. Referenced Documents2.1 ASTM Standards:2C717 Terminology of Building Seals and SealantsC1250 Test Method for Nonvolatile Content of Cold Liquid-Applied Elastomeric Waterproofing MembranesC1375 Guide for Substrates Used in Testing Building Sealsand Sealants3. Terminology3.1 Definit
6、ionsRefer to Terminology C717 for definitionsof terms used in this standard.4. Comparison to Other Standards4.1 The committee with jurisdiction over this standard is notaware of any comparable standards published by other orga-nizations.5. Summary of Test Method5.1 This test method consists of prepa
7、ring three samples, foreach membrane to be tested, and extending after aging 14 daysat 70 6 2C (158 6 3.6F).6. Significance and Use6.1 This test method is used to determine a membranesability to bridge a crack that forms after the membrane hasbeen applied and allowed to cure.7. Apparatus7.1 Forced D
8、raft Oven, controlled to 70 6 2C (158 63.6F).7.2 Three Mortar Test Blocks, dimensions 12 76 152mm (12 36in.) nominal with 6 mm (14 in.) deep notch cutacross the width (see Fig. 1).7.3 Masking Tape.7.4 Sand.7.5 Wood Board, Steel Wedge, Hammer, and Wood Blades.7.6 Testing Machine, with tension grips c
9、apable of pulling ata rate of separation of 12.7 mm (0.5 in.)/min.7.7 Vernier Calipers.8. Conditioning/Mixing8.1 Unless otherwise specified by those authorizing the test,standard conditions are 23 6 1C (73.4 6 1.8F) and 50 6 5%relative humidity.8.2 Store all membrane materials to be tested in an un-
10、opened container at standard conditions for at least 24 h beforeany test specimens are prepared.8.3 Follow the manufacturers instructions for mixing andpreparing membrane materials for testing. Thoroughly stirone-component materials before using. Mix two-componentcompounds in the ratio recommended b
11、y the manufacturer. Ifrequired by the manufacturer, mix each component prior to thefinal mix.9. Procedure9.1 Prepare three test specimens for each membrane to betested as follows:1This test method is under the jurisdiction ofASTM Committee D08 on Roofingand Waterproofing and is the direct responsibi
12、lity of Subcommittee D08.22 onWaterproofing and Dampproofing Systems.Current edition approved May 1, 2013. Published May 2013. Originallyapproved in 2002. Last previous edition approved in 2005 as C152205. DOI:10.1520/C1522-05R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org,
13、orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States19.1.1 Cut each of
14、 the three mortar slabs crosswise in thecenter of the 152 mm (6 in.) length to a depth of 6 mm (14 in.),as shown in Fig. 1.NOTE 1Mortar substrates must be prepared according to GuideC1375.9.1.2 Measure the thickness of each block to the nearest0.025 mm (0.001 in.) on each side of the center notch, u
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC152220052013STANDARDTESTMETHODFOREXTENSIBILITYAFTERHEATAGINGOFCOLDLIQUIDAPPLIEDELASTOMERICWATERPROOFINGMEMBRANES

链接地址:http://www.mydoc123.com/p-464992.html